Mesh morphing for finite element analysis of implant positioning in cementless total hip replacements

被引:33
|
作者
Bah, Mamadou T. [1 ]
Nair, Prasanth B. [1 ]
Browne, Martin [1 ]
机构
[1] Univ Southampton, Bioengn Sci Res Grp, Sch Engn Sci, Southampton SO17 1BJ, Hants, England
基金
英国工程与自然科学研究理事会;
关键词
Finite element mesh; Morphing; Cementless hip replacement; Implant positioning; STABILITY; MODELS;
D O I
10.1016/j.medengphy.2009.08.001
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Finite element (FE) analysis of the effect of implant positioning on the performance of cementless total hip replacements (THRs) requires the generation of multiple meshes to account for positioning variability. This process can be labour intensive and time consuming as CAD operations are needed each time a specific orientation is to be analysed. In the present work, a mesh morphing technique is developed to automate the model generation process. The volume mesh of a baseline femur with the implant in a nominal position is deformed as the prosthesis location is varied. A virtual deformation field, obtained by solving a linear elasticity problem with appropriate boundary conditions, is applied. The effectiveness of the technique is evaluated using two metrics: the percentages of morphed elements exceeding an aspect ratio of 20 and an angle of 165 degrees between the adjacent edges of each tetrahedron. Results show that for 100 different implant positions, the first and second metrics never exceed 3% and 3.5%, respectively. To further validate the proposed technique, FE contact analyses are conducted using three selected morphed models to predict the strain distribution in the bone and the implant micromotion under joint and muscle loading. The entire bone strain distribution is well captured and both percentages of bone volume with strain exceeding 0.7% and bone average strains are accurately computed. The results generated from the morphed mesh models correlate well with those for models generated from scratch, increasing confidence in the methodology. This morphing technique forms an accurate and efficient basis for FE based implant orientation and stability analysis of cementless hip replacements. (C) 2009 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1235 / 1243
页数:9
相关论文
共 50 条
  • [41] Total hip arthroplasty by using a cementless ultrashort stem: A subject-specific finite element analysis for a young patient clinical case
    Epasto, Gabriella
    Foti, Albina
    Guglielmino, Eugenio
    Rosa, Michele A.
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2013, 227 (07) : 757 - 766
  • [42] Biomechanical Evaluation of Screw-In Femoral Implant in Cementless Total Hip System
    Kim, James Y.
    Hayashi, Kei
    Garcia, Tanya C.
    Kim, Sun-Young
    Entwistle, Rachel
    Kapatkin, Amy S.
    Stover, Susan M.
    [J]. VETERINARY SURGERY, 2012, 41 (01) : 94 - 102
  • [43] The assessment of implant shape-dependent failure mechanisms in primary total hip arthroplasty using finite element analysis
    Kazemirad, Siavash
    Yazdi, Mohammad Ali
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2024,
  • [44] Influence of PEEK Coating on Hip Implant Stress Shielding: A Finite Element Analysis
    Anguiano-Sanchez, Jesica
    Martinez-Romero, Oscar
    Siller, Hector R.
    Diaz-Elizondo, Jose A.
    Flores-Villalba, Eduardo
    Rodriguez, Ciro A.
    [J]. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2016, 2016
  • [45] Finite element modeling of hip implant static loading
    Colic, Katarina
    Sedmak, Aleksandar
    Grbovic, Aleksandar
    Tatic, Uros
    Sedmak, Simon
    Djordjevic, Branislav
    [J]. INTERNATIONAL CONFERENCE ON MANUFACTURING ENGINEERING AND MATERIALS, ICMEM 2016, 2016, 149 : 257 - 262
  • [46] Supplementary finite element analysis in experimental testing of total hip stems
    Kluess, Daniel
    Lange, Hans-E
    Heyer, Horst
    Sander, Manuela
    Mittelmeier, Wolfram
    Bader, Rainer
    [J]. MATERIALS TESTING, 2018, 60 (05) : 489 - 494
  • [47] Finite Element Analysis of Proximal Cement Fixation in Total Hip Arthroplasty
    Ahmad, Maizatul Afirah
    Zulkifli, Nurul Nadhirah Mohamed Elias
    Shuib, Solehuddin
    Sulaiman, Shahrul Hisham
    Abdullah, Abdul Halim
    [J]. INTERNATIONAL JOURNAL OF TECHNOLOGY, 2020, 11 (05): : 1046 - 1055
  • [48] Influence of pelvic shape on strain patterns: A computational analysis using finite element mesh morphing techniques
    Salo, Zoryana
    Kreder, Hans
    Whyne, Cari Marisa
    [J]. JOURNAL OF BIOMECHANICS, 2021, 116
  • [49] Numerical analysis of the loosened total hip replacements (THR)
    Nedoma, J
    Bartos, M
    Hornátova, H
    Kestranek, Z
    Stehlík, J
    [J]. MATHEMATICS AND COMPUTERS IN SIMULATION, 1999, 50 (1-4) : 285 - 304
  • [50] Finite element modeling of the human kidney for probabilistic occupant models: Statistical shape analysis and mesh morphing
    Yates, Keegan M.
    Untaroiu, Costin D.
    [J]. JOURNAL OF BIOMECHANICS, 2018, 74 : 50 - 56