Experimental and numerical study on the thermal performance of ground source heat pump with a set of designed buried pipes

被引:57
|
作者
Kong, Xiang-Ri [1 ]
Deng, Yelin [2 ]
Li, Linyan [3 ]
Gong, Wei-Shen [1 ]
Cao, Shi-Jie [1 ]
机构
[1] Soochow Univ, Dept Civil & Environm Engn, Sch Urban Rail Transportat, Suzhou, Peoples R China
[2] Univ Wisconsin, Dept Mech Engn, Milwaukee, WI 53211 USA
[3] Harvard TH Chan Sch Publ Hlth, Dept Environm Hlth, Boston, MA USA
关键词
Ground heat exchanger; Thermal performance; U-tubes; CFD; Turbulent heat diffusion; Pressure loss coefficient; ARTIFICIAL NEURAL-NETWORKS; U-TUBE; EXCHANGERS; SYSTEMS; SIMULATION;
D O I
10.1016/j.applthermaleng.2016.11.176
中图分类号
O414.1 [热力学];
学科分类号
摘要
The configuration of pipes is one of the most important factors for the thermal behavior of the Ground Source Heat Pump system (GSHPs). However, few studies have considered the influences of pipe shape in the perspective of turbulent diffusion and pressure loss effects. This paper investigates thermal performance of ground heat exchanger (GHE) with a set of designed U-tubes (i.e., either smooth or with different petals) by using experimental measurements and computational fluid dynamics (CFD) simulation. Thermal performance is based on temperature difference between inlet and outlet of U-tubes as well as the impact on the surrounding soil. First, an experiment (U-tubes buried with a depth of 100 m) was conducted to validate the CFD k-s RNG model for a smooth U-tube, which agrees well with experiments with suitable boundary conditions and appropriate parameters. Next, CFD simulation tool was mainly employed for other evaluations. Different inlet velocities of U-tubes were considered, and we found the heat transfer per unit borehole depth QL increases with the increase of inlet velocities, e.g., the QL of smooth U-tube was 35 W/m at inlet velocity of 0.2 m/s, and increased by 43% when the velocity was increased to 1.2 m/s. Although U-tubes with different petals would increase the turbulent heat diffusion effects, the flow resistance is also increased due to the increase of pressure loss coefficient, further leading to the declined advection effects on heat exchange. It is shown that the thermal performance of smooth U-tube at different velocities is always better than the petals type. Finally future design of guidelines is given in discussion. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:110 / 117
页数:8
相关论文
共 50 条
  • [41] The performance of ground source heat pipes at low constant source temperatures
    Ozsoy, Ahmet
    Yildirim, Ragip
    [J]. INTERNATIONAL JOURNAL OF GREEN ENERGY, 2018, 15 (11) : 641 - 650
  • [42] Random Analysis On Line-Heat Source Temperature Field Of Ground Source Heat Pumps Buried Pipes
    Guan, Changsheng
    Liu, Zhuodong
    Xia, Kai
    Chen, Xuyi
    [J]. ICIC 2009: SECOND INTERNATIONAL CONFERENCE ON INFORMATION AND COMPUTING SCIENCE, VOL 4, PROCEEDINGS, 2009, : 366 - 369
  • [43] A Numerical Study on the Performance of Ground Heat Exchanger Buried in Fractured Rock Bodies
    Zhou, Weisong
    Pei, Peng
    Hao, Dingyi
    Wang, Chen
    [J]. ENERGIES, 2020, 13 (07)
  • [44] Performance Study of a Hybrid Heat Pump Dryer based on Numerical Analysis and Experimental Set-up
    SHAMSUDDEENMohamedMurshid
    CHADong-An
    KIMSeon-Chang
    KANEMOTOToshiaki
    KIMJin-Hyuk
    [J]. Journal of Thermal Science, 2021, 30 (01) : 111 - 122
  • [45] Experimental study of vertical ground-source heat pump performance evaluation for cold climate in Turkey
    Ozyurt, Omer
    Ekinci, Dundar Arif
    [J]. APPLIED ENERGY, 2011, 88 (04) : 1257 - 1265
  • [46] Performance Study of a Hybrid Heat Pump Dryer based on Numerical Analysis and Experimental Set-up
    Shamsuddeen, Mohamed Murshid
    Cha, Dong-An
    Kim, Seon-Chang
    Kanemoto, Toshiaki
    Kim, Jin-Hyuk
    [J]. JOURNAL OF THERMAL SCIENCE, 2021, 30 (01) : 111 - 122
  • [47] Performance Study of a Hybrid Heat Pump Dryer based on Numerical Analysis and Experimental Set-up
    Mohamed Murshid Shamsuddeen
    Dong-An Cha
    Seon-Chang Kim
    Toshiaki Kanemoto
    Jin-Hyuk Kim
    [J]. Journal of Thermal Science, 2021, 30 : 111 - 122
  • [48] Experimental research on ground source heat pump system
    He Duanlian
    Liu Qiming
    Yang Lin
    [J]. PROCEEDINGS OF ISES SOLAR WORLD CONGRESS 2007: SOLAR ENERGY AND HUMAN SETTLEMENT, VOLS I-V, 2007, : 2547 - 2551
  • [49] Research on the Experimental Platform of Ground Source Heat Pump
    Xu Zhaokang
    Cheng Daolai
    Wang Bo
    [J]. CIVIL, STRUCTURAL AND ENVIRONMENTAL ENGINEERING, PTS 1-4, 2014, 838-841 : 1944 - 1948
  • [50] Simulation study on the thermal performance of vertical U-tube heat exchangers for ground source heat pump system
    Pu, Liang
    Qi, Di
    Li, Kang
    Tan, Hongbo
    Li, Yanzhong
    [J]. APPLIED THERMAL ENGINEERING, 2015, 79 : 202 - 213