Monte Carlo simulation of the neutron spectral fluence and dose equivalent for use in shielding a proton therapy vault

被引:16
|
作者
Zheng, Yuanshui [1 ]
Newhauser, Wayne [2 ]
Klein, Eric [1 ]
Low, Daniel [1 ]
机构
[1] Washington Univ, Sch Med, Dept Radiat Oncol, St Louis, MO 63110 USA
[2] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Unit 94, Houston, TX 77030 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2009年 / 54卷 / 22期
关键词
INTRANUCLEAR-CASCADE CALCULATION; STRAY RADIATION; SECONDARY NEUTRON; RADIOTHERAPY; EXPOSURES; FACILITY; DESIGN; CANCER; FETUS;
D O I
10.1088/0031-9155/54/22/013
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Neutron production is of principal concern when designing proton therapy vault shielding. Conventionally, neutron calculations are based on analytical methods, which do not accurately consider beam shaping components and nozzle shielding. The goal of this study was to calculate, using Monte Carlo modeling, the neutron spectral fluence and neutron dose equivalent generated by a realistic proton therapy nozzle and evaluate how these data could be used in shielding calculations. We modeled a contemporary passive scattering proton therapy nozzle in detail with the MCNPX simulation code. The neutron spectral fluence and dose equivalent at various locations in the treatment room were calculated and compared to those obtained from a thick iron target bombarded by parallel proton beams, the simplified geometry on which analytical methods are based. The neutron spectral fluence distributions were similar for both methods, with deeply penetrating high-energy neutrons (E > 10 MeV) being most prevalent along the beam central axis, and low-energy neutrons predominating the neutron spectral fluence in the lateral region. However, unlike the inverse square falloff used in conventional analytical methods, this study shows that the neutron dose equivalent per therapeutic dose in the treatment room decreased with distance approximately following a power law, with an exponent of about -1.63 in the lateral region and -1.73 in the downstream region. Based on the simulated data according to the detailed nozzle modeling, we developed an empirical equation to estimate the neutron dose equivalent at any location and distance in the treatment vault, e. g. for cases in which detailed Monte Carlo modeling is not feasible. We applied the simulated neutron spectral fluence and dose equivalent to a shielding calculation as an example.
引用
收藏
页码:6943 / 6957
页数:15
相关论文
共 50 条
  • [41] The influence of nuclear models and Monte Carlo radiation transport codes on stray neutron dose estimations in proton therapy
    De Saint-Hubert, M.
    Farah, J.
    Klodowska, M.
    Romero-Exposito, M. T.
    Tyminska, K.
    Mares, V
    Olko, P.
    Stolarczyk, L.
    Trinkl, S.
    [J]. RADIATION MEASUREMENTS, 2022, 150
  • [42] High Energy Neutron Shielding for High Yield Proton PCB Exposure: A Monte Carlo Study
    Zimmerman, S.
    Moyer, D.
    Wolf, E.
    Ionascu, D.
    Lamba, M.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E341 - E341
  • [43] The Monte Carlo simulation of neutron shielding performance of boron carbide reinforced with aluminum composites
    Dai Chun-Juan
    Liu Xi-Qin
    Liu Zi-Li
    Liu Bo-Lu
    [J]. ACTA PHYSICA SINICA, 2013, 62 (15)
  • [44] A Monte Carlo simulation model to determine the effective concrete materials for fast neutron shielding
    Paul, Mannu Bardhan
    Ankan, Anirban Dutta
    Deb, Himadri
    Ahasan, M. Monjur
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2023, 202
  • [45] Monte carlo simulation of a radiation shielding carrier for proton-beam-irradiated sample
    Ra, Se-Jin
    Jung, Myung-Hwan
    Kim, Kye-Ryung
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2013, 63 (07) : 1407 - 1413
  • [46] Stray Neutron Radiation Exposures From Proton Therapy: Physics-Based Analytical Models of Neutron Spectral Fluence, Kerma and Absorbed Dose
    Shrestha, S.
    Newhauser, W.
    Donahue, W.
    Perez-Andujar, A.
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : E857 - E858
  • [47] Monte Carlo fluence simulation for prospective evaluation of interstitial photodynamic therapy treatment plans
    Cassidy, Jeffrey
    Betz, Vaughn
    Lilge, Lothar
    [J]. OPTICAL METHODS FOR TUMOR TREATMENT AND DETECTION: MECHANISMS AND TECHNIQUES IN PHOTODYNAMIC THERAPY XXIV, 2015, 9308
  • [48] Stray neutron radiation exposures from proton therapy: physics-based analytical models of neutron spectral fluence, kerma and absorbed dose
    Shrestha, Suman
    Newhauser, Wayne D.
    Donahue, William P.
    Perez-Andujar, Angelica
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (12):
  • [49] Monte Carlo Computation of the Effective Dose in Scanning Beam Proton Therapy
    Mirkovic, D.
    Titt, U.
    Sawakuchi, G.
    Zhang, X.
    Li, Y.
    Mohan, R.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)
  • [50] Monte carlo simulation of a radiation shielding carrier for proton-beam-irradiated sample
    Se-Jin Ra
    Myung-Hwan Jung
    Kye-Ryung Kim
    [J]. Journal of the Korean Physical Society, 2013, 63 : 1407 - 1413