Localization Accuracy of Partial Discharges in Power Transformers

被引:0
|
作者
Win, Su Su [1 ]
Adam, Benjamin [2 ]
Tenbohlen, Stefan [2 ]
机构
[1] Minist Educ, Singapore Myanmar Vocat Training Inst, Yangon, Myanmar
[2] Univ Stuttgart, Inst Power Transmiss & High Voltage Technol, Stuttgart, Germany
关键词
power transformer; partial discharge; acoustic; electrical method; time of flight; UHF; PD-SOURCES;
D O I
暂无
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
Power transformers belong to the most expensive and strategically important components of any power generation, transmission and distribution system. Therefore their reliability is of key importance. An increased electrical field in a region of weak insulation can generate permanent partial discharge activity (PD) in the insulating system which may finally lead to a complete electrical breakdown. Due to the high safety factor of the design, dangerous defects normally need some time to cause an alarm or fatal failure of the transformer. Defects caused by electrical stress are detectable by sensitive PD measurements [1]. It is generally accepted that PD detection using electrical and/or acoustic techniques, is one of the most effective diagnostic method to reveal local PD defects [2]. Although PD measurement is suitable to detect local defects, the localization of PD-sources in the large power transformer is still a challenge for all testing engineers. All PD-sources hidden deep in the insulating system, which are the most dangerous one, are not detectable in a correct way at bushings due to the attenuation and reflection phenomena on the way through the capacitive and inductive network of the insulating system of the transformer [1]. To locate PDs in power transformers effectively and quickly with the best accuracy, to locate more than one PD source in a single power transformer by analyzing several single-shot signals and to investigate the effects of noise (corona) on acoustic localization are the motivation of this study. They will be implemented in it.
引用
收藏
页码:197 / 200
页数:4
相关论文
共 50 条
  • [21] METHODOLOGY FOR THE DETECTION OF PARTIAL DISCHARGES IN POWER TRANSFORMERS USING THE ACOUSTIC METHOD
    Azevedo, C. H. B.
    Marques, A. P.
    Ribeiro, C. J.
    [J]. EUROCON 2009: INTERNATIONAL IEEE CONFERENCE DEVOTED TO THE 150 ANNIVERSARY OF ALEXANDER S. POPOV, VOLS 1- 4, PROCEEDINGS, 2009, : 618 - 621
  • [22] Anusual Application of Partial Discharges to Diagnose of High Voltage Power Transformers
    Gacek, Z.
    Szadkowski, M.
    Malitowski, G.
    Witos, F.
    Olszewska, A.
    [J]. ACTA PHYSICA POLONICA A, 2011, 120 (04) : 609 - 615
  • [23] Identification of Partial Discharges in Power Transformers: An Approach Driven by Practical Experience
    Ganeshan, S.
    Murugesan, J.
    Cavallini, A.
    Negri, F.
    Valecillos, B.
    Piovan, U.
    [J]. IEEE ELECTRICAL INSULATION MAGAZINE, 2017, 33 (05) : 23 - 31
  • [24] Investigation of Partial Discharges within Power Oil Transformers by Acoustic Emission
    Witos, Franciszek
    Olszewska, Aneta
    [J]. ENERGIES, 2023, 16 (09)
  • [25] STATIC ELECTRIFICATION AND PARTIAL DISCHARGES INDUCED BY OIL FLOW IN POWER TRANSFORMERS
    PEYRAQUE, L
    BOISDON, C
    BEROUAL, A
    BURET, F
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 1995, 2 (01) : 40 - 45
  • [26] LOCATING PARTIAL DISCHARGES IN TRANSFORMERS AND REACTORS
    TAN, TT
    [J]. BROWN BOVERI REVIEW, 1972, 59 (08): : 399 - &
  • [27] Acoustic Diagnosis of Partial Discharges in Transformers
    Huang Shan
    Liu Hongjing
    Qin Huan
    Qiu Shou
    Jian Wei
    Miao Wang
    Wu Linlin
    Liu Kewen
    Wu Guoxin
    Li Min
    [J]. 2020 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (2020 IEEE CEIDP), 2020, : 556 - 559
  • [28] Application of Pathfinding Algorithms in Partial Discharge Localization in Power Transformers
    Beura, Chandra Prakash
    Wolters, Jorim
    Tenbohlen, Stefan
    [J]. SENSORS, 2024, 24 (02)
  • [29] Optimisation of a Sensor for Onsite Detection of Partial Discharges in Power Transformers by the UHF Method
    Lopez-Roldan, J.
    Tang, T.
    Gaskin, M.
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2008, 15 (06) : 1634 - 1639
  • [30] Fiber Fabry-Perot sensors for detection of partial discharges in power transformers
    Yu, B
    Kim, DW
    Deng, JD
    Xiao, H
    Wang, A
    [J]. APPLIED OPTICS, 2003, 42 (16) : 3241 - 3250