Reinforcement of beams by using carbon fiber reinforced polimer in concrete buildings

被引:0
|
作者
Onal, M. Mustafa [1 ]
机构
[1] Ahi Evran Univ, Vocat Sch, TR-40100 Kir Ehir, Turkey
来源
SCIENTIFIC RESEARCH AND ESSAYS | 2009年 / 4卷 / 10期
关键词
Concrete structures; beam; reinforcement; strength; shear strength; CFRP COMPOSITES; SHEAR;
D O I
暂无
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Concrete beams, which have insufficient bending and shear strengths, were strengthened wrapping them with Carbon Fiber Reinforced Polimer (CFRP) in this study. The work was implemented on the rectangular section beams that were observed to requiring reinforcement after the examination and statistical analysis conducted. The aim was to strengthen beams that have insufficient shear strength values. Three among the nine used for the examination, was reinforced by using CFRP and epoxy in the tension surface whereas another three of them was reinforced by wrapping CRFP with 45 angle in the shear. The remaining three beams, on the other hand, were used as the reference beams. The reinforced beams were tested under the loading on the four points. The values were then compared with the reference beams' values. As a result of the test; the strength was observed to increase with a 40% whereas a small increase was determined when rigidity and energy consumption values were determined.
引用
收藏
页码:1136 / 1145
页数:10
相关论文
共 50 条
  • [42] Strengthening of negative moment region of reinforced concrete beams using carbon fiber-reinforced polymer strips
    Grace, NF
    [J]. ACI STRUCTURAL JOURNAL, 2001, 98 (03) : 347 - 358
  • [43] Maximum Shear Reinforcement of Reinforced Concrete Beams
    Windisch, Andor
    [J]. ACI STRUCTURAL JOURNAL, 2011, 108 (04) : 510 - 511
  • [44] Maximum Shear Reinforcement of Reinforced Concrete Beams
    Lee, Jung-Yoon
    Hwang, Hyun-Bok
    [J]. ACI STRUCTURAL JOURNAL, 2010, 107 (05) : 580 - 588
  • [45] Damage in fiber reinforced concrete beams
    Prochazka, P
    Dolezel, V
    [J]. DAMAGE AND FRACTURE MECHANICS VIII: COMPUTER AIDED ASSESSMENT AND CONTROL, 2004, 14 : 153 - 162
  • [46] Reinforcement of prismatic concrete columns using fiber reinforced plastics
    Calvo, I
    Mieres, J
    Bautista, S
    Rodríguez, J
    Viñolo, A
    Gutiérrez, E
    Loum, W
    [J]. COMPOSITES IN CONSTRUCTION, 2001, : 263 - 267
  • [47] Feasibility of reinforcement in Brazilian concrete highway bridges using carbon fiber-reinforced polymer
    Medeiros, A.
    Mazer, W.
    Rossigali, C. E.
    Bittencourt, T. N.
    [J]. MAINTENANCE, SAFETY, RISK, MANAGEMENT AND LIFE-CYCLE PERFORMANCE OF BRIDGES, 2018, : 354 - 357
  • [48] Consumption of carbon fiber plates in the reinforced concrete beams strengthened with CFPs
    Bu Liangtao
    Song Li
    Shi Chuxian
    [J]. FRONTIERS OF STRUCTURAL AND CIVIL ENGINEERING, 2007, 1 (04) : 393 - 398
  • [49] Study on electric property of partial carbon fiber reinforced concrete beams
    Dai, Hong-Zhe
    Wu, Si-Gang
    Wang, Wei
    [J]. Gongneng Cailiao/Journal of Functional Materials, 2006, 37 (SUPPL.): : 590 - 592
  • [50] BENDING PROPERTIES OF HIGH PERFORMANCE CARBON FIBER REINFORCED CONCRETE BEAMS
    Khalil, W. I.
    Mahmood, A. A.
    [J]. FIBRE CONCRETE 2011: TECHNOLOGY, DESIGN, APPLICATION, 2011, : 379 - 397