Simultaneous determination of methamphetamine and its metabolite, amphetamine, in urine using a high performance liquid chromatography column-switching method

被引:40
|
作者
Kumihashi, Mitsuru
Ameno, Kiyoshi
Shibayama, Takayuki
Suga, Keisuke
Miyauchi, Hiroshi
Jamal, Mostofa
Wang, Weihuan
Uekita, Ikuo
Ijiri, Iwao
机构
[1] Kagawa Univ, Fac Med, Dept Forens Med, Miki, Kagawa 7610793, Japan
[2] Kagawa Prefecture Police Headquarters, Forens Sci Lab, Takamatsu, Kagawa 7608579, Japan
关键词
HPLC; column-switching; methamphetamine; amphetamine; urine;
D O I
10.1016/j.jchromb.2006.07.049
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We describe here a simple, precise, and highly sensitive method for the simultaneous determination of methamphetamine (MA) and amphetamine (AM) in urine using a high performance liquid chromatography (HPLC) column-switching method. A PK-2A (Shodex) column was used for extraction and deproteinization, and a CAPCELL PAK SCX semi-micro, polymer-coated cation-exchange column was employed for separation. The urine sample was mixed with an equal volume of borate buffer (0.1 M, pH 9.4), and then 100 mu l of the mixture was injected into the HPLC column. The column was switched for 6 min, and then 10 min later detection was performed at 210 nm. Recovery yields of the MA and AM spiked in the urine were 93.0-100.4% with a coefficient of variation of less than 1%. The calibration curves of MA and AM were in the range of 0.1-10 mu g/ml with good linearity (r(2) = 0.999), with the limit of qualification being 0.005 mu g/ml. This method of using HPLC with column-switching can be used for both qualification and quantification of MA and its metabolite, AM, in urine, especially in forensic cases. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:180 / 183
页数:4
相关论文
共 50 条
  • [21] Sensitive column-switching high-performance liquid chromatography method for determination of propiverine in human plasma
    Ban, EM
    Maeng, JE
    Woo, JS
    Kim, CK
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 831 (1-2): : 230 - 235
  • [22] SIMULTANEOUS DETERMINATION OF AMPICILLIN AND METAMPICILLIN IN BIOLOGICAL-FLUIDS USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH COLUMN-SWITCHING
    LEE, HY
    LEE, JS
    LEE, HS
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 664 (02): : 335 - 340
  • [23] Automated high-performance liquid chromatographic determination of amphetamine in biological fluids using column-switching and on-column derivatization
    R. Herráez-Hernández
    P. Campíns-Falcó
    S. Díaz-Oltra
    Chromatographia, 1999, 49 : 188 - 196
  • [24] Automated high-performance liquid chromatographic determination of amphetamine in biological fluids using column-switching and on-column derivatization
    Herráez-Hernández, R
    Campíns-Falcó, P
    Díaz-Oltra, S
    CHROMATOGRAPHIA, 1999, 49 (3-4) : 188 - 196
  • [25] Determination of ibuprofen enantiomers in human plasma by column-switching high performance liquid chromatography
    Xiang Jin
    Yu Qin
    Liang Mao-Zhi
    Qin Yong-Ping
    Nan Feng
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2008, 36 (03) : 311 - 315
  • [26] Direct Determination of Benzamides in Serum by Column-Switching High-Performance Liquid Chromatography
    Ryoko Chiba
    Ayako Ogasawara
    Teppei Kubo
    Hiroyuki Yamazaki
    Masuo Umino
    Yoichi Ishizuka
    Analytical Sciences, 2003, 19 : 785 - 789
  • [27] A COLUMN-SWITCHING TECHNIQUE FOR THE SCREENING OF DIURETICS IN URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    SAARINEN, M
    SIREN, H
    RIEKKOLA, ML
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1993, 16 (18): : 4063 - 4078
  • [29] Direct determination of benzamides in serum by column-switching high-performance liquid chromatography
    Chiba, R
    Ogasawara, A
    Kubo, T
    Yamazaki, H
    Umino, M
    Ishizuka, Y
    ANALYTICAL SCIENCES, 2003, 19 (05) : 785 - 789
  • [30] Determination of myristicin in rat serum samples using microbore high performance liquid chromatography with column-switching
    Lee, HS
    Kim, JH
    Kim, K
    Do, KS
    CHROMATOGRAPHIA, 1998, 48 (5-6) : 365 - 368