Shear Transfer Capacity of Angle Connectors in U-Shaped Composite Girder: Experimental and Numerical Study

被引:12
|
作者
Liu, Yong [1 ]
Guo, Lanhui [2 ]
Qu, Bing [3 ]
机构
[1] Hefei Univ Technol, Coll Civil Engn, Hefei 230009, Peoples R China
[2] Harbin Inst Technol, Sch Civil Engn, Harbin 150090, Peoples R China
[3] Calif Polytech State Univ San Luis Obispo, Dept Civil & Environm Engn, San Luis Obispo, CA 93407 USA
基金
国家重点研发计划;
关键词
Angle connector; Push-out tests; U-shaped composite girder; Slip;
D O I
10.1061/(ASCE)ST.1943-541X.0002984
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This research investigates the shear resistance of steel angle connectors welded to the webs of U-shaped steel-concrete composite girders. First, push-out tests were conducted on the experimental specimens in which the design parameters included the thickness of the angles, the concrete compressive strength, and whether or not foam blocks were attached to the ends of the angles. The test results showed that the slip capacities of the steel angle connectors exceeded 6 mm, for which the steel angle connectors can be categorized as a ductile shear connector. Finite-element (FE) models were then developed for each specimen. After the FE models were validated by the test results of the experimental specimens, the influences of different design parameters on the shear resistance of the angle connectors were investigated by parametric analyses. Further, based on the results from the parametric analyses, an empirical design model was developed and found to provide acceptable predictions for the shear resistance of the angle connector. (C) 2021 American Society of Civil Engineers.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Performance of angle shear connectors for U-shaped steel concrete infilled composite beams
    Haroon, Muhammad
    Lee, Hee-Du
    Shin, Kyung-Jae
    Woo, Jong-Hun
    Lee, Jun- Seop
    HELIYON, 2024, 10 (03)
  • [2] Push-out tests of shear connectors in U-shaped steel-concrete composite girder
    Liu, Yong
    Guo, Lanhui
    Shi, Jun
    Wang, Jingfeng
    STRUCTURES, 2021, 31 : 769 - 780
  • [3] Low cost composite slab with U-shaped bolt as shear connectors
    Yamada, Takeshi
    Numata, Katsu
    Okamoto, Yasuhiro
    Kubota, Aklra
    R and D: Research and Development Kobe Steel Engineering Reports, 2003, 53 (01): : 37 - 42
  • [4] Experimental and Numerical Investigation on the Ultimate Vertical Bearing Capacity of U-Shaped Girder with Damaged Web
    Zhang, Jingfeng
    Jing, Yuan
    Li, Pandao
    Han, Wanshui
    Zhang, Nan
    Zhou, Yunlai
    SENSORS, 2019, 19 (17)
  • [5] Interfacial shear resistance of angle shear connectors welded to concrete filled U-shaped CFS beam
    Oh, Hyoung Seok
    Shin, Hyeongyeop
    Ju, Youngkyu
    Kang, Thomas H. -K.
    STEEL AND COMPOSITE STRUCTURES, 2022, 43 (03): : 311 - 325
  • [6] Experimental investigation on the flexural behavior of steel-concrete composite beams with U-shaped steel girders and angle connectors
    Liu, Yong
    Guo, Lanhui
    Qu, Bing
    Zhang, Sumei
    ENGINEERING STRUCTURES, 2017, 131 : 492 - 502
  • [7] Shear Capacity of C-Shaped and L-Shaped Angle Shear Connectors
    Tahmasbi, Farzad
    Maleki, Shervin
    Shariati, Mahdi
    Sulong, N. H. Ramli
    Tahir, M. M.
    PLOS ONE, 2016, 11 (08):
  • [8] Experimental and analytical behavior of a prestressed U-shaped girder bridge
    Wu, Xun
    Li, Hui
    STRUCTURAL ENGINEERING AND MECHANICS, 2017, 61 (03) : 427 - 436
  • [9] Behavior of shear connection in web-embedded U-shaped steel-concrete composite beams: Experimental and numerical study
    Yan, Wenxu
    Yang, Yuanlong
    Lou, Guobiao
    Chen, Yohchia Frank
    ENGINEERING STRUCTURES, 2025, 332
  • [10] Bearing Capacity of Perfobond Rib Shear Connectors in Composite Girder Bridges
    Su, Qingtian
    Yang, Guotao
    Bradford, Mark A.
    JOURNAL OF BRIDGE ENGINEERING, 2016, 21 (04)