A sandwich-type electrochemical immunosensor based on the biotin-streptavidin-biotin structure for detection of human immunoglobulin G

被引:17
|
作者
Li, Yueyun [1 ,2 ]
Zhang, Yihe [1 ]
Jiang, Liping [2 ]
Chu, Paul K. [3 ]
Dong, Yunhui [2 ]
Wei, Qin [4 ]
机构
[1] China Univ Geosci, Sch Mat Sci & Technol, Natl Lab Mineral Mat, Beijing Key Lab Mat Utilizat Nonmetall Minerals &, Beijing 100083, Peoples R China
[2] Shandong Univ Technol, Sch Chem Engn, Zibo 255049, Peoples R China
[3] City Univ Hong Kong, Dept Phys & Mat Sci, Tat Chee Ave, Kowloon, Hong Kong, Peoples R China
[4] Univ Jinan, Sch Chem & Chem Engn, Key Lab Chem Sensing & Anal Univ Shandong, Jinan 250022, Peoples R China
来源
SCIENTIFIC REPORTS | 2016年 / 6卷
基金
中国国家自然科学基金;
关键词
SNO2/GRAPHENE NANOCOMPOSITES; CARCINOEMBRYONIC ANTIGEN; FREE IMMUNOASSAY; NANOPARTICLES; GRAPHENE; COMPOSITE; OXIDE; ASSAY; AU;
D O I
10.1038/srep22694
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
A sandwich-type immunosensor is designed and fabricated to detect the human immunoglobulin G (HIgG) using polyaniline and tin dioxide functionalized graphene (GS-SnO2-PAN) as the platform and biotin-functionalized amination magnetic nanoparticles composite (B-Fe3O4@APTES) as the label. GS-SnO2-PAN is used as the sensing agent to capture the primary anti-HIgG (Ab(1)) and SnO2 reduces the stack of GS. The B-Fe3O4@APTES with a large surface area and excellent biocompatibility captures second antibody (Ab(2)) efficiently based on the highly selective recognition of streptavidin to biotinylated antibody. The B-Fe3O4@APTES has better electro-catalytic activity in the reduction of hydrogen peroxide (H2O2) and the "biotin-streptavidin-biotin" (B-SA-B) strategy leads to signal amplification. Under optimal conditions, the immunosensor has a wide sensitivity range from 1 pg/L to 10 ng/L and low detection limit of 0.33 pg/L (S/N = 3) for HIgG. The immunosensor has high sensitivity, fast assay rate, as well as good reproducibility, specificity, and stability especially in the quantitative detection of biomolecules in serum samples.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Sandwich-type ELISA impedimetric immunosensor for early detection of prostate-specific antigen (PSA) in human serum
    Guadalupe Gutierrez-Zuniga, Gabriela
    Luis Hernandez-Lopez, Jose
    NEW PROCESSES AND MATERIALS BASED ON ELECTROCHEMICAL CONCEPTS AT THE MICROSCOPIC LEVEL SYMPOSIUM, MICROECHEM 2013, 2014, 12 : 47 - 54
  • [42] Electrochemical Microfluidic Paper-Based Aptasensor Platform Based on a Biotin-Streptavidin System for Label-Free Detection of Biomarkers
    Ming, Tao
    Cheng, Yan
    Xing, Yu
    Luo, Jinping
    Mao, Gang
    Liu, Juntao
    Sun, Shuai
    Kong, Fanli
    Jin, Hongyan
    Cai, Xinxia
    ACS APPLIED MATERIALS & INTERFACES, 2021, 13 (39) : 46317 - 46324
  • [43] Disposable Sandwich-type Electrochemical Sensor for Selective Detection of Glucose Based on Boronate Affinity
    Li, Jian
    Bai, Zhanming
    Mao, Yanjun
    Sun, Qingqing
    Ning, Xiaohui
    Zheng, Jianbin
    ELECTROANALYSIS, 2017, 29 (10) : 2307 - 2315
  • [44] A Novel Sandwich-Type Electrochemical Immunosensor Based on the Signal Amplification Strategy of Core-shell Pd@Pt Nanoparticles for α-fetoprotein Detection
    Zhang, Ke
    Cao, Zhiwen
    Wang, Shaozhen
    Chen, Jiexia
    Wei, Yan
    Feng, Dexiang
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (03): : 2604 - 2613
  • [45] SERS-based cascade amplification bioassay protocol of miRNA-21 by using sandwich structure with biotin-streptavidin system
    Liang, Zhaoheng
    Zhou, Jun
    Petti, Lucia
    Shao, Liyang
    Jiang, Tao
    Qing, Yanping
    Xie, Shusen
    Wu, Guanyi
    Mormile, Pasquale
    ANALYST, 2019, 144 (05) : 1741 - 1750
  • [46] Triple signal-enhancing sandwich-type electrochemical immunosensor based on Au@SNHC and PtPdCu/BNC for detection of Cardiac Troponin I
    Zhang, Xuelin
    Shang, Qing
    Jiang, Feng
    Dong, Hui
    Li, Yueyuan
    Wang, Shujun
    Tang, Feng
    Liu, Qing
    Li, Yueyun
    Wei, Qin
    BIOELECTROCHEMISTRY, 2023, 154
  • [47] A sandwich-type electrochemical immunosensor based on Au@Pd nanodendrite functionalized MoO2 nanosheet for highly sensitive detection of HBsAg
    Yang, Qingshan
    Wang, Ping
    Ma, Enhui
    Yu, Haoxuan
    Zhou, Kaiwei
    Tang, Chunyuan
    Ren, Jie
    Li, Yueyun
    Liu, Qing
    Dong, Yunhui
    BIOELECTROCHEMISTRY, 2021, 138
  • [48] Detection of biotin-binding immunoglobulin G in human sera using avidin-coated multiwell microplates
    Muratsugu, M
    Kumasaka, K
    Tanaka, M
    Okushima, K
    Fukui, T
    JOURNAL OF HEALTH SCIENCE, 2001, 47 (04) : 424 - 428
  • [49] Electrochemical DNA biosensor based on avidin-biotin conjugation for influenza virus (type A) detection
    Chung, Da-Jung
    Kim, Ki-Chul
    Choi, Seong-Ho
    APPLIED SURFACE SCIENCE, 2011, 257 (22) : 9390 - 9396
  • [50] A sandwich-type immunosensor using Pd-Pt nanocrystals as labels for sensitive detection of human tissue polypeptide antigen
    Wang, Yaoguang
    Wei, Qin
    Zhang, Yong
    Wu, Dan
    Ma, Hongmin
    Guo, Aiping
    Du, Bin
    NANOTECHNOLOGY, 2014, 25 (05)