Changes in the natural abundance of 13CO2/12CO2 in breath due to lipopolysacchride-induced acute phase response

被引:19
|
作者
Butz, Daniel E. [1 ]
Cook, Mark E. [2 ]
Eghbalnia, Hamid R. [3 ]
Assadi-Porter, Fariba [4 ,5 ]
Porter, Warren P. [1 ]
机构
[1] Univ Wisconsin, Dept Zool, Madison, WI 53706 USA
[2] Univ Wisconsin, Dept Anim Sci, Madison, WI 53706 USA
[3] Univ Cincinnati, Dept Mol & Cellular Physiol, Cincinnati, OH 45221 USA
[4] Univ Wisconsin, Dept Biochem, Madison, WI 53706 USA
[5] Univ Wisconsin, NMR Facil Madison, Madison, WI 53706 USA
关键词
STABLE CARBON ISOTOPES; NECROSIS; C-13/C-12; ENDOTOXIN; C-13; FRACTIONATION; TURNOVER; NITROGEN; PLASMA; RATIOS;
D O I
10.1002/rcm.4310
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The natural abundance of carbon-13 in blood proteins increases during the cachectic state and may be a biomarker for disease status. We hypothesized a corresponding drop in the relative abundance of C-13 in breath CO2. Using the lipopolysacchride (LPS)-induced endotoxemia model of the acute cachectic state, we demonstrated that the acute phase response causes shifts in the stable isotopes of carbon in exhaled CO2 ((CO2)-C-13/(CO2)-C-12 delta value) shortly after administration of LPS while glucocorticoid treatment does not. Mice were injected with LPS and stable isotopes of blood amino acids and carbon in exhaled CO2 were monitored. An increase in the relative isotopic mass of serum alanine, proline and threonine was observed at 3 h after LPS injection. Breath delta values began dropping immediately after administration of LPS, and were 4-5 delta values lower than those of the control animals by 2.5 h after injection. A corresponding drop in delta value was not observed with dexamethasone treatment. Thus protein synthesis during the acute phase response probably caused the fractionation of stable isotopes observed in the plasma amino acids and in exhaled breath (CO2)-C-13 delta values. The exhaled breath (CO2)-C-13 delta value may be a valuable real-time biomarker of cachexia associated with an acute phase response due to endotoxemia. Copyright (c) 2009 John Wiley & Sons, Ltd.
引用
收藏
页码:3729 / 3735
页数:7
相关论文
共 50 条
  • [31] Carbon Isotope Fractionation during the Formation of CO2 Hydrate and Equilibrium Pressures of 12CO2 and 13CO2 Hydrates
    Kimura, Hiromi
    Fuseya, Go
    Takeya, Satoshi
    Hachikubo, Akihiro
    MOLECULES, 2021, 26 (14):
  • [32] Quantitative Analysis of 12CO2, 13CO2, 12CH4 and 13CH4 Gases by Raman Spectroscopy
    Vitkin, V. V.
    Chubchenko, I. K.
    Popov, E. E.
    Polishchuk, A. V.
    Loiko, P. A.
    INTERNATIONAL CONFERENCE LASER OPTICS 2020 (ICLO 2020), 2020,
  • [33] 13CO2/12CO2 exchange fluxes in a clamp-on leaf cuvette: disentangling artefacts and flux components
    Gong, Xiao Ying
    Schaeufele, Rudi
    Feneis, Wolfgang
    Schnyder, Hans
    PLANT CELL AND ENVIRONMENT, 2015, 38 (11): : 2417 - 2432
  • [34] Isotopologue dependence of the CO2-air broadening and shifting coefficients: Experimental evidence and comparison with theory for 13CO2 and 12CO2
    Mondelain, Didier
    Campargue, Alain
    Gamache, Robert R.
    Hartmann, Jean-Michel
    Gibert, Fabien
    Wagner, Georg
    Birk, Manfred
    Roeske, Christian
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2025, 333
  • [35] Intercomparison of two cavity ring-down spectroscopy analyzers for atmospheric 13CO2/12CO2 measurement
    Pang, Jiaping
    Wen, Xuefa
    Sun, Xiaomin
    Huang, Kuan
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2016, 9 (08) : 3879 - 3891
  • [36] Disentangling CO2 fluxes:: direct measurements of mesocosm-scale natural abundance 13CO2/12CO2 gas exchange, 13C discrimination, and labelling of CO2 exchange flux components in controlled environments
    Schnyder, H
    Schäufele, R
    Lötscher, M
    Gebbing, T
    PLANT CELL AND ENVIRONMENT, 2003, 26 (11): : 1863 - 1874
  • [37] Application of adaptive filters to improve online detection sensitivity of 13CO2 in a mixture with 12CO2 in expiratory air
    Kireev, S. V.
    Kondrashov, A. A.
    Shnyrev, S. L.
    LASER PHYSICS LETTERS, 2019, 16 (07)
  • [38] An off-axis cavity-enhanced absorption spectrometer at 1605 nm for the 12CO2/13CO2 measurement
    Kasyutich, V. L.
    Martin, P. A.
    Holdsworth, R. J.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2006, 85 (2-3): : 413 - 420
  • [39] Diode laser absorption spectrometry for 13CO2/12CO2 isotope ratio analysis: Investigation on precision and accuracy levels
    A. Castrillo
    G. Casa
    E. Kerstel
    L. Gianfrani
    Applied Physics B, 2005, 81 : 863 - 869
  • [40] An off-axis cavity-enhanced absorption spectrometer at 1605 nm for the 12CO2/13CO2 measurement
    V.L. Kasyutich
    P.A. Martin
    R.J. Holdsworth
    Applied Physics B, 2006, 85 : 413 - 420