Development and validation of a method for gefitinib quantification in dried blood spots using liquid chromatography-tandem mass spectrometry: Application to finger-prick clinical blood samples of patients with non-small cell lung cancer

被引:18
|
作者
Irie, Kei [1 ,2 ]
Shobu, Saori [2 ]
Hiratsuji, Seika [2 ]
Yamasaki, Yuta [2 ]
Nanjo, Shigeki [3 ]
Kokan, Chiyuki [3 ]
Hata, Akito [3 ]
Kaji, Reiko [3 ]
Masago, Katsuhiro [3 ]
Fujita, Shiro [3 ]
Okada, Yutaka [1 ]
Katakami, Nobuyuki [3 ]
Fukushima, Shoji [2 ]
机构
[1] Inst Biomed Res & Innovat Hosp, Div Pharm, Chuo Ku, 2-2-1 Minatojima Minami Machi, Kobe, Hyogo 6500047, Japan
[2] Kobe Gakuin Univ, Fac Pharmaceut Sci, Dept Pharmaceut, Chuo Ku, 1-1-3 Minatojima, Kobe, Hyogo 6508586, Japan
[3] Inst Biomed Res & Innovat Hosp, Div Integrated Oncol, Chuo Ku, 2-2-1 Minatojima Minami Machi, Kobe, Hyogo 6500047, Japan
关键词
QUANTITATIVE BIOANALYSIS; ASSAY BIAS; HEMATOCRIT; ERLOTINIB; PLASMA; ZD1839;
D O I
10.1016/j.jchromb.2018.04.027
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantification of gefitinib in dried blood spots (DBSs). Gefitinib was extracted with methanol from DBS of 3 mm in diameter and detected using a triple quadrupole mass spectrometer. The method was validated by evaluating its precision, accuracy, selectivity, carryover, matrix effect, recovery, and stability. For clinical validation, paired finger-prick DBS and plasma concentrations were compared for 10 patients with non-small cell lung cancer (NSCLC) taking gefitinib. The calibration linear range was 37.5-2400 ng/mL (coefficient of determination [R-2] = 0.99), encompassing the therapeutic concentrations of gefitinib. The accuracy and precision were within 15% of the quality control (QC) concentrations of 80, 200, and 2000 ng/mL. The lower limit of quantification was determined to be 40 ng/mL. Gefitinib was stable in DBSs for up to 5 months at room temperature and - 20 degrees C, and at 40 degrees C for 24 h. A good correlation was observed between the gefitinib levels measured by the DBS method and plasma concentrations (R-2 = 0.99). This method provides a simple, fast, and accurate approach to the quantitative analysis of gefitinib in finger-prick DBSs. The method would be useful for minimally invasive evaluation of the clinical gefitinib blood concentration.
引用
收藏
页码:1 / 5
页数:5
相关论文
共 50 条
  • [21] Rapid steroid hormone quantification for congenital adrenal hyperplasia (CAH) in dried blood spots using UPLC liquid chromatography-tandem mass spectrometry
    Janzen, Nils
    Sander, Stefanie
    Terhardt, Michael
    Steuerwald, Ulrike
    Peter, Michael
    Das, Anibh M.
    Sander, Johannes
    STEROIDS, 2011, 76 (13) : 1437 - 1442
  • [22] Comparison of the quantification of acetaminophen in plasma, cerebrospinal fluid and dried blood spots using high-performance liquid chromatography-tandem mass spectrometry
    Taylor, Rachel R.
    Hoffman, Keith L.
    Schniedewind, Bjoern
    Clavijo, Claudia
    Galinkin, Jeffrey L.
    Christians, Uwe
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2013, 83 : 1 - 9
  • [23] Analysis of six different homologues of phosphatidylethanol from dried blood spots using liquid chromatography-tandem mass spectrometry
    Aboutara, Nadine
    Jungen, Hilke
    Szewczyk, Anne
    Sterneck, Martina
    Mueller, Alexander
    Iwersen-Bergmann, Stefanie
    DRUG TESTING AND ANALYSIS, 2021, 13 (01) : 140 - 147
  • [24] A simplified method for bortezomib determination using dried blood spots in combination with liquid chromatography/tandem mass spectrometry
    Guo, Zi-Xuan
    Yang, Fan
    van den Anker, Johannes N.
    Zheng, Yi
    Zhao, Wei
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2021, 1181
  • [25] Volumetric dried blood spots for determination of phosphatidylethanol: Validation of a liquid chromatography tandem masspectrometry method and clinical application
    Beck, Olof
    Barroso, Miguel
    Hermansson, Sigurd
    Widen, Cristopher
    Wallin, Christer
    Nilsson-Wallmark, Cecilia
    de Bejczy, Andrea
    DRUG TESTING AND ANALYSIS, 2025, 17 (02) : 231 - 237
  • [26] Evaluating the detection of barbiturates in dried blood spots: A comparative analysis using gas chromatography-mass spectrometry, gas chromatography-tandem mass spectrometry, and liquid chromatography-tandem mass spectrometry with different extraction methods
    Zhi, Yujie
    Lu, Jiayue
    Zheng, Qiongying
    Cao, Xinyu
    Lv, Min
    Xu, Qing
    Xiang, Ping
    Liu, Wei
    Di, Bin
    Fan, Xianyu
    Chen, Hang
    JOURNAL OF CHROMATOGRAPHY A, 2024, 1737
  • [27] Quantification of sulfatides in dried blood and urine spots from metachromatic leukodystrophy patients by liquid chromatography/electrospray tandem mass spectrometry
    Barcenas, Mariana
    Suhr, Teryn R.
    Scott, C. Ronald
    Turecek, Frantisek
    Gelb, Michael H.
    CLINICA CHIMICA ACTA, 2014, 433 : 39 - 43
  • [28] Quantitative analysis of clofazimine (Lamprene®), an antileprosy agent, in human dried blood spots using liquid chromatography-tandem mass spectrometry
    Li, Wenkui
    Doherty, John
    Fu, Yunlin
    Flarakos, Jimmy
    BIOMEDICAL CHROMATOGRAPHY, 2018, 32 (02)
  • [29] Simultaneous determination of fluoxetine and norfluoxetine in dried blood spots using high-performance liquid chromatography-tandem mass spectrometry
    Cezimbra da Silva, Anne Caroline
    Raasch, Juliana Raquel
    Vargas, Tainara Gomes
    Peteffi, Giovana Piva
    Hahn, Roberta Zilles
    Antunes, Marina Venzon
    Perassolo, Magda Susana
    Linden, Rafael
    CLINICAL BIOCHEMISTRY, 2018, 52 : 85 - 93
  • [30] Quantitative Analysis of Porphyrins in Dried Blood Spots Using Liquid Chromatography-tandem Mass Spectrometry with Pre-column Derivatization
    Hur, Yeoun
    Han, Sang Beom
    Kang, Seung Woo
    Lee, Youngshin
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2014, 35 (10) : 3103 - 3106