Agreement of infrared temporal artery thermometry with other thermometry methods in adults: systematic review

被引:13
|
作者
Kiekkas, Panagiotis [1 ]
Stefanopoulos, Nikolaos [1 ]
Bakalis, Nick [1 ]
Kefaliakos, Antonios [1 ]
Karanikolas, Menelaos [2 ]
机构
[1] Technol Educ Inst Western Greece, Dept Nursing, Patras, Greece
[2] Washington Univ, Sch Med, Dept Anesthesiol, St Louis, MO 63110 USA
关键词
accuracy; adult patients; precision; temperature measurement; temporal artery; thermometry; NONINVASIVE TEMPERATURE-MEASUREMENT; BLADDER THERMOMETRY; CORE; ACCURACY; HYPOTHERMIA; SURGERY;
D O I
10.1111/jocn.13117
中图分类号
R47 [护理学];
学科分类号
1011 ;
摘要
Aims and objectivesTo critically review and synthesise the evidence on the agreement of temporal artery thermometry with invasive and noninvasive thermometry methods in hospitalised adults. BackgroundNoninvasive thermometry methods aim at combining patient comfort and ease of use with satisfactory accuracy of temperature measurements. Infrared temporal artery thermometry is based on the detection of heat radiated from this artery in the forehead and temporal region. DesignSystematic literature review. MethodsA literature search was conducted in Pubmed, CINAHL, Cochrane Library, Web of Science and Embase. Data were extracted from twenty method-comparison studies published between 2002-2015. Methodological quality of selected studies was evaluated. ResultsTemperature measurements of temporal artery were compared with pulmonary artery, urinary bladder, oesophageal or nasopharyngeal ones in eight studies for the whole temperature range. Accuracy and precision of temporal artery thermometry exceeded recommended levels of 03 degrees C in three and six studies respectively. Likewise, in nine studies that compared temporal artery temperature measurements with oral and ear-based ones, satisfactory agreement and variability was reported in five and none of them respectively. With regard to fever and hypothermia, although specificity of temporal artery thermometers for detecting these disorders was satisfactory, their sensitivity was low. ConclusionsExisting evidence does not support that temporal artery thermometry can replace common invasive and noninvasive thermometry methods in adult patients. Relevance to clinical practiceHealth care professionals are recommended to avoid the use of infrared temporal artery temporal artery thermometry in adults, or be cautious about the accuracy and precision of its readings, until improved devices are developed.
引用
收藏
页码:894 / 905
页数:12
相关论文
共 50 条
  • [1] Infrared ear thermometry compared with rectal thermometry in children: a systematic review
    Craig, JV
    Lancaster, GA
    Taylor, S
    Williamson, PR
    Smyth, RL
    LANCET, 2002, 360 (9333): : 603 - 609
  • [2] Temporal Artery Thermometry in Pediatric Patients: Systematic Review and Meta-Analysis
    Kiekkas, Panagiotis
    Aretha, Diamanto
    Almpani, Eleni
    Stefanopoulos, Nikolaos
    JOURNAL OF PEDIATRIC NURSING-NURSING CARE OF CHILDREN & FAMILIES, 2019, 46 : 89 - 99
  • [3] Noninvasive Temporal Artery Thermometry as an Alternative to Rectal Thermometry in Research Macaques
    Woods, S. E.
    Marini, R. P.
    Patterson, M. M.
    JOURNAL OF THE AMERICAN ASSOCIATION FOR LABORATORY ANIMAL SCIENCE, 2012, 51 (05): : 640 - 641
  • [4] COMPARISON OF INFRARED FOREHEAD AND TYMPANIC THERMOMETRY WITH GLASS MERCURY THERMOMETRY IN ADULTS
    Khan, Maaz Moin
    Nazar, Madeeha
    Anjum, Nida
    INDO AMERICAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2018, 5 (11): : 12806 - 12809
  • [5] Temporal artery thermometry as accurate as rectal
    不详
    CRITICAL CARE NURSE, 2010, 30 (03) : 10 - 10
  • [6] Acceptance of temporal artery thermometry by Nigerian mothers: a comparison with the traditional methods
    Kelechi, Odinaka
    Benedict, Edelu
    Nwolisa, Emeka
    Ifeyinwa, Amamilo
    Seline, Okolo
    PAN AFRICAN MEDICAL JOURNAL, 2014, 19
  • [7] Comparison of Temporal Artery Thermometry with Axillary and Rectal Thermometry in Full Term Neonates
    Goswami, Ekta
    Batra, Prerna
    Khurana, Ritika
    Dewan, Pooja
    INDIAN JOURNAL OF PEDIATRICS, 2017, 84 (03): : 195 - 199
  • [8] Comparison of Temporal Artery Thermometry with Axillary and Rectal Thermometry in Full Term Neonates
    Ekta Goswami
    Prerna Batra
    Ritika Khurana
    Pooja Dewan
    The Indian Journal of Pediatrics, 2017, 84 : 195 - 199
  • [9] Temporal artery and axillary thermometry comparison with rectal thermometry in children presenting to the ED
    Forrest, Adam J.
    Juliano, Michael L.
    Conley, Sean P.
    Cronyn, Patrick D.
    McGlynn, Andrea
    Auten, Jonathan D.
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2017, 35 (12): : 1855 - 1858
  • [10] Temporal Artery Thermometry in Children Younger Than 5 Years A Comparison With Rectal Thermometry
    Odinaka, Kelechi K.
    Edelu, Benedict O.
    Nwolisa, Charles E.
    Amamilo, Ifeyinwa B.
    Okolo, Seline N.
    PEDIATRIC EMERGENCY CARE, 2014, 30 (12) : 867 - 870