Treatment of renal artery in-stent restenosis with sirolimus-eluting stents

被引:9
|
作者
Kiernan, Thomas J. [1 ]
Yan, Bryan P. [1 ]
Eisenberg, Jonathan D. [1 ]
Ruggiero, Nicholas J. [1 ]
Gupta, Vishal [1 ]
Drachman, Douglas [1 ]
Schainfeld, Robert M. [1 ]
Jaff, Michael R. [1 ]
Rosenfield, Kenneth [1 ]
Garasic, Joseph [1 ]
机构
[1] Massachusetts Gen Hosp, Dept Intervent Cardiol & Vasc Med, Boston, MA 02114 USA
关键词
hypertension; in-stent restenosis; renal artery stenosis; sirolimus; BALLOON ANGIOPLASTY; STENOSIS; PLACEMENT; DISEASE;
D O I
10.1177/1358863X09106897
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
The objective of this study was to analyze the use of sirolimus-eluting stent (SES) placement for the treatment of renal artery in-stent restenosis (RA-ISR). The optimal treatment of RA-ISR has not been fully elucidated to date. We retrospectively analyzed consecutive patients from our institution who underwent treatment of RA-ISR with a SES from May 2004 to June 2006. Using duplex ultrasound, RA-ISR (> 60% diameter) was determined by peak systolic velocity (PSV) > 300 cm/s and renal aortic ratio (RAR) > 4.0. Renal function (creatinine) and blood pressure were measured at baseline and follow-up. SESs were implanted in 16 patients (22 renal arteries) during the study period. The study cohort was predominantly female (75%) with a mean age of 68 +/- 12 years. RA-ISR was treated with SESs with a mean diameter of 3.5 mm and mean length of 17.9 +/- 3.8 mm. The mean post-dilation balloon diameter was 4.8 +/- 0.6. The baseline renal artery PSV was 445 +/- 131 cm/s with a mean RAR of 5.0 +/- 1.6. Follow-up information was available in 21 renal arteries. During a median follow-up of 12 months (range: 9-15 months), 15 renal arteries (71.4%) developed recurrence of ISR by ultrasonographic criteria. Univariate analysis revealed that female sex was an independent predictor of recurrence of ISR after SES implantation (p < 0.05). In conclusion, placement of a SES for the treatment of ISR in renal arteries is associated with high initial technical success but significant restenosis on duplex ultrasonography at follow-up.
引用
收藏
页码:3 / 7
页数:5
相关论文
共 50 条
  • [41] Clinical outcomes for Sirolimus-Eluting stent implantation and vascular brachytherapy for the treatment of in-stent restenosis
    Saia, F
    Lemos, PA
    Hoye, A
    Sianos, G
    Arampatzis, CA
    de Feyter, PJ
    van der Giessen, WJ
    Smits, PC
    van Domburg, RT
    Serruys, PW
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2004, 62 (03) : 283 - 288
  • [42] CYPHER™ sirolimus-eluting Bx velocity stent is safe and effective for the treatment of in-stent restenosis
    Alameddine, FF
    Costa, M
    Katz, S
    Perin, E
    Cohen, S
    Ramee, S
    Berger, P
    Block, PC
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (03) : 44A - 44A
  • [43] Effectiveness of sirolimus-eluting stent implantation for treatment of in-stent restenosis after brachytherapy failure
    Iakovou, L
    Sangiorgi, GM
    Stankovic, G
    Corvaja, N
    Michev, I
    Chieffo, A
    Rogacka, R
    Vitrella, G
    Airoldi, F
    Colombo, A
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2004, 94 (03): : 351 - 354
  • [44] Treatment of in-stent restenosis with sirolimus-eluting stent:: Long-term clinical outcome
    Sheiban, Imad
    Chiribiri, Amedeo
    Beninati, Serena
    Moretti, Claudio
    Omede, Pierluigi
    Sciuto, Filippo
    Meliga, Emauele
    Grossomarra, Walter
    Trevi, Giampaolo
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2006, 98 (8A): : 154M - 155M
  • [45] Safety and efficacy of repeat sirolimus-eluting stent implantation for in-stent restenosis of drug-eluting stents: Comparison with conventional treatment.
    Kim, YH
    Park, SW
    Lee, BK
    Park, DW
    Hwang, ES
    Jeong, YH
    Lee, SW
    Lee, CW
    Hong, MK
    Kim, JJ
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2006, 97 (8B): : 45D - 45D
  • [46] Sirolimus-Eluting Stents or Vascular Brachytherapy for In-Stent Restenosis After 3-Year Follow-Up of the SISR (Sirolimus-Eluting Stent Versus Vascular Brachytherapy for In-Stent Restenosis) Trial A Call for Caution?
    Rodriguez, Alfredo E.
    Waksman, Ron
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (01) : 75 - 76
  • [47] Sirolimus-eluting stent placement for refractory renal artery in-stent restenosis: sustained patency and clinical benefit at 24 months
    Lookstein, Robert A.
    Talenfeld, Adam D.
    Raju, Roman
    Vorchheimer, David A.
    Olin, Jeffrey W.
    Marin, Michael L.
    [J]. VASCULAR MEDICINE, 2009, 14 (04) : 361 - 364
  • [48] Sirolimus-eluting stents vs. intracoronary brachytherapy for the treatment of in-stent restenosis: A serial intravascular ultrasound analysis
    Kaneda, H
    Ako, J
    Kataoka, T
    Takahashi, T
    Terashima, M
    Shimada, Y
    Waseda, K
    Miyazawa, A
    Sakurai, R
    Honda, Y
    Yock, PG
    Fitzgerald, PJ
    [J]. CIRCULATION, 2005, 112 (17) : U834 - U834
  • [49] Comparison between sirolimus-eluting stents and intracoronary catheter-based beta radiation for the treatment of in-stent restenosis
    Feres, F
    Muñoz, JS
    Abizaid, A
    Albertal, M
    Mintz, GS
    Staico, R
    Centemero, M
    Mattos, LA
    Maldonado, G
    Tanajura, LF
    Chaves, A
    Pinto, I
    Abizaid, AS
    Seixas, AC
    Vaz, VD
    Sousa, A
    Sousa, JE
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2005, 96 (12): : 1656 - 1662
  • [50] A case of late thrombosis following treatment of in-stent restenosis with sirolimus-eluting stents due to discontinuation of antiplatelet agents
    Arslan, Ugur
    Turkoglu, Sedat
    Timurkaynak, Timur
    [J]. TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2007, 35 (01): : 43 - 47