The performance of the SPring-8 cryogenic cooling system was examined extensively, especially, on the features closely related to the actual experimental situations. The cryogenic cooling system has sufficient cooling capability to, handle the permitted highest heat load of 478 W at BL29XUL which equips the SPring-8 standard in-vacuum undulator. The effect of the heat load on the beam profile and the rocking curve width was reasonably small. The rocking curve width with Si 333 diffraction at 18.7 keV was close to the theoretical width 0.86". Thus the monochromator conserves the good spatial coherence originating from the small source size of the undulator. Mechanical vibrations at frequencies of 30-100 Hz degraded the parallelism between the two monochromator crystals. The angular width of the mechanical vibration was measured to be 0.2" independent of the heat load and the flow rate of the circulating liquid nitrogen. The output intensity was stable and had no drift under any heat load. On the other hand, it took a few hours before the output energy stabilized, when the heat load was increased from 0.135 to 112 W.
引用
收藏
页码:132 / 142
页数:11
相关论文
共 50 条
  • [1] Cryogenic cooling monochromators for the SPring-8 undualtor beamlines
    Mochizuki, T
    Kohmura, Y
    Awaji, A
    Suzuki, Y
    Baron, A
    Tamasaku, K
    Yabashi, M
    Yamazaki, H
    Ishikawa, T
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 647 - 649
  • [2] SPring-8 standard x-ray monochromators
    Yabashi, M
    Yamazaki, H
    Tamasaku, K
    Goto, S
    Takeshita, K
    Mochizuki, T
    Yoneda, Y
    Furukawa, Y
    Ishikawa, T
    [J]. X-RAY OPTICS DESIGN, PERFORMANCE, AND APPLICATIONS, 1999, 3773 : 2 - 13
  • [3] Improvement in stability of SPring-8 X-ray monochromators with cryogenic-cooled silicon crystals
    Yamazaki, Hiroshi
    Ohashi, Haruhiko
    Senba, Yasunori
    Takeuchi, Tomoyuki
    Shimizu, Yasuhiro
    Tanaka, Masayuki
    Matsuzaki, Yasuhisa
    Kishimoto, Hikaru
    Miura, Takanori
    Terada, Yasuko
    Suzuki, Motohiro
    Tajiri, Hiroo
    Goto, Shunji
    Yamamoto, Masaki
    Takata, Masaki
    Ishikawa, Tetsuya
    [J]. 11TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI 2012), 2013, 425
  • [4] Improvement in Stability of SPring-8 Standard X-Ray Monochromators with Water-Cooled Crystals
    Yamazaki, Hiroshi
    Shimizu, Yasuhiro
    Miura, Takanori
    Tanaka, Masayuki
    Kishimoto, Hikaru
    Matsuzaki, Yasuhisa
    Shimizu, Nobtaka
    Kawano, Yoshiaki
    Kumasaka, Takashi
    Yamamoto, Masaki
    Koganezawa, Tomoyuki
    Sato, Masugu
    Hirosawa, Ichiro
    Senba, Yasunori
    Ohashi, Haruhiko
    Goto, Shunji
    Ishikawa, Tetsuya
    [J]. SRI 2009: THE 10TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION, 2010, 1234 : 785 - +
  • [5] Cryogenically cooled monochromator with multi-crystal switching system on BL11XU at SPring-8
    Shiwaku, H
    Mitsui, T
    Tozawa, K
    Kiriyama, K
    Harami, T
    Mochizuki, T
    [J]. SYNCHROTRON RADIATION INSTRUMENTATION, 2004, 705 : 659 - 662
  • [6] Cryogenically Cooled Monochromator with Multi-crystal Switching System on BL11XU at SPring-8
    Shiwaku, Hideaki
    Mitsui, Takaya
    Tozawa, Kazukiyo
    Kiriyama, Koji
    Harami, Taikan
    Mochizuki, Tetsuro
    [J]. AIP Conf. Proc., 1600, (659-662):
  • [7] Performance limits of indirectly cryogenically cooled silicon monochromators - experimental results at the APS
    Lee, WK
    Fezzaa, K
    Fernandez, P
    Tajiri, G
    Mills, D
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 2001, 8 (01) : 22 - 25
  • [8] Performance limits of direct cryogenically cooled silicon monochromators - experimental results at the APS
    Lee, WK
    Fernandez, P
    Mills, DM
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 2000, 7 : 12 - 17
  • [9] Angular vibrations of cryogenically cooled double-crystal monochromators
    Sergueev, I.
    Doehrmann, R.
    Horbach, J.
    Heuer, J.
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 2016, 23 : 1097 - 1103
  • [10] Present status of stability improvement of SPring-8 standard x-ray monochromators
    Yamazaki, Hiroshi
    Shimizu, Yasuhiro
    Shimizu, Nobutaka
    Kawamoto, Masahide
    Kawano, Yoshiaki
    Senba, Yasunori
    Ohashi, Haruhiko
    Goto, Shunji
    [J]. ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS III, 2008, 7077