Analysis of windbreaker combinations on steam power plant natural draft dry cooling towers

被引:27
|
作者
Zavaragh, Hadi Ghasemi [1 ]
Ceviz, Mehmet Akif [1 ]
Tabar, Mohammed Taghi Shervani [2 ]
机构
[1] Ataturk Univ, Fac Engn, Dept Mech Engn, TR-25240 Erzurum, Turkey
[2] Univ Tabriz, Dept Mech Engn, Tabriz, Iran
关键词
Cooling tower; Windbreaker; PERFORMANCE; WIND; EFFICIENCY; SYSTEM;
D O I
10.1016/j.applthermaleng.2016.01.103
中图分类号
O414.1 [热力学];
学科分类号
摘要
Performance of natural draft dry cooling towers is significantly affected when the wind velocity is higher than a critical level according to their design and geometry. During this type of conditions, global electricity generation of power plants using especially dry type cooling towers is substantially reduced, up to as high as 40%. In order to decrease the reduction in electricity generation of power plants, it is possible to study on the dimensions of the cooling towers. Additionally, using different types of windbreakers can reduce the effects of unfavorable operating conditions. However, the direction of the wind changes with the seasons although the prevailing wind direction is nearly the same. In this study, internal flat and combination of internal flat-external rounded windbreakers have been analyzed by using the computational fluid dynamics approach. The combination of windbreakers, which is able to move axially around the cooling tower, has been propounded to arrange the flow characteristics during the windy days. The studies on the windbreakers in the literature have been aimed to decrease the negative effects of the wind; however, the design in this study provides also an increase in the air mass flowrate due to the momentum effect of the wind. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:550 / 559
页数:10
相关论文
共 50 条
  • [1] Analysis of Environmental Impact Factors of Natural Draft Cooling Towers in Power Plant
    Ding, Feng
    Bo, Xin
    [J]. ADVANCES IN ENVIRONMENTAL TECHNOLOGIES, PTS 1-6, 2013, 726-731 : 1436 - 1440
  • [2] Performance improvement of natural draft dry cooling system by interior and exterior windbreaker configurations
    Chen, Lei
    Yang, Lijun
    Du, Xiaoze
    Yang, Yongping
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2016, 96 : 42 - 63
  • [3] MINIMUM SIZE OF NATURAL-DRAFT DRY COOLING TOWERS FOR LARGE POWER-PLANTS
    MOORE, FK
    [J]. MECHANICAL ENGINEERING, 1973, 95 (06) : 61 - 61
  • [4] CFD analysis of pre-cooling water spray system in natural draft dry cooling towers
    Xia, Lin
    Gurgenci, Hal
    Liu, Deyou
    Guan, Zhiqiang
    Zhou, Ling
    Wang, Pei
    [J]. APPLIED THERMAL ENGINEERING, 2016, 105 : 1051 - 1060
  • [5] Factors Analysis of Environmental Effect of Natural Draft Cooling Towers in Burning Coal Plant
    Ding Feng
    Xing Kejia
    [J]. PROGRESS IN ENVIRONMENTAL SCIENCE AND TECHNOLOGY, VOL III: PROCEEDINGS OF THE 2011 INTERNATIONAL SYMPOSIUM ON ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2011, : 416 - 420
  • [6] The performance of natural draft dry cooling towers under crosswind: CFD study
    Al-Waked, R
    Behnia, M
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2004, 28 (02) : 147 - 161
  • [7] The effect of windbreak walls on the thermal performance of natural draft dry cooling towers
    Al-Waked, R
    Behnia, M
    [J]. HEAT TRANSFER ENGINEERING, 2005, 26 (08) : 50 - 62
  • [8] MINIMUM SIZE OF LARGE DRY COOLING TOWERS WITH COMBINED MECHANICAL AND NATURAL DRAFT
    MOORE, FK
    [J]. JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1973, 95 (03): : 383 - 389
  • [9] The influence of windbreak wall orientation on the cooling performance of small natural draft dry cooling towers
    Lu, Yuanshen
    Gurgenci, Hal
    Guan, Zhiqiang
    He, Suoying
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2014, 79 : 1059 - 1069
  • [10] Pre-cooling with Munters media to improve the performance of Natural Draft Dry Cooling Towers
    He, Suoying
    Gurgenci, Hal
    Guan, Zhiqiang
    Alkhedhair, Abdullah M.
    [J]. APPLIED THERMAL ENGINEERING, 2013, 53 (01) : 67 - 77