Lateral-torsional buckling behaviour of concrete-filled high-strength steel tubular flange beams under mid-span load

被引:14
|
作者
Gao, Fei [1 ,2 ]
Yang, Fan [1 ,2 ]
Zhu, Hongping [1 ,2 ]
Liang, Hongjun [3 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Civil Engn & Mech, Wuhan 430074, Hubei, Peoples R China
[2] Huazhong Univ Sci & Technol, Hubei Key Lab Control Struct, Wuhan 430074, Hubei, Peoples R China
[3] Wuhan Univ, Sch Civil Engn, Wuhan 430072, Peoples R China
基金
中国国家自然科学基金;
关键词
Tubular flange beam; High-strength steel; Flexural strength; Lateral-torsional buckling; PLATE GIRDERS; FLEXURAL BEHAVIOR; RESIDUAL-STRESSES; I-GIRDER; CAPACITY; COLUMNS; DESIGN; SQUARE; TESTS;
D O I
10.1016/j.jcsr.2020.106398
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Lateral-torsional buckling (LTB) behaviour of concrete-filled high-strength steel tubular flange beams (HS-CFTFBs) is experimentally and numerically investigated. Six specimens are tested in simple support with a lateral unrestrained concentrated load in mid-span. Among them, two are failure controlled through flexural yielding (FY), whereas the remaining specimens are controlled through LTB. Finite-element (FE) models are then constructed and the comparison with the experimental results indicates that they could reliably and accurately evaluate failure modes, load-displacement relationship and ultimate capacities of HS-CFTFBs. These verified FE models are consequently used to investigate the effect of flange depth, concrete and steel with various span lengths. Results suggest that the ultimate moment capacity evidently decreases as the span length increased, particularly for the high-strength steel beams. The increasing flange depth remarkably improved the LTB strength but merely slightly increased the amount of steel. The infilled concrete could improve the resistance to flange distortion and thus increase the ultimate capacity. However, the strength of concrete exhibits a slight influence on ultimate capacity. Increasing fy could improve the LTB capacity when the span length is relatively small, but the improvements decrease with increasing span length. When the failure mode is elastic LTB, increased fy could substantially improve post-buckling stiffness and ductility (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Behaviours of circular high-strength concrete-filled high-strength steel tubular columns after constant heating
    Du, Tao
    Liu, Faqi
    Wei, Huiyu
    Li, Ying
    Yang, Hua
    Peng, Kang
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2024, 221
  • [32] Flexural behaviour of high-strength rectangular concrete-filled steel hollow sections
    Gho, WM
    Liu, DL
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2004, 60 (11) : 1681 - 1696
  • [33] Experimental investigations of concrete-filled steel tubular columns confined with high-strength steel wire
    Wei, Yang
    Cheng, Xunyu
    Wu, Gang
    Duan, Maojun
    Wang, Libin
    ADVANCES IN STRUCTURAL ENGINEERING, 2019, 22 (13) : 2771 - 2784
  • [34] Lateral-torsional buckling resistance of cold-formed high strength steel rectangular hollow beams
    Tran, Anh Tuan
    INSIGHTS AND INNOVATIONS IN STRUCTURAL ENGINEERING, MECHANICS AND COMPUTATION, 2016, : 1051 - 1055
  • [35] Behaviour of high-strength spirally reinforced square concrete-filled steel tubes under eccentric compression
    Li, Wei-Jie
    Li, Wei
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2025, 228
  • [36] Experimental study on behavior of circular concrete-filled high-strength steel tubular stub columns under compression
    Wang Y.
    Song C.
    Zhao X.
    Li G.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2022, 43 (11): : 221 - 234
  • [37] Behavior of CFRP confined rectangular high-strength concrete-filled steel tubular columns under eccentric compression
    Gao, Dinghui
    Du, Yansheng
    Chen, Zhihua
    Zhao, Bingzhen
    ENGINEERING STRUCTURES, 2024, 321
  • [38] Basic behavior of high-strength concrete-filled steel tubular short columns under axial compressive loading
    Wang, Yu-Yin
    Zhang, Su-Mei
    Yang, Hua
    Advances in Structural Engineering:Theory and Applications Vols 1 and 2, 2006, : 1436 - 1442
  • [39] Cyclic lateral load test and finite element analysis of high-strength concrete-filled steel box columns under high axial compression
    Chou, Chung-Che
    Wu, Sung-Cheng
    ENGINEERING STRUCTURES, 2019, 189 : 89 - 99
  • [40] Compressive behavior of concrete-filled steel tubular columns with internal high-strength steel spiral confinement
    Teng, J. G.
    Wang, J. J.
    Lin, Guan
    Zhang, J.
    Feng, P.
    ADVANCES IN STRUCTURAL ENGINEERING, 2021, 24 (08) : 1687 - 1708