Impact of a quality improvement programme based on vascular access flow monitoring on costs, access occlusion and access failure

被引:34
|
作者
Wijnen, Edwin
Planken, Nils
Keuter, Xavier
Kooman, Jeroen P.
Tordoir, Jan H. M.
de Haan, Michiel W.
Leunissen, Karel M. L.
van der Sande, Frank
机构
[1] Univ Hosp Maastricht, Dept Internal Med & Nephrol, NL-6202 AZ Maastricht, Netherlands
[2] Univ Hosp Maastricht, Dept Surg, Maastricht, Netherlands
[3] Univ Hosp Maastricht, Dept Radiol, Maastricht, Netherlands
关键词
D O I
10.1093/ndt/gfl424
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
Background. Vascular access thrombosis is a substantial source of morbidity in chronic haemodialysis patients. Periodical access flow measurements can predict the presence of vascular access stenosis and provide an opportunity for early intervention to prevent subsequent vascular access thrombosis. By this system of quality improvement, vascular access-related costs might be reduced. The aim of this study was to analyse the cost impact of a quality improvement programme based on periodic access flow measurements. Methods. The number and costs of vascular access interventions (summary of angiography, percutaneous transluminal angioplasty, catheter placement, hospitalization days and costs for surgery) in the period 2001-2003 (quality improvement period; QIP, 218.6 patient-years observed) were retrospectively compared with a reference period (RP, 1996-1998, 214.4 patient-years observed) during which no access flow was measured. All access flow measurements were done on a regular base and interventions were performed according to the Kidney Disease Outcome Quality Initiative. Results. Surgical thrombectomy procedures were significantly less during the QIP (0.25 +/- 0.57 events/patient-year) compared with RP (0.63 +/- 1.06 events/patient-year; P = 0.000), whereas access loss was not significantly different. During the QIP, 205 radiological interventions were performed (0.88 +/- 1.16 events/patient-year), and in the RP around 48 (0.33 +/- 0.65 events/patient-year; P = 0.000). Access-related costs tended to be lower during the QIP compared with the RP. The cost reduction appeared to be limited to patients with arteriovenous graft (AVG), in which access-related costs were significantly lower during the QIP (e2360.95 +/- 2838.17 patient-year) compared with the RP (e4003.96 +/- 3810.92 patient-year; P = 0.012), but not in patients with arteriovenous fistula (AVF). Conclusion. A quality improvement programme based on periodical access flow measurement reduced the number of acute vascular access failures due to thrombotic events and also significantly reduced health care costs in patients with AVG, but not in patients with AVF. The quality improvement programme had no effect on access survival.
引用
收藏
页码:3514 / 3519
页数:6
相关论文
共 50 条
  • [41] Vascular access and fluoroscopy in percutaneous coronary interventions: A quality improvement project
    VerLee, P
    Hofmaster, P
    Silver, T
    Eigen, PV
    Rowe, M
    Gallupe, C
    Piper, W
    Malenka, D
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) : 62A - 62A
  • [42] Improvement of hemodialysis vascular access blood flow rate with angioplasty: Results from a vascular access surveillance program using transonics.
    Nassar, GM
    Achkar, K
    Suki, WN
    Brennan, S
    Gonzalez, JM
    Khan, AJ
    Rhee, E
    Campbell, J
    Jameyson, P
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2003, 14 : 723A - 723A
  • [43] Sentinel vascular access monitoring after endovascular intervention predicts access outcome
    Kumbar, Lalathaksha
    Peterson, Ed
    Zaborowicz, Matthew
    Besarab, Anatole
    Yee, Jerry
    Zasuwa, Gerard
    [J]. JOURNAL OF VASCULAR ACCESS, 2019, 20 (04): : 409 - 416
  • [44] THE ARM AS AN ALTERNATIVE SITE FOR VASCULAR ACCESS FOR DIALYSIS IN PATIENTS WITH RECURRENT ACCESS FAILURE
    HILL, SL
    SEEGER, JM
    [J]. SOUTHERN MEDICAL JOURNAL, 1985, 78 (01) : 37 - 40
  • [45] The prevention of access failure - Pressure monitoring
    Besarab, A
    Frinak, S
    [J]. ASAIO JOURNAL, 1998, 44 (01) : 35 - 37
  • [46] Quality of vascular access on chronic haemodialysis
    Stoeter, K.
    Bucher, C.
    Wolff, T.
    Thalhammer, C.
    Garzoni, D.
    Aschwanden, M.
    Eugster, T.
    Breidthardt, T.
    Steiger, J.
    Guerke, L.
    Mayr, M.
    [J]. SWISS MEDICAL WEEKLY, 2008, 138 (47-48) : 20S - 20S
  • [47] Monitoring the impact of hospital downsizing on access to care and quality of care
    Brownell, MD
    Roos, NP
    Burchill, C
    [J]. MEDICAL CARE, 1999, 37 (06) : JS135 - JS150
  • [48] Quality assessment of vascular access procedures for hemodialysis: A position paper of the Vascular Access Society based on the analysis of existing guidelines
    Fila, Branko
    Roca-Tey, Ramon
    Malik, Jan
    Malovrh, Marko
    Pirozzi, Nicola
    Kusztal, Mariusz
    Gallieni, Maurizio
    Jemcov, Tamara
    [J]. JOURNAL OF VASCULAR ACCESS, 2020, 21 (02): : 148 - 153
  • [49] THE DIFFERENTIAL IMPACT OF A UNIFORM ACCESS IMPROVEMENT
    SKABURSKIS, A
    [J]. ENVIRONMENT AND PLANNING A, 1990, 22 (05) : 689 - 693
  • [50] Hand Ischemia Associated With Dialysis Vascular Access: An Individualized Access Flow-based Approach to Therapy
    Beathard, Gerald A.
    Spergel, Lawrence M.
    [J]. SEMINARS IN DIALYSIS, 2013, 26 (03) : 287 - 314