Experimental Testing and Validation of a Magnetorheological (MR) Damper Model

被引:11
|
作者
Chooi, Weng Wai [1 ]
Oyadiji, S. Olutunde [1 ]
机构
[1] Univ Manchester, Dynam & Aeroelast Res Grp, Sch Mech Aerosp & Civil Engn, Manchester M60 1QD, Lancs, England
关键词
automotive components; magnetorheology; shock absorbers; SHOCK-ABSORBERS; SUSPENSION;
D O I
10.1115/1.3142885
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The focus of this paper is on the experimental validation of a mathematical model that was developed for the flow of magnetorheological (MR) fluids through the annular gap in a MR damper. Unlike previous work by other researchers, which approximate the flow of the MR fluid through this annulus as a flow of fluid through two infinitely wide parallel plates, the model presented represents accurately the annular flow. In this paper, the mathematical model is validated via experimental testing and analysis of a double-tube MR damper fabricated at the University of Manchester, UK. The experimental setup and the procedures for executing the tests on the MR damper according to established standards for the testing of conventional automotive dampers are given. This involved sets of many isofrequency sinusoidal tests of various displacement amplitudes. Predictions from theoretical simulations based on the mathematical model are validated using the data collected from the experiments. It was found that the modeling procedure represents the MR damper very satisfactorily.
引用
收藏
页码:0610031 / 06100310
页数:10
相关论文
共 50 条
  • [31] LuGre friction model for a magnetorheological damper
    Jiménez, R
    Alvarez-Icaza, L
    STRUCTURAL CONTROL & HEALTH MONITORING, 2005, 12 (01): : 91 - 116
  • [32] Exact physical model of magnetorheological damper
    Graczykowski, Cezary
    Pawlowski, Piotr
    APPLIED MATHEMATICAL MODELLING, 2017, 47 : 400 - 424
  • [33] Research on the Dynamic Model with Magnetorheological Damper
    Niu, Maogui
    Jiang, Hongkai
    PROCEEDINGS OF THE FIRST SYMPOSIUM ON AVIATION MAINTENANCE AND MANAGEMENT, VOL I, 2014, 296 : 323 - 330
  • [34] AN EXPERIMENTAL ELECTROMAGNETIC INDUCTION DEVICE FOR A MAGNETORHEOLOGICAL DAMPER
    Sapinski, Bogdan
    JOURNAL OF THEORETICAL AND APPLIED MECHANICS, 2008, 46 (04) : 933 - 947
  • [35] Hysteresis parameters model of magnetorheological damper
    Wang, Xiuyong, 1600, Chinese Society of Civil Engineering (47):
  • [36] Experimental Study on Performance Characteristics of Magnetorheological Damper
    Hou, Zhenning
    Feng, Zhimin
    Hu, Haigang
    Wu, Guangbin
    ADVANCES IN ENGINEERING DESIGN AND OPTIMIZATION, PTS 1 AND 2, 2011, 37-38 : 439 - 443
  • [37] Real-time model updating for magnetorheological damper identification: an experimental study
    Song, Wei
    Hayati, Saeid
    Zhou, Shanglian
    SMART STRUCTURES AND SYSTEMS, 2017, 20 (05) : 619 - 636
  • [38] Design, Testing and Control of a Magnetorheological Damper for Knee Prostheses
    Song, Hounan
    Cao, Yu
    Chen, Wei
    Ren, Lei
    Ma, Yongxin
    Wang, Kunyang
    Wang, Xu
    Zhang, Yao
    Ren, Luquan
    JOURNAL OF BIONIC ENGINEERING, 2024, 21 (04) : 1788 - 1800
  • [39] Design and Testing of a Novel Vane Type Magnetorheological Damper
    Rakhio, Allah
    Dong, Xiaomin
    Liu, Weiqi
    RECENT ADVANCES IN INTELLIGENT MANUFACTURING, PT I, 2018, 923 : 257 - 266
  • [40] Analysis and testing of a model-scale Magnetorheological fluid helicopter lag mode damper
    Kamath, GM
    Wereley, NM
    Jolly, MR