Performance of angle shear connectors for U-shaped steel concrete infilled composite beams

被引:0
|
作者
Haroon, Muhammad [1 ]
Lee, Hee-Du [1 ]
Shin, Kyung-Jae [2 ]
Woo, Jong-Hun [2 ]
Lee, Jun- Seop [1 ]
机构
[1] Kyungpook Natl Univ, Reg Ctr Land Infrastruct & Transport Technol, Daegu 41566, South Korea
[2] Kyungpook Natl Univ, Sch Architecture, Daegu 41566, South Korea
关键词
Angle shear connectors; Pushout tests; Composite members; Infilled-type; STATIC BEHAVIOR; CHANNEL; STRENGTH;
D O I
10.1016/j.heliyon.2024.e25119
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The current design codes i.e. AISC 360-16, CSA-S16-19, EC-04 etc. provide empirical relationships to estimate the capacity of shear connectors which were developed based on pushout tests of headed studs and channels connectors in exposed type sections. Therefore, these equations may result inaccurate predictions for strength of connectors in infilled-type sections. This study presents a detailed experimental study investigating the performance of angle connectors in composite sections. The testing program consisted two series of pushout tests. A total of 36 specimens were tested, considering the influence of several important parameters i.e. the length (Lc), height (hc), and web-thickness (tw) of angle connector, length of the weld (w) and the direction of shear connector (forward/backward) etc. The tests results demonstrated that with increasing connector height hs, and thickness, the maximum load Pmax and slip delta u were increased. The connector direction didn't change much the load-slip behavior. The prediction accuracy of the existing shear capacity models was evaluated by comparing the predictions with experimental results. The current equations were noticed to be highly inconsistent in predicting the shear capacity of angle connectors, especially in case of infilled type sections. When the entire length of connector was taken as the effective length, the models overestimated the shear capacity. While in case when the welding length was taken as effective length in calculations, the models underestimated the shear strength of angle connectors.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] Experimental investigation on the flexural behavior of steel-concrete composite beams with U-shaped steel girders and angle connectors
    Liu, Yong
    Guo, Lanhui
    Qu, Bing
    Zhang, Sumei
    [J]. ENGINEERING STRUCTURES, 2017, 131 : 492 - 502
  • [2] Design Methodology of U-Shaped Infilled Composite Beams with Angled Shear Connectors Using Finite Element Analysis
    Lee, Jun-Seop
    Woo, Jong-Hun
    Shin, Kyung-Jae
    Lee, Hee-Du
    [J]. BUILDINGS, 2023, 13 (09)
  • [3] Influence of partial shear connection on the behaviour of U-shaped steel concrete beams with L-shaped shear connectors
    Lepourry-Nicollet, Clemence
    Heng, Piseth
    Somja, Hugues
    Palas, Franck
    [J]. ENGINEERING STRUCTURES, 2023, 278
  • [4] Flexural Behavior of U-shaped Steel-concrete Composite Beams with Steel-bars Truss Deck in Different Shear Connectors
    Xu X.
    Cheng R.
    Liu J.
    Cui J.
    Huang Z.
    [J]. Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2022, 49 (01): : 42 - 50
  • [5] Shear Behavior of U-Shaped Steel–Concrete Composite Beams with Positive and Negative Loading
    Yukun Zhao
    Zhenbao Li
    Hua Ma
    Jiping Kan
    Nana Zhang
    [J]. International Journal of Civil Engineering, 2022, 20 : 1229 - 1246
  • [6] Push-out tests of shear connectors in U-shaped steel-concrete composite girder
    Liu, Yong
    Guo, Lanhui
    Shi, Jun
    Wang, Jingfeng
    [J]. STRUCTURES, 2021, 31 : 769 - 780
  • [7] Shear Behavior of U-Shaped Steel-Concrete Composite Beams with Positive and Negative Loading
    Zhao, Yukun
    Li, Zhenbao
    Ma, Hua
    Kan, Jiping
    Zhang, Nana
    [J]. INTERNATIONAL JOURNAL OF CIVIL ENGINEERING, 2022, 20 (10) : 1229 - 1246
  • [8] Deformation calculation of composite beams with concrete and prestressed U-shaped steel
    Yu, Jian-Jun
    Wang, Lian-Guang
    Huo, Jun-Hua
    [J]. Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2012, 44 (SUPPL.1): : 218 - 221
  • [9] Interfacial shear resistance of angle shear connectors welded to concrete filled U-shaped CFS beam
    Oh, Hyoung Seok
    Shin, Hyeongyeop
    Ju, Youngkyu
    Kang, Thomas H. -K.
    [J]. STEEL AND COMPOSITE STRUCTURES, 2022, 43 (03): : 311 - 325
  • [10] Flexural behavior of steel-concrete composite beams with U-shaped steel girders
    Liu, Y.
    Guo, L. H.
    Li, Z. G.
    [J]. PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON ADVANCES IN STEEL-CONCRETE COMPOSITE STRUCTURES (ASCCS 2018), 2018, : 161 - 167