Quantification of palm oil bioactive compounds by ultra-high-performance supercritical fluid chromatography and chemometrics

被引:4
|
作者
de Souza Guedes, Luciana [1 ]
Santana, Cesar Costapinto [1 ]
Rutledge, Douglas Neil [2 ,3 ]
Pinto, Licarion [4 ]
Jardim, Isabel Cristina Sales Fontes [5 ]
de Melo, Lucilia Vilela [5 ]
Beppu, Marisa Masumi [1 ]
Breitkreitz, Marcia Cristina [5 ]
机构
[1] Univ Estadual Campinas, Sch Chem Engn, Ave Albert Einstein 500, BR-13083852 Campinas, SP, Brazil
[2] Univ Paris Saclay, INRAE, AgroParisTech, UMR SayFood, Paris, France
[3] Charles Sturt Univ, Natl Wine & Grape Ind Ctr, Wagga Wagga, NSW, Australia
[4] Univ Fed Pernambuco, Dept Fundamental Chem, Recife, PE, Brazil
[5] Univ Estadual Campinas, Inst Chem, Campinas, Brazil
来源
关键词
carotenoids; coenzyme Q10; MCR‐ ALS; palm oil; UHPSFC; MULTIVARIATE CURVE RESOLUTION; QUANTITATIVE-ANALYSIS; MINOR COMPONENTS; MCR-ALS; CAROTENOIDS; LIQUID; HPLC; CALIBRATION; EXTRACTION; IDENTIFICATION;
D O I
10.1002/cjce.23969
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Lycopene, beta-carotene, coenzyme Q10, and lutein are minor constituents of palm oil that are removed during biodiesel production to produce light-coloured oils. With the aim to investigate the recovery of these valuable compounds, a separation method was developed to quantify carotenoids and coenzyme Q10 in palm oil by ultra-high-performance supercritical fluid chromatography. Due to the presence of interferents, different clean-up procedures were evaluated; however, these approaches were ineffective and the separation method was developed without this step. The chemometric method multivariate curve resolution-alternating least squares was employed to properly quantify lycopene, beta-carotene, and coenzyme Q10 in the presence of interferents. Lutein was sufficiently resolved to be quantified by a univariate method. Lycopene concentration was below the limit of quantification 3.12 mu g/mL (3.12 x 10(-3) kg/m(3)). Beta-carotene concentration was determined as being 183.48 +/- 1.66 mu g/mL (183.48 +/- 1.66 x 10(-3) kg/m(3)). Coenzyme Q10 concentration was lower than the limit of detection 4.22 mu g/mL (4.22 x 10(-3) kg/m(3)) and lutein concentration 9.24 mu g/mL (9.24 x 10(-3) kg/m(3)) was below the limit of quantification. The study showed the analytical challenges associated with the separation and quantification of minor constituents of a highly complex matrix such as palm oil and demonstrated that the recovery of beta-carotene could be economically viable due to its wide range of application in industry.
引用
收藏
页码:S629 / S644
页数:16
相关论文
共 50 条
  • [21] Comparison of ultra-high performance supercritical fluid chromatography and ultra-high performance liquid chromatography for the separation of spirostanol saponins
    Zhu, Ling-ling
    Zhao, Yang
    Xu, Yong-wei
    Sun, Qing-long
    Sun, Xin-guang
    Kang, Li-ping
    Yan, Ren-yi
    Zhang, Jie
    Liu, Chao
    Ma, Bai-ping
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2016, 120 : 72 - 78
  • [22] Comparative separation of chiral compounds by supercritical fluid chromatography and high performance liquid chromatography
    Zhang Jing
    Chen Xiaodong
    Li Liqun
    He Jianfeng
    Fan Jun
    Zhang Weiguang
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2016, 34 (03) : 321 - 326
  • [23] Generic chiral method development in supercritical fluid chromatography and ultra-performance supercritical fluid chromatography
    De Klerck, Katrijn
    Heyden, Yvan Vander
    Mangelings, Debby
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1363 : 311 - 322
  • [24] Separation of crude palm oil components by semipreparative supercritical fluid chromatography
    Choo, YM
    Ma, AN
    Yahaya, H
    Yamauchi, Y
    Bounoshita, M
    Saito, M
    JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 1996, 73 (04) : 523 - 525
  • [25] Method development for the analysis of bioactive and minor compounds from vegetable oil by supercritical fluid chromatography (SFC)
    Duval, J.
    Lesellier, E.
    PLANTA MEDICA, 2016, 82
  • [26] Rapid Simultaneous Analysis of Ten Biogenic Amines in Aquatic Products by Ultra-high-performance Supercritical Fluid Chromatography Combined with Mass Spectrometry
    Yingqi Du
    Haiqing Tang
    Changrong Ou
    Caiye Wu
    Zuman Chen
    Food Analytical Methods, 2023, 16 : 206 - 214
  • [27] An alternative strategy based on ultra-high-performance supercritical fluid chromatography for full monosaccharide compositional analysis of polysaccharides in Schisandra chinensis fruits
    Gao, Jia-Ning
    Li, Xin
    Liang, Jun
    Kuang, Hai-Xue
    Xia, Yong-Gang
    JOURNAL OF SEPARATION SCIENCE, 2023, 46 (08)
  • [28] Rapid Simultaneous Analysis of Ten Biogenic Amines in Aquatic Products by Ultra-high-performance Supercritical Fluid Chromatography Combined with Mass Spectrometry
    Du, Yingqi
    Tang, Haiqing
    Ou, Changrong
    Wu, Caiye
    Chen, Zuman
    FOOD ANALYTICAL METHODS, 2023, 16 (01) : 206 - 214
  • [29] The Way to Ultrafast, High-Throughput Enantioseparations of Bioactive Compounds in Liquid and Supercritical Fluid Chromatography
    Ismail, Omar H.
    Felletti, Simona
    De Luca, Chiara
    Pasti, Luisa
    Marchetti, Nicola
    Costa, Valentina
    Gasparrini, Francesco
    Cavazzini, Alberto
    Catani, Martina
    MOLECULES, 2018, 23 (10):
  • [30] Enantioselective separation of biologically active basic compounds in ultra-performance supercritical fluid chromatography
    Geryk, Radim
    Kalikova, Kveta
    Schmid, Martin G.
    Tesarova, Eva
    ANALYTICA CHIMICA ACTA, 2016, 932 : 98 - 105