Knee Android Model Reproducing Internal-External Rotation with Screw-Home Movement of Human Knee

被引:0
|
作者
Yamauchi, Daichi [1 ]
Takei, Sho [1 ]
Sato, Noritaka [1 ]
Morita, Yoshifumi [1 ]
机构
[1] Nagoya Inst Technol, Dept Comp Sci & Engn, Showa Ku, Nagoya, Aichi 4668555, Japan
关键词
Android model; Knee model; Human knee joint; Screw-home movement; Joint mechanism;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
This paper proposed a knee android model (Knee-AM) that can reproduce the internal-external rotation with screw-home movement (SHM) of the human knee. This rotation of the Knee-AM was realized by changing the number, the lengths and the fixing points of the nylon-cords of our previous Knee-AM. Moreover, when the anterior cruciate ligament (ACL) was removed from the Knee-AM to imitate ligament injury, the SHM did not occur during knee extension. The results showed the ACL played an important role for the SHM.
引用
收藏
页码:146 / 150
页数:5
相关论文
共 50 条
  • [1] Knee Android Model Reproducing Internal-External Rotation with Screw-Home Movement of the Human Knee
    Yamauchi, Daichi
    Takei, Sho
    Sato, Noritaka
    Morita, Yoshifumi
    JOURNAL OF ROBOTICS NETWORKING AND ARTIFICIAL LIFE, 2016, 3 (02): : 69 - 73
  • [2] SCREW-HOME MOVEMENT IN KNEE-JOINT
    HALLEN, LG
    LINDAHL, O
    ACTA ORTHOPAEDICA SCANDINAVICA, 1966, 37 (01): : 97 - &
  • [3] An Experimental Study on the Relationship between the Components and Movement of the Human Knee Using an Android Model - Measurement of Internal-External Rotation and Anterior-Posterior Tibial Translation
    Yamauchi, Daichi
    Sato, Noritaka
    Morita, Yoshifumi
    2015 15TH INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND SYSTEMS (ICCAS), 2015, : 811 - 815
  • [4] Comparison of screw-home movement between patients with knee osteoarthritis and normal adults
    Jeon, Jeongwoo
    Lhee, Sang Hoon
    Chong, Suri
    Lee, Dongyeop
    Yu, Jaeho
    Kim, Jinseop
    Kim, Seong-Gil
    Hong, Jiheon
    JOURNAL OF BACK AND MUSCULOSKELETAL REHABILITATION, 2022, 35 (06) : 1211 - 1218
  • [5] Location of the natural knee axis for internal-external tibial rotation
    Boguszewski, Daniel V.
    Joshi, Nirav B.
    Yang, Paul R.
    Markolf, Keith L.
    Petrigliano, Frank A.
    McAllister, David R.
    KNEE, 2016, 23 (06): : 1083 - 1088
  • [6] Accurate internal-external rotation measurement in total knee prostheses: A magnetic solution
    Arami, Arash
    Miehlbradt, Jenifer
    Aminian, Kamiar
    JOURNAL OF BIOMECHANICS, 2012, 45 (11) : 2023 - 2027
  • [7] Measurement of the screw-home motion of the knee is sensitive to errors in axis alignment
    Piazza, SJ
    Cavanagh, PR
    JOURNAL OF BIOMECHANICS, 2000, 33 (08) : 1029 - 1034
  • [8] Prophylactic ankle braces and knee varus-valgus and internal-external rotation torque
    Venesky, Kandy
    Docherty, Carrie L.
    Dapena, Jesus
    Schrader, John
    JOURNAL OF ATHLETIC TRAINING, 2006, 41 (03) : 239 - 244
  • [9] A Clinical Device for Measuring Internal-External Rotational Laxity of the Knee
    Alam, Mahbub
    Bull, Anthony M. J.
    Thomas, Rhidian deW
    Amis, Andrew A.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2013, 41 (01): : 87 - 94
  • [10] Comparison of screw-home mechanism in the unloaded living knee subjected to active and passive movements
    Jeon, Jeong Woo
    Hong, Jiheon
    JOURNAL OF BACK AND MUSCULOSKELETAL REHABILITATION, 2021, 34 (04) : 589 - 595