Impact of a quality improvement programme based on vascular access flow monitoring on costs, access occlusion and access failure

被引:34
|
作者
Wijnen, Edwin
Planken, Nils
Keuter, Xavier
Kooman, Jeroen P.
Tordoir, Jan H. M.
de Haan, Michiel W.
Leunissen, Karel M. L.
van der Sande, Frank
机构
[1] Univ Hosp Maastricht, Dept Internal Med & Nephrol, NL-6202 AZ Maastricht, Netherlands
[2] Univ Hosp Maastricht, Dept Surg, Maastricht, Netherlands
[3] Univ Hosp Maastricht, Dept Radiol, Maastricht, Netherlands
关键词
D O I
10.1093/ndt/gfl424
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
Background. Vascular access thrombosis is a substantial source of morbidity in chronic haemodialysis patients. Periodical access flow measurements can predict the presence of vascular access stenosis and provide an opportunity for early intervention to prevent subsequent vascular access thrombosis. By this system of quality improvement, vascular access-related costs might be reduced. The aim of this study was to analyse the cost impact of a quality improvement programme based on periodic access flow measurements. Methods. The number and costs of vascular access interventions (summary of angiography, percutaneous transluminal angioplasty, catheter placement, hospitalization days and costs for surgery) in the period 2001-2003 (quality improvement period; QIP, 218.6 patient-years observed) were retrospectively compared with a reference period (RP, 1996-1998, 214.4 patient-years observed) during which no access flow was measured. All access flow measurements were done on a regular base and interventions were performed according to the Kidney Disease Outcome Quality Initiative. Results. Surgical thrombectomy procedures were significantly less during the QIP (0.25 +/- 0.57 events/patient-year) compared with RP (0.63 +/- 1.06 events/patient-year; P = 0.000), whereas access loss was not significantly different. During the QIP, 205 radiological interventions were performed (0.88 +/- 1.16 events/patient-year), and in the RP around 48 (0.33 +/- 0.65 events/patient-year; P = 0.000). Access-related costs tended to be lower during the QIP compared with the RP. The cost reduction appeared to be limited to patients with arteriovenous graft (AVG), in which access-related costs were significantly lower during the QIP (e2360.95 +/- 2838.17 patient-year) compared with the RP (e4003.96 +/- 3810.92 patient-year; P = 0.012), but not in patients with arteriovenous fistula (AVF). Conclusion. A quality improvement programme based on periodical access flow measurement reduced the number of acute vascular access failures due to thrombotic events and also significantly reduced health care costs in patients with AVG, but not in patients with AVF. The quality improvement programme had no effect on access survival.
引用
收藏
页码:3514 / 3519
页数:6
相关论文
共 50 条
  • [1] Vascular access blood flow monitoring reduces access morbidity and costs
    McCarley, P
    Wingard, RL
    Shyr, Y
    Pettus, W
    Hakim, RM
    Ikizler, TA
    [J]. KIDNEY INTERNATIONAL, 2001, 60 (03) : 1164 - 1172
  • [2] Utility and limitations of access blood flow monitoring for vascular access failure.
    von Albertini, B
    Berger, J
    Marchand, C
    Wauters, JP
    Pereira, O
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2002, 13 : 236A - 236A
  • [3] Implementation of a vascular access quality programme improves vascular access care
    van Loon, M.
    van der Mark, W.
    Beukers, N.
    de Bruin, C.
    Blankestijn, P. J.
    Huisman, R. M.
    Zijlstra, J. J.
    van der Sande, F. M.
    Tordoir, J. H. M.
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 2007, 22 (06) : 1628 - 1632
  • [4] Monitoring vascular access flow
    Lindsay, RM
    Leypoldt, JK
    [J]. ADVANCES IN RENAL REPLACEMENT THERAPY, 1999, 6 (03): : 273 - 277
  • [5] Use of vascular access blood flow to evaluate vascular access
    Paulson, WD
    Ram, SJ
    Work, J
    [J]. AMERICAN JOURNAL OF KIDNEY DISEASES, 2001, 38 (04) : 916 - 916
  • [6] Quality assurance and continuous quality improvement in the management of vascular access
    Bosch, JP
    Walters, BAJ
    [J]. HEMODIALYSIS TECHNOLOGY, 2002, 137 : 60 - 69
  • [7] A FRAMEWORK FOR TARGETING QUALITY IMPROVEMENT IN HAEMODIALYSIS VASCULAR ACCESS
    Stoumpos, Sokratis
    Murray, Eleanor C.
    Kingsmore, David B.
    Kasthuri, Ram
    Thomson, Peter C.
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 2016, 31 : 42 - 43
  • [8] A dedicated quality improvement programme can increase access to paediatric minimal access surgery in South Africa
    Mangray, H.
    Madziba, S.
    Ngobese, A.
    Smith, M. T. D.
    Clarke, D. L.
    [J]. SOUTH AFRICAN JOURNAL OF SURGERY, 2024, 62 (01) : 37 - 42
  • [9] Diagnostic methods for vascular access: Access flow measurements
    Leypoldt, JK
    [J]. HEMODIALYSIS TECHNOLOGY, 2002, 137 : 31 - 37
  • [10] Improvement in hemodialysis vascular access outcomes in a dedicated access center
    Arnold, WP
    [J]. SEMINARS IN DIALYSIS, 2000, 13 (06) : 359 - 363