Clinically relevant finite element technique based protocol to evaluate growing rods for early onset scoliosis correction

被引:10
|
作者
Shekouhi, Niloufar [1 ]
Dick, David [1 ]
Baechle, Maxwell William [1 ]
Kaeley, Dilpreet Kaur [1 ]
Goel, Vijay K. [1 ]
Serhan, Hassan [2 ,3 ]
Rawlinson, Jeremy [4 ]
Shaw, Derek [5 ]
机构
[1] Univ Toledo, Engn Ctr Orthoped Res Excellence E CORE, Toledo, OH 43606 USA
[2] Univ Toledo, Dept Bioengn, Toledo, OH 43606 USA
[3] Univ Toledo, Dept Orthopaed Surg, Toledo, OH 43606 USA
[4] Medtronic Spine, Res & Technol, Memphis, TN USA
[5] DePuy Synthes Spine, Raynham, MA USA
来源
JOR SPINE | 2020年 / 3卷 / 03期
关键词
ASTM-F1717; Distraction; Finite Element Analysis; Scoliosis; Traditional Growing Rods (TGRs); SPINAL STABILIZATION DEVICES; ISO; 12189; STANDARD; PRECLINICAL EVALUATION; INTERNATIONAL STANDARDS; FIXATION SYSTEMS;
D O I
10.1002/jsp2.1119
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective The emergence of distraction-based growing rods has provided the means to reduce the progression of spinal deformity in early onset scoliosis (EOS). The current protocols for evaluating spinal implants (ie, ASTM-F1717 and ISO-12189) were developed for fusion/dynamic devices. These protocols do not feature long unsupported rod lengths subjected to distraction. Due to the unsuitability of the existing guidelines for the evaluation of growing rods, a new distraction-based finite element protocol is presented herein for the first time. Method A vertebrectomy (VO) model from current protocols was modified to accommodate multi-spinal segments (ie, MS model) in which springs with appropriate stiffness were simulated in between the plastic blocks. To assess the efficacy of the protocol, two different computational studies were conducted: (a) compression-bending (MS-CB) with no distraction, and (b) distraction followed by compression-bending (MS-D + CB). In each study, the model with no axial connector (rods-only) was modified to include a) 80-mm long tandem (LT) connectors, and b) side-by-side (SBS) connectors. Stiffness and yield loads were calculated as per ASTM-F1717 guidelines and compared with the corresponding VO models with no distraction. In the MS-D + CB models, distraction was applied at the top block, stretching the spring-block construct in a simulation of scoliosis surgery prior to locking the construct at the connector-rods' interface. Results MS-CB models predicted higher stiffness and yield loads, compared to the VO models. The locking mechanism produced pre-existing stresses on the rod-connector interface, which caused a shift in the location of high-stress regions to the distraction site. Distraction led to a decrease in the construct's stiffness and yield load. Discussion The proposed protocol enables the simulation of clinical parameters that are not feasible in the F1717 models and predicted stress patterns in the hardware consistent with observed clinical failures.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Growing rods in early-onset scoliosis
    Berger-Groch, Josephine
    Stuecker, Ralf
    [J]. SPINE JOURNAL, 2016, 16 (09): : E601 - E602
  • [2] Complications of Fusionless Correction of Early Onset Scoliosis Using Dual Growing Rods
    Nikouei, Farshad
    Ghandhari, Hasan
    Ameri, Ebrahim
    Mahdavi, Seyed Mani
    Ameri, Maryam
    Safdari, Farshad
    [J]. ARCHIVES OF IRANIAN MEDICINE, 2018, 21 (12) : 595 - 599
  • [3] Growing rods in Early Onset Scoliosis: The current scenario
    Mehta, Jwalant S.
    Tognini, Martina
    Hothi, Harry
    [J]. JOURNAL OF ORTHOPAEDICS, 2023, 42 : 63 - 69
  • [4] Advances in growing rods treatment for early onset scoliosis
    Bekmez, Senol
    Dede, Ozgur
    Yazici, Muharrem
    [J]. CURRENT OPINION IN PEDIATRICS, 2017, 29 (01) : 87 - 93
  • [5] Magnetically controlled growing rods in early-onset scoliosis
    Meyer, Charlotte Sommer
    Rickers, Kresten
    Eiskjaer, Soren Peter
    [J]. DANISH MEDICAL JOURNAL, 2022, 69 (04):
  • [6] Dual Growing Rods and the Apical Control Technique for Treating Congenital Early-Onset Scoliosis
    Wang, Shengru
    Zhao, Yiwei
    Du, You
    Yang, Yang
    Lin, Guanfeng
    Shen, Jianxiong
    Zhao, Yu
    Wu, Nan
    Zhuang, Qianyu
    Zhang, Jianguo
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2024, 106 (04): : 304 - 314
  • [7] Rib-Based Anchors for Growing Rods in the Treatment of Early-Onset Scoliosis
    Miller, Daniel J.
    Vitale, Michael G.
    [J]. OPERATIVE TECHNIQUES IN ORTHOPAEDICS, 2016, 26 (04) : 241 - 246
  • [8] Early experience of MAGEC magnetic growing rods in the treatment of early onset scoliosis
    Hickey B.A.
    Towriss C.
    Baxter G.
    Yasso S.
    James S.
    Jones A.
    Howes J.
    Davies P.
    Ahuja S.
    [J]. European Spine Journal, 2014, 23 (Suppl 1) : S61 - S65
  • [9] Preliminary Results of Magnetically Controlled Growing Rods for Early Onset Scoliosis
    Ridderbusch, Karsten
    Rupprecht, Martin
    Kunkel, Philip
    Hagemann, Christian
    Stuecker, Ralf
    [J]. JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2017, 37 (08) : E575 - E580
  • [10] Standard and magnetically controlled growing rods for the treatment of early onset scoliosis
    Helenius, Ilkka J.
    [J]. ANNALS OF TRANSLATIONAL MEDICINE, 2020, 8 (02)