Treatment of renal artery in-stent restenosis with sirolimus-eluting stents

被引:9
|
作者
Kiernan, Thomas J. [1 ]
Yan, Bryan P. [1 ]
Eisenberg, Jonathan D. [1 ]
Ruggiero, Nicholas J. [1 ]
Gupta, Vishal [1 ]
Drachman, Douglas [1 ]
Schainfeld, Robert M. [1 ]
Jaff, Michael R. [1 ]
Rosenfield, Kenneth [1 ]
Garasic, Joseph [1 ]
机构
[1] Massachusetts Gen Hosp, Dept Intervent Cardiol & Vasc Med, Boston, MA 02114 USA
关键词
hypertension; in-stent restenosis; renal artery stenosis; sirolimus; BALLOON ANGIOPLASTY; STENOSIS; PLACEMENT; DISEASE;
D O I
10.1177/1358863X09106897
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
The objective of this study was to analyze the use of sirolimus-eluting stent (SES) placement for the treatment of renal artery in-stent restenosis (RA-ISR). The optimal treatment of RA-ISR has not been fully elucidated to date. We retrospectively analyzed consecutive patients from our institution who underwent treatment of RA-ISR with a SES from May 2004 to June 2006. Using duplex ultrasound, RA-ISR (> 60% diameter) was determined by peak systolic velocity (PSV) > 300 cm/s and renal aortic ratio (RAR) > 4.0. Renal function (creatinine) and blood pressure were measured at baseline and follow-up. SESs were implanted in 16 patients (22 renal arteries) during the study period. The study cohort was predominantly female (75%) with a mean age of 68 +/- 12 years. RA-ISR was treated with SESs with a mean diameter of 3.5 mm and mean length of 17.9 +/- 3.8 mm. The mean post-dilation balloon diameter was 4.8 +/- 0.6. The baseline renal artery PSV was 445 +/- 131 cm/s with a mean RAR of 5.0 +/- 1.6. Follow-up information was available in 21 renal arteries. During a median follow-up of 12 months (range: 9-15 months), 15 renal arteries (71.4%) developed recurrence of ISR by ultrasonographic criteria. Univariate analysis revealed that female sex was an independent predictor of recurrence of ISR after SES implantation (p < 0.05). In conclusion, placement of a SES for the treatment of ISR in renal arteries is associated with high initial technical success but significant restenosis on duplex ultrasonography at follow-up.
引用
收藏
页码:3 / 7
页数:5
相关论文
共 50 条
  • [1] Treatment of coronary in-stent restenosis with sirolimus-eluting stents
    Urban, P
    Guagliumi, G
    Gershlick, A
    Lotan, C
    Sousa, E
    Wijns, W
    Seth, A
    [J]. EUROPEAN HEART JOURNAL, 2004, 25 : 671 - 671
  • [2] Late Restenosis of Sirolimus-eluting Stent in the Treatment of In-stent Restenosis of Sirolimus-eluting Stent
    Shibayama, Kentaro
    Kadota, Kazushige
    Tsujimoto, Yuki
    Saito, Naoki
    Miyamoto, Masakazu
    Otsuru, Suguru
    Okamoto, Yoji
    Imai, Masao
    Tasaka, Hiroshi
    Hasegawa, Daiji
    Shigemoto, Yoshikazu
    Habara, Seiji
    Tanaka, Hiroyuki
    Maruo, Takeshi
    Hirono, Akitoshi
    Nishibori, Yosiharu
    Hosogi, Shingo
    Fuku, Yasushi
    Oka, Naoki
    Katoh, Hurumi
    Yamamoto, Hiroyuki
    Fujii, Satoki
    Goto, Tsuyoshi
    Inoue, Katsumi
    Mitsudo, Kazuaki
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (6A): : 161D - 161D
  • [3] Sirolimus-Eluting Stents: Safe and effective in the treatment of in-stent restenosis
    Neumann, FJ
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2005, 66 (02) : 163 - 164
  • [4] Sirolimus-eluting stent for treatment of in-stent restenosis
    Le Feuvre, C
    Montalescot, G
    Rosey, G
    Monsegu, J
    Ohanessian, A
    Spaulding, C
    Drobinski, G
    Metzger, JP
    [J]. EUROPEAN HEART JOURNAL, 2004, 25 : 316 - 316
  • [5] Sirolimus-eluting stents for treatment of in-stent restenosis -: Immediate and late results
    Medina, A
    de Lezo, JS
    Pan, M
    Delgado, A
    Segura, J
    Pavlovic, D
    Melián, F
    Romero, M
    Segura, F
    Hernández, E
    Ureña, I
    Herrador, J
    [J]. TEXAS HEART INSTITUTE JOURNAL, 2005, 32 (01): : 11 - 15
  • [6] Real world use of sirolimus-eluting stents for the treatment of in-stent restenosis
    Sousa, JE
    Sousa, A
    Abizaid, A
    Seabra-Gomes, R
    Moreira, A
    Cano, M
    Urban, P
    Lotan, C
    Gershlick, A
    Seth, A
    Deme, M
    [J]. CIRCULATION, 2004, 110 (17) : 756 - 756
  • [7] Immediate and midterm results of the treatment of in-stent restenosis with sirolimus-eluting stents
    Rogacka, R
    Airoldi, F
    Montorfano, M
    Carlino, M
    Chieffo, A
    Michev, I
    Mikhail, G
    Colombo, A
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2003, 92 (6A): : 89L - 89L
  • [8] Everolimus versus sirolimus-eluting stents for the treatment of sirolimus-eluting stent restenosis
    Yan, Rong-Qiang
    Gao, Li-Jian
    Chen, Ji-Lin
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 165 (03) : 568 - 569
  • [9] Treatment of in-stent restenosis using sirolimus-eluting stents: ISR II registry
    Commeau, P
    Barragan, PT
    Roquebert, PO
    Bouvier, JL
    Comet, B
    Macaluso, G
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (06) : 53A - 53A
  • [10] Significant association of coronary stent fracture with in-stent restenosis in sirolimus-eluting stents
    Kim, Jung-Sun
    Lee, Seung-Yul
    Lee, Jung Myung
    Yoon, Young Won
    Ahn, Chul-Min
    Kim, Myung-Hyun
    Min, Pil-Ki
    Ko, Young-Guk
    Hong, Bum-Kee
    Choi, Donghoon
    Kwon, Hyuck Moon
    Jang, Yangsoo
    Shim, Won-Heum
    [J]. CORONARY ARTERY DISEASE, 2009, 20 (01) : 59 - 63