Agreement of infrared temporal artery thermometry with other thermometry methods in adults: systematic review

被引:13
|
作者
Kiekkas, Panagiotis [1 ]
Stefanopoulos, Nikolaos [1 ]
Bakalis, Nick [1 ]
Kefaliakos, Antonios [1 ]
Karanikolas, Menelaos [2 ]
机构
[1] Technol Educ Inst Western Greece, Dept Nursing, Patras, Greece
[2] Washington Univ, Sch Med, Dept Anesthesiol, St Louis, MO 63110 USA
关键词
accuracy; adult patients; precision; temperature measurement; temporal artery; thermometry; NONINVASIVE TEMPERATURE-MEASUREMENT; BLADDER THERMOMETRY; CORE; ACCURACY; HYPOTHERMIA; SURGERY;
D O I
10.1111/jocn.13117
中图分类号
R47 [护理学];
学科分类号
1011 ;
摘要
Aims and objectivesTo critically review and synthesise the evidence on the agreement of temporal artery thermometry with invasive and noninvasive thermometry methods in hospitalised adults. BackgroundNoninvasive thermometry methods aim at combining patient comfort and ease of use with satisfactory accuracy of temperature measurements. Infrared temporal artery thermometry is based on the detection of heat radiated from this artery in the forehead and temporal region. DesignSystematic literature review. MethodsA literature search was conducted in Pubmed, CINAHL, Cochrane Library, Web of Science and Embase. Data were extracted from twenty method-comparison studies published between 2002-2015. Methodological quality of selected studies was evaluated. ResultsTemperature measurements of temporal artery were compared with pulmonary artery, urinary bladder, oesophageal or nasopharyngeal ones in eight studies for the whole temperature range. Accuracy and precision of temporal artery thermometry exceeded recommended levels of 03 degrees C in three and six studies respectively. Likewise, in nine studies that compared temporal artery temperature measurements with oral and ear-based ones, satisfactory agreement and variability was reported in five and none of them respectively. With regard to fever and hypothermia, although specificity of temporal artery thermometers for detecting these disorders was satisfactory, their sensitivity was low. ConclusionsExisting evidence does not support that temporal artery thermometry can replace common invasive and noninvasive thermometry methods in adult patients. Relevance to clinical practiceHealth care professionals are recommended to avoid the use of infrared temporal artery temporal artery thermometry in adults, or be cautious about the accuracy and precision of its readings, until improved devices are developed.
引用
收藏
页码:894 / 905
页数:12
相关论文
共 50 条
  • [21] Comparison of the temporal artery and rectal thermometry in children in the emergency department
    Schuh, S
    Komar, L
    Stephens, D
    Chu, L
    Read, S
    Allen, U
    PEDIATRIC RESEARCH, 2003, 53 (04) : 112A - 112A
  • [23] An initial study on the agreement of body temperatures measured by infrared cameras and oral thermometry
    Adams, Scott
    Bucknall, Tracey
    Kouzani, Abbas
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [24] An initial study on the agreement of body temperatures measured by infrared cameras and oral thermometry
    Scott Adams
    Tracey Bucknall
    Abbas Kouzani
    Scientific Reports, 11
  • [25] Agreement of zero-heat-flux thermometry compared with infrared tympanic temperature monitoring in adults undergoing major surgery
    Wang, Jingyan
    Liang, Hao
    Tian, Congzhe
    Rong, Guiyuan
    Shao, Xinfeng
    Ran, Cheng
    EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2025, 30 (01)
  • [26] Accuracy of Temporal Artery Thermometry in Neonatal Intensive Care Unit Infants
    Rollins, Kristian
    Flannery-Bergey, Diane
    JOGNN-JOURNAL OF OBSTETRIC GYNECOLOGIC AND NEONATAL NURSING, 2011, 40 : S112 - S112
  • [27] Validation of the temporal artery thermometry by its comparison with the esophageal method in children
    Al-Mukazeem, F
    Allen, U
    Komar, L
    Naser, B
    Roy, L
    Stephens, D
    Read, S
    Kim, C
    Schuh, S
    PEDIATRIC RESEARCH, 2003, 53 (04) : 107A - 107A
  • [28] Accuracy of Infrared Tympanic Thermometry Used in the Diagnosis of Fever in Children: A Systematic Review and Meta-Analysis
    Zhen, Chen
    Xia, Zhang
    Jun, Zhou Ya
    Long, Li
    Jian, Shuai
    Ju, Cai Gui
    Long, Li
    CLINICAL PEDIATRICS, 2015, 54 (02) : 114 - 126
  • [29] PRECISE RESISTANCE THERMOMETRY .I. DC METHODS - A REVIEW
    DANEMAN, HL
    MERGNER, GC
    INSTRUMENTATION TECHNOLOGY, 1967, 14 (05): : 51 - &
  • [30] Non-invasive temporal artery thermometry: Physics, physiology, and clinical accuracy
    Pompei, F
    Pompei, M
    THERMOSENSE XXVI, 2004, 5405 : 61 - 67