Fetal MRI of the cardiovascular system: role of steady-state free precession sequences for the evaluation of normal and pathological appearances

被引:0
|
作者
Manganaro, L. [1 ]
Savelli, S. [1 ]
Di Maurizio, M. [1 ]
Francioso, A. [1 ]
Fierro, F. [1 ]
Tomei, A. [1 ]
Coratella, F. [1 ]
Ballesio, L. [1 ]
Ventriglia, F. [2 ]
机构
[1] Univ Roma La Sapienza, Dipartimento Sci Radiol, I-00161 Rome, Italy
[2] Univ Roma La Sapienza, Dipartimento Pediat, Serv Cardiol Pediat, I-00161 Rome, Italy
来源
RADIOLOGIA MEDICA | 2009年 / 114卷 / 06期
关键词
Fetal heart; Fetal MRI; Congenital heart disease; Cardiac malformations; Prenatal diagnosis; CONGENITAL HEART-DISEASE; ULTRASOUND; PREGNANCY;
D O I
10.1007/s11547-009-0419-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose. This study aimed to evaluate the feasibility of fetal magnetic resonance imaging (MRI) with steady-state free precession (SSFP) sequences to visualise the normal and pathological appearances of the cardiovascular system. Materials and methods. This is a prospective observational study of 83 pregnant women who underwent fetal cardiac MRI: 43 patients (cases) had echocardiographic suspicion of congenital heart disease; 40 patients (controls) did not. Fetal cardiac MRI consisted of a static phase with multiplanar SSFP sequences and a dynamic phase with real-time SSFP sequences. Two radiologists evaluated the diagnostic quality of the SSFP images in both the controls and cases, the MRI morphological and functional features in the controls and the MRI signs of congenital heart disease in the cases. Results. In both groups, SSFP sequences produced good-quality MR images and good visualisation of morphological features. Functional data appeared to be unavailable due to the current small temporal resolution and the technical impossibility of fetal cardiac triggering. MRI detected direct signs of congenital heart disease in 21 fetuses, indirect signs in six and both signs in 15. Conclusions. SSFP sequences are effective in demonstrating the morphological features of the cardiovascular system, whereas dynamic SSFP cine-MRI sequences may provide adjunctive albeit suboptimal functional information.
引用
收藏
页码:852 / 870
页数:19
相关论文
共 50 条
  • [41] Usefulness of India Ink Artifact in Steady-State Free Precession Pulse Sequences for Detection and Quantification of Intramyocardial Fat
    Aquaro, Giovanni Donato
    Todiere, Giancarlo
    Strata, Elisabetta
    Barison, Andrea
    Di Bella, Gianluca
    Lombardi, Massimo
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 40 (01) : 126 - 132
  • [42] Optimized spectrally selective steady-state free precession sequences for cartilage imaging at ultra-high fields
    O. Bieri
    T. C. Mamisch
    S. Trattnig
    O. Kraff
    M. E. Ladd
    K. Scheffler
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2008, 21
  • [43] Fourier Decomposition Pulmonary MRI Using a Variable Flip Angle Balanced Steady-State Free Precession Technique
    Corteville, D. M. R.
    Kjorstad, A.
    Henzler, T.
    Zoellner, F. G.
    Schad, L. R.
    MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (05) : 1999 - 2004
  • [44] Comparison of 3D segmented gradient-echo and steady-state free precession coronary MRI sequences in patients with coronary artery disease
    Ozgun, M
    Hoffmeier, A
    Kouwenhoven, M
    Botnar, RM
    Stuber, M
    Scheld, HH
    Manning, WJ
    Heindel, W
    Maintz, D
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 185 (01) : 103 - 109
  • [45] Systematic investigation of balanced steady-state free precession for functional MRI in the human visual cortex at 3 tesla
    Zhong, Kai
    Leupold, Jochen
    Hennig, Juergen
    Speck, Oliver
    MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (01) : 67 - 73
  • [46] Principles and applications of the balanced steady-state free precession sequence in small animal low-field MRI
    Ricciardi, Mario
    VETERINARY RESEARCH COMMUNICATIONS, 2018, 42 (01) : 65 - 86
  • [47] High spatial resolution brain functional MRI using submillimeter balanced steady-state free precession acquisitiona)
    Wu, Pei-Hsin
    Tsai, Ping-Huei
    Wu, Ming-Long
    Chuang, Tzu-Chao
    Shih, Yi-Yu
    Chung, Hsiao-Wen
    Huang, Teng-Yi
    MEDICAL PHYSICS, 2013, 40 (12)
  • [48] Principles and applications of the balanced steady-state free precession sequence in small animal low-field MRI
    Mario Ricciardi
    Veterinary Research Communications, 2018, 42 : 65 - 86
  • [49] EVALUATION OF COMPLEX CYSTIC MASSES OF THE BRAIN - VALUE OF STEADY-STATE FREE-PRECESSION MR IMAGING
    TIEN, RD
    MACFALL, J
    HEINZ, R
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 159 (05) : 1049 - 1055
  • [50] Steady-state free precession sequences in myocardial first-pass perfusion MR imaging: comparison with TurboFLASH imaging
    Hunold, P
    Maderwald, S
    Eggebrecht, H
    Vogt, FM
    Barkhausen, J
    EUROPEAN RADIOLOGY, 2004, 14 (03) : 409 - 416