Analysis of the Usefulness of Optical Coherence Tomography and Intravascular Ultrasonography for the Examination of Rabbit Atherosclerotic Plaques

被引:1
|
作者
Zhang, Huawei [1 ]
Zhang, Shanchun [2 ]
Wang, Peng [3 ]
Wang, Jinda [1 ]
Yi, Guiyan [4 ]
Zhou, Ying [1 ]
Chen, Yundai [1 ]
机构
[1] Peoples Liberat Army Gen Hosp, Dept Cardiol, 28 Fuxing Rd, Beijing 100853, Peoples R China
[2] Peoples Liberat Army Gen Hosp, Dept Neurol, Beijing, Peoples R China
[3] Dezhou Peoples Hosp, Dept Cardiol, Dezhou, Peoples R China
[4] Beijing Mil Gen Hosp, Dept Cardiol, Beijing, Peoples R China
关键词
OCT; IVUS; atherosclerosis; pathology; rabbit; THIN-CAP FIBROATHEROMA; CORONARY ATHEROSCLEROSIS; CLINICAL-APPLICATIONS; ULTRASOUND; PROGRESSION; OCT; ARTERY; MODEL; IVUS; VIVO;
D O I
10.1097/RUQ.0000000000000167
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In the present study, we aimed to establish a rabbit atherosclerosis model and examine atherosclerotic plaques by using optical coherence tomography (OCT) and intravascular ultrasonography (IVUS) to evaluate the clinical usefulness of these diagnostic tools in the detection of atherosclerotic plaques. Twenty healthy New Zealand rabbits were fed on a high-fat diet for 4 weeks and then subjected to abdominal aortic intimal injury. The OCT and IVUS were performed after 8 weeks. The distal and proximal plaque images were marked to observe the plaque thickness and features of the lesions at the tunica intima and tunica media. Moreover, a pathological examination was performed to evaluate the efficacies of OCT and IVUS. The mean (SD) plaque thickness on OCT and IVUS images was 386.5 (125.3) m and 412.7 (165.8) m, respectively. Pathological examinations indicated a mean (SD) plaque thickness of 360.2 (98.l) m (P > 0.05). No significant differences were noted between the 2 methods. The intimal and medial thickness measured with OCT showed greater correlation with pathologically measured thickness (r = 0.95, P < 0.001 for OCT; r = 0.88, P < 0.001 for IVUS); in particular, the intimal thickness measurements on OCT showed a higher correlation (r = 0.98, P < 0.001). However, the measurements obtained using IVUS were not accurate. Thus, compared with IVUS, OCT was more accurate in determining the nature and thickness of vascular plaques.
引用
收藏
页码:75 / 81
页数:7
相关论文
共 50 条
  • [41] A Survey on Coronary Atherosclerotic Plaque Tissue Characterization in Intravascular Optical Coherence Tomography
    Alberto Boi
    Ankush D. Jamthikar
    Luca Saba
    Deep Gupta
    Aditya Sharma
    Bruno Loi
    John R. Laird
    Narendra N. Khanna
    Jasjit S. Suri
    [J]. Current Atherosclerosis Reports, 2018, 20
  • [42] A Survey on Coronary Atherosclerotic Plaque Tissue Characterization in Intravascular Optical Coherence Tomography
    Boi, Alberto
    Jamthikar, Ankush D.
    Saba, Luca
    Gupta, Deep
    Sharma, Aditya
    Loi, Bruno
    Laird, John R.
    Khanna, Narendra N.
    Suri, Jasjit S.
    [J]. CURRENT ATHEROSCLEROSIS REPORTS, 2018, 20 (07)
  • [43] ASSESSING ATHEROSCLEROTIC PLAQUE MORPHOLOGY, COMPARISON OF OPTICAL COHERENCE TOMOGRAPHY AND INTRAVASCULAR ULTRASOUND
    BREZINSKI, ME
    TEARNEY, GJ
    WEISSMAN, NJ
    BOPPART, SA
    BOUMA, BE
    HEE, MD
    WEYMAN, AE
    SWANSON, EA
    SOUTHERN, JF
    FUJIMOTO, JG
    [J]. CIRCULATION, 1995, 92 (08) : 705 - 705
  • [44] In Vivo Comparison of Fourier-Domain Optical Coherence Tomography and Intravascular Ultrasonography
    Ramesh, Sathyadeepak
    Papayannis, Aristotelis
    Abdel-karim, Abdul-rahman
    Banerjee, Subhash
    Brilakis, Emmanouil
    [J]. JOURNAL OF INVASIVE CARDIOLOGY, 2012, 24 (03): : 111 - 115
  • [45] Multimodality Optical Imaging of Atherosclerotic Plaques Combining Optical Coherence Tomography and Fluorescence Lifetime Imaging
    Jo, Javier A.
    Applegate, Brian E.
    Trivedi, Chintan A.
    Thomas, Patrick
    Jacob, Desmond
    Shelton, Ryan
    Clubb, Fred
    Keller, Brandis
    [J]. 2009 CONFERENCE ON LASERS AND ELECTRO-OPTICS AND QUANTUM ELECTRONICS AND LASER SCIENCE CONFERENCE (CLEO/QELS 2009), VOLS 1-5, 2009, : 399 - +
  • [46] Intravascular Optical Coherence Tomography Image Analysis Method
    Shalev, Ronny
    Prabhu, David
    Tanaka, Kentaro
    Rollins, Andrew M.
    Costa, Marco
    Bezerra, Hiram G.
    Soumya, Ray
    Wilson, David L.
    [J]. 2015 41ST ANNUAL NORTHEAST BIOMEDICAL ENGINEERING CONFERENCE (NEBEC), 2015,
  • [47] Validation of a New Animal Model of Vulnerable Plaques by Intravascular Optical Coherence Tomography In Vivo
    Fang, Yan
    Hu, Sining
    Hou, Jingbo
    Meng, Lingbo
    Zhang, Shaosong
    Yu, Bo
    [J]. JOURNAL OF BIOMEDICINE AND BIOTECHNOLOGY, 2012,
  • [48] Optical Coherence Tomography Features of Attenuated Plaques Detected by Grayscale-Intravascular Ultrasound
    Aoki, Hiroshi
    Kubo, Takashi
    Orii, Makoto
    Shiono, Yasutsugu
    Shimamura, Kunihiro
    Ishibashi, Kohei
    Yamano, Takashi
    Tanimoto, Takashi
    Ino, Yasushi
    Yamaguchi, Tomoyuki
    Imanishi, Toshio
    Akasaka, Takashi
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2012, 109 (07): : 47S - 47S
  • [49] Identification of vulnerable plaques by optical coherence tomography; a comparison with intravascular ultrasound and coronary angioscopy
    Takarada, S.
    Kubo, T.
    Yamano, T.
    Matsuo, Y.
    Masho, T.
    Hayashi, Y.
    Tomobuchi, Y.
    Akasaka, T.
    [J]. EUROPEAN HEART JOURNAL, 2006, 27 : 582 - 582
  • [50] Macrophage degradation in coronary atherosclerotic plaques by statin therapy: an optical coherence tomography study
    Nishiguchi, T.
    Kubo, T.
    Komukai, K.
    Matsuo, Y.
    Ino, Y.
    Hitrata, K.
    Tanaka, A.
    Hozumi, T.
    Akasaka, T.
    [J]. EUROPEAN HEART JOURNAL, 2015, 36 : 677 - 678