Determination of the critical absolute blood volume for intradialytic morbid events

被引:29
|
作者
Kron, Susanne [1 ]
Schneditz, Daniel [2 ]
Leimbach, Til [3 ]
Czerny, Jutta [3 ]
Aign, Sabine [3 ]
Kron, Joachim [3 ]
机构
[1] Charite, Dept Nephrol, D-13353 Berlin, Germany
[2] Med Univ Graz, Inst Physiol, Graz, Austria
[3] KfH Kidney Ctr Berlin Kopenick, Erwin Bock Str 5, D-12559 Berlin, Germany
关键词
Absolute blood volume; blood volume monitoring; hemodialysis; intradialytic morbid events; volume management; HEMODIALYSIS-PATIENTS; HYPOTENSION; DIALYSIS; MONITOR;
D O I
10.1111/hdi.12375
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
The reduction of blood volume below a critical threshold is assumed to trigger intradialytic morbid events (IME). Recently, we presented a simple method to determine the absolute blood volume during routine hemodialysis (HD) carried out without blood sampling and without injection of dyes or radiolabeled markers. Such information could be used to detect excessive volume reduction during HD and to prevent IME. Therefore, we performed a pilot study in IME-prone patients to identify the absolute blood volume at which they developed clinical symptoms. A volume of 240mL of ultrapure dialysate was automatically infused into the extracorporeal circulation using the bolus function of a commercial online hemodiafiltration machine incorporating a blood volume monitor (BVM). The increase in relative blood volume (RBV) caused by the infusion was measured and used to determine the absolute blood volume at that time. The blood volume per kilogram body mass at the time of symptomatic IME was also determined. All IME-prone patients of a single-dialysis center were included in the study. Ten out of 12 patients became symptomatic at a specific blood volume between 65 and 56mL/kg (mean 62mL/kg) whereas RBV showed a wide scatter (82-97%). A specific blood volume of 65mL/kg seems to represent the threshold for IME by this method. The technique could be completely automated without altering the hardware of the dialysis device. Present feedback systems for automated blood volume-controlled ultrafiltration could be adapted to maintain absolute blood volume above this critical volume to safely prevent volume-dependent IME.
引用
收藏
页码:321 / 326
页数:6
相关论文
共 50 条
  • [31] DETERMINATION OF BLOOD VOLUME
    EKELUND, LG
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1965, S 17 : 53 - &
  • [32] DETERMINATION OF BLOOD VOLUME
    不详
    LANCET, 1953, 264 (MAR14): : 529 - 529
  • [33] Determination of blood volume
    Bennett, I
    Wright, S
    Dow, J
    Floyd, WF
    Lander, FPL
    LANCET, 1938, 2 : 971 - 971
  • [34] Determination of blood volume
    Charnley, J
    LANCET, 1938, 2 : 806 - 806
  • [35] Relative blood volume changes underestimate absolute blood volume changes during hemodialysis
    Dasselaar, Judith
    Hooge, Marjolijn Lub-de
    Pruim, Jan
    Nijnuis, Hugo
    Wiersum, Anneke
    de Jong, Paul
    Huisman, Roel
    Franssen, Casper
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2007, 22 : 215 - 216
  • [36] PARAMETER ESTIMATOR AND ADAPTIVE CONTROLLER TO REGULATE INTRADIALYTIC BLOOD-VOLUME TRENDS
    SANTORO, A
    SPONGANO, M
    MANCINI, E
    ROSSI, M
    PAOLINI, F
    ZUCCHELLI, P
    KIDNEY INTERNATIONAL, 1992, 41 (05) : 1446 - 1447
  • [37] EFFECTS OF AUTOMATIC BLOOD-VOLUME CONTROL OVER INTRADIALYTIC HEMODYNAMIC STABILITY
    MANCINI, E
    SANTORO, A
    SPONGANO, M
    PAOLINI, F
    ZUCCHELLI, P
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1995, 18 (09): : 495 - 498
  • [38] Assessing Extracellular Volume in Hemodialysis Patients Using Intradialytic Blood Pressure Slopes
    Liu, Hao
    Lu, Rong
    Shastri, Shani
    Sonderman, Mark
    Van Buren, Peter Noel
    NEPHRON, 2018, 139 (02) : 120 - 130
  • [39] Improved intradialytic stability during haemodialysis with blood volume-controlled ultrafiltration
    Gabrielli, Danila
    Kristal, Batya
    Katzarski, Krassimir
    Youssef, Maan
    Hachache, Toufic
    Lopot, Frantisek
    Lasseur, Catherine
    Gunne, Thomas
    Draganov, Branimir
    Wojke, Ralf
    Gauly, Adelheid
    JOURNAL OF NEPHROLOGY, 2009, 22 (02) : 232 - 240
  • [40] The effects of extracellular volume and intradialytic peripheral resistance changes on ambulatory blood pressure in hemodialysis patients with and without recurrent intradialytic hypertension
    McAdams, Meredith
    Gregg, L. Parker
    Lu, Rong
    Concepcion, Michael
    Lederer, Swati
    Penfield, Jeff
    Van Buren, Peter Noel
    CLINICAL KIDNEY JOURNAL, 2021, 14 (05) : 1450 - 1457