A batch microfabrication of a microfluidic electrochemical sensor for rapid chemical oxygen demand measurement

被引:1
|
作者
Yin, Jiawen [1 ]
Zhang, Zan [1 ]
Zhang, Xin [1 ]
Mai, Yuliang [2 ,3 ]
Luan, Anbo [2 ,3 ]
Xu, Baojian [4 ,5 ]
Jin, Qinghui [1 ,4 ,5 ]
机构
[1] Ningbo Univ, Fac Elect Engn & Comp Sci, Ningbo 315211, Peoples R China
[2] Guangdong Key Lab Ind Surfactant, Guangzhou 510665, Peoples R China
[3] Guangdong Res Inst Petrochem & Fine Chem Engn, Guangzhou 510665, Peoples R China
[4] Chinese Acad Sci, Shanghai Inst Microsyst & Informat Technol, State Key Labs Transducer Technol, Shanghai 200050, Peoples R China
[5] Chinese Acad Sci, Shanghai Inst Microsyst & Informat Technol, Sci & Technol Microsyst Lab, Shanghai 200050, Peoples R China
基金
美国国家科学基金会;
关键词
D O I
10.1039/d0an02133d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Chemical oxygen demand (COD) is one of the key water quality parameters in environmental monitoring. However, fabricating a COD sensor with the characteristic of batch-processing and rapid measurement is always a challenging issue. This paper reports a microfluidic electrochemical sensor for the organic matter measurement based on advanced oxidization within a fixed microvolume detection chamber by a microfabrication technique/MEMS. By fabricating a silicon-based Ag/AgCl reference electrode and employing PbO2 as the working electrode with Pt as the counter electrode, we verified the superiority of the as-fabricated sensor by continuous potassium acid phthalate detection; an acceptable limit of detection (4.17 mg L-1-200 mg L-1), a low limit of detection (2.05 mg L-1), a desirable linearity (R-2 = 0.982) and relative stability at different pH values and Cl- concentrations was witnessed. Particularly, a shorter detection time (2 s) was witnessed for the as-proposed sensor compared with traditional organic matter measurement methods. Each sensing process takes only 2 seconds for sensing because a micro-cavity with a volume of 2.5 mu L was fabricated and used as a detection pool. Moreover, as the sensor was fabricated by a mass-production technique, potential response consistency of multiple sensors was expected and was verified via a series of parallel experiments. In this paper, a miniaturized (8 mm x 10 mm), low-cost and reliable COD sensor was designed and fabricated by MEMS, and it provided a core sensor component for construction of an online water environment monitoring network to meet the substantial demand for COD sensors in the Internet of Things (IOT) era.
引用
收藏
页码:1956 / 1964
页数:9
相关论文
共 50 条
  • [31] Preparation of Electrochemical Sensor Based on Morphology-Controlled Platinum Nanoparticles for Determination of Chemical Oxygen Demand
    Wu Can
    Wu Kang-Bing
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 41 (05) : 704 - 708
  • [32] Chemical oxygen demand (COD) sensor using a stopped-flow thin layer electrochemical cell
    Lee, KH
    Ishikawa, T
    Sasaki, S
    Arikawa, Y
    Karube, I
    ELECTROANALYSIS, 1999, 11 (16) : 1172 - 1179
  • [33] Compact fluidic electrochemical sensor platform for on-line monitoring of chemical oxygen demand in urban wastewater
    Duan, Wenchao
    Gunes, Murat
    Baldi, Antonio
    Gich, Marti
    Fernandez-Sanchez, Cesar
    CHEMICAL ENGINEERING JOURNAL, 2022, 449
  • [34] Rapid Potentiometric Detection of Chemical Oxygen Demand Using a Portable Self-Powered Sensor Chip
    Hao, Nan
    Dai, Zhen
    Xiong, Meng
    Han, Xu
    Zuo, Yanli
    Qian, Jing
    Wang, Kun
    ANALYTICAL CHEMISTRY, 2021, 93 (24) : 8393 - 8398
  • [35] CONTINUOUS MONITORING-SYSTEM OF CHEMICAL OXYGEN-DEMAND AT MICRO SCALE BASED ON ELECTROCHEMICAL MEASUREMENT
    GOTO, M
    SHIROEDA, T
    ISHII, D
    BUNSEKI KAGAKU, 1981, 30 (06) : 403 - 407
  • [36] Rapid determination of chemical oxygen demand in grape sugar.
    Sun, JM
    Li, LH
    Sun, HW
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2004, 228 : U229 - U229
  • [37] A Nafion Film Cover to Enhance the Analytical Performance of the CuO/Cu Electrochemical Sensor for Determination of Chemical Oxygen Demand
    Carchi, Tanya
    Lapo, Byron
    Alvarado, Jose
    Espinoza-Montero, Patricio J.
    Llorca, Jordi
    Fernandez, Lenys
    SENSORS, 2019, 19 (03):
  • [38] Sensitive and Green Method for Determination of Chemical Oxygen Demand Using a Nano-copper Based Electrochemical Sensor
    Badr, Ibrahim H. A.
    Hassan, Hamdy H.
    Hamed, E.
    Abdel-Aziz, Ali M.
    ELECTROANALYSIS, 2017, 29 (10) : 2401 - 2409
  • [39] Rapid alternative determination of chemical oxygen demand by microwave digestion
    Houser, J
    Kristakova, J
    CHEMICKE LISTY, 1997, 91 (05): : 377 - 380
  • [40] Portable Photoelectrochromic Visualization Sensor for Detection of Chemical Oxygen Demand
    Dai, Zhen
    Hao, Nan
    Xiong, Meng
    Han, Xu
    Zuo, Yanli
    Wang, Kun
    ANALYTICAL CHEMISTRY, 2020, 92 (19) : 13604 - 13609