Experimental and numerical study on the thermal performance of ground source heat pump with a set of designed buried pipes

被引:57
|
作者
Kong, Xiang-Ri [1 ]
Deng, Yelin [2 ]
Li, Linyan [3 ]
Gong, Wei-Shen [1 ]
Cao, Shi-Jie [1 ]
机构
[1] Soochow Univ, Dept Civil & Environm Engn, Sch Urban Rail Transportat, Suzhou, Peoples R China
[2] Univ Wisconsin, Dept Mech Engn, Milwaukee, WI 53211 USA
[3] Harvard TH Chan Sch Publ Hlth, Dept Environm Hlth, Boston, MA USA
关键词
Ground heat exchanger; Thermal performance; U-tubes; CFD; Turbulent heat diffusion; Pressure loss coefficient; ARTIFICIAL NEURAL-NETWORKS; U-TUBE; EXCHANGERS; SYSTEMS; SIMULATION;
D O I
10.1016/j.applthermaleng.2016.11.176
中图分类号
O414.1 [热力学];
学科分类号
摘要
The configuration of pipes is one of the most important factors for the thermal behavior of the Ground Source Heat Pump system (GSHPs). However, few studies have considered the influences of pipe shape in the perspective of turbulent diffusion and pressure loss effects. This paper investigates thermal performance of ground heat exchanger (GHE) with a set of designed U-tubes (i.e., either smooth or with different petals) by using experimental measurements and computational fluid dynamics (CFD) simulation. Thermal performance is based on temperature difference between inlet and outlet of U-tubes as well as the impact on the surrounding soil. First, an experiment (U-tubes buried with a depth of 100 m) was conducted to validate the CFD k-s RNG model for a smooth U-tube, which agrees well with experiments with suitable boundary conditions and appropriate parameters. Next, CFD simulation tool was mainly employed for other evaluations. Different inlet velocities of U-tubes were considered, and we found the heat transfer per unit borehole depth QL increases with the increase of inlet velocities, e.g., the QL of smooth U-tube was 35 W/m at inlet velocity of 0.2 m/s, and increased by 43% when the velocity was increased to 1.2 m/s. Although U-tubes with different petals would increase the turbulent heat diffusion effects, the flow resistance is also increased due to the increase of pressure loss coefficient, further leading to the declined advection effects on heat exchange. It is shown that the thermal performance of smooth U-tube at different velocities is always better than the petals type. Finally future design of guidelines is given in discussion. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:110 / 117
页数:8
相关论文
共 50 条
  • [1] Study on Design Calculation of Heat Exchange for Ground-Source Heat Pump Buried Pipes
    Liu Qiuxin
    Hu Zhongping
    Li Shensheng
    Yang Erping
    Ding Yun
    [J]. PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON ASIAN-EUROPEAN ENVIRONMENTAL TECHNOLOGY AND KNOWLEDGE TRANSFER, 2008, : 397 - 402
  • [2] GROUND SOURCE HEAT PUMP WITH HORIZONTAL GROUND BURIED PIPES: MODELLING AND OPTIMIZATION WITH TRNSYS
    Hou, Gaoyang
    Taherian, Hessam
    [J]. 2018 BUILDING PERFORMANCE ANALYSIS CONFERENCE AND SIMBUILD, 2018, : 607 - 614
  • [3] Calculation of heat exchange for ground-source heat pump from buried pipes
    Liu, Qiuxin
    Yang, Erping
    Gao, Chunxue
    Li, Yong
    [J]. PROCEEDINGS OF THE IAMG '07: GEOMATHEMATICS AND GIS ANALYSIS OF RESOURCES, ENVIRONMENT AND HAZARDS, 2007, : 640 - 640
  • [4] Heat exchange scheme simulation optimization for ground source heat pump system with buried pipes by thermal equilibrium analysis
    Luo, Zujiang
    Du, Jingjing
    [J]. Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering, 2018, 34 (13): : 246 - 254
  • [5] Experimental study of heat transfer of buried finned pipe for ground source heat pump applications
    Koyun, Ahmet
    Demir, Hakan
    Torun, Zakir
    [J]. INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2009, 36 (07) : 739 - 743
  • [6] EXPERIMENTAL AND NUMERICAL ANALYSIS OF THERMAL PERFORMANCE IN HEAT PIPES
    Nookaraju, B. Ch
    Rao, P. S. V. Kurma
    Nagasarada, S.
    [J]. INTERNATIONAL CONFERENCE ON COMPUTATIONAL HEAT AND MASS TRANSFER (ICCHMT) - 2015, 2015, 127 : 800 - 808
  • [7] Experimental investigation of thermal performance of a ground source heat pump system for spring season
    Mao, Qianjun
    Chen, Yufeng
    [J]. ENERGY AND BUILDINGS, 2017, 152 : 336 - 340
  • [8] Experimental thermal performance evaluation of a horizontal ground-source heat pump system
    Inalli, M
    Esen, H
    [J]. APPLIED THERMAL ENGINEERING, 2004, 24 (14-15) : 2219 - 2232
  • [9] Study on the heat transfer performance of boiling in vertical buried tube of direct expansion ground source heat pump
    Gao, Yuefen
    Gao, Tingling
    Liu, Zhao
    [J]. INNOVATIVE SOLUTIONS FOR ENERGY TRANSITIONS, 2019, 158 : 5494 - 5503
  • [10] The Experimental Thermal Performance Analysis of the Ground Source Heat Pump System Dependent on Environmental Conditions
    Karabacak, R.
    Acar, S. Gueven
    [J]. ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2010, 32 (12) : 1142 - 1158