Experimental comparison of different dead-time correction techniques in single-channel counting experiments

被引:16
|
作者
Michotte, C. [1 ]
Nonis, M. [1 ]
机构
[1] Bur Int Poids & Mesures, F-92312 Sevres, France
关键词
(Non-)extendable dead time; Dead times in series; Dead-time transmission formulae; Live-time correction; Analogue pulse width; SYSTEMS;
D O I
10.1016/j.nima.2009.06.010
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
For single-channel counting, the dead-time correction method using transmission formulae was compared experimentally with the live-time technique. Agreement is within 4 x 10(-4) for count rates up to 10(4) s(-1) when the formulae for dead times in series are used and the dead-time value related to the analogue pulse width is adjusted for the BIPM modules. At higher count rates, a bias of 2 x 10(-3) is observed. Two different live-time modules were compared and it was demonstrated that the live-time correction is also sensitive to the analogue pulse width and to the duration or rise time of the clock pulses. When these effects are taken into account, the two modules differ by only 5 x 10(-4). (c) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:163 / 168
页数:6
相关论文
共 50 条
  • [31] SINGLE-CHANNEL AND 2-CHANNEL MODES OF TIME-TO-BACKGROUND OPTIMIZATION OF LOW-LEVEL COUNTING
    SARO, S
    NUCLEAR INSTRUMENTS & METHODS, 1975, 128 (01): : 121 - 124
  • [32] Channel likelihood correction for photon-counting array receivers in the presence of dead time and jitters
    Xiang, Jingsong
    Jia, Yuanming
    Deng, Chenhui
    Huang, Sheng
    Li, Changping
    Chen, Xueli
    Zhang, Pei
    Wu, Yimiao
    OPTICS EXPRESS, 2018, 26 (03): : 2848 - 2856
  • [33] INFLUENCE OF THE HALF-LIFE OF A METASTABLE STATE ON THE DEAD-TIME CORRECTION FOR NONEXTENDING DEAD TIMES IN SINGLE DETECTOR SYSTEMS.
    Funck, E.
    Nuclear instruments and methods in physics research, 1987, A254 (03): : 604 - 610
  • [34] Evaluate Different Machine Learning Techniques for Classifying Sleep Stages on Single-Channel EEG
    Qureshi, Shahnawaz
    Vanichayobon, Sirirut
    PROCEEDINGS OF 2017 14TH INTERNATIONAL JOINT CONFERENCE ON COMPUTER SCIENCE AND SOFTWARE ENGINEERING (JCSSE), 2017,
  • [35] PERFORMANCE COMPARISON OF REAL-TIME SINGLE-CHANNEL SPEECH DEREVERBERATION ALGORITHMS
    Xiong, Feifei
    Meyer, Bernd T.
    Cauchi, Benjamin
    Jukic, Ante
    Doclo, Simon
    Goetze, Stefan
    2017 HANDS-FREE SPEECH COMMUNICATIONS AND MICROPHONE ARRAYS (HSCMA 2017), 2017, : 126 - 130
  • [36] Probing the "Dead-Time" in NMR by Combining Single Pulse and Solid Echo Experiments Followed by a Global Model Fit Analysis
    Hansen, Eddy Walther
    APPLIED MAGNETIC RESONANCE, 2024, 55 (04) : 477 - 496
  • [37] Probing the “Dead-Time” in NMR by Combining Single Pulse and Solid Echo Experiments Followed by a Global Model Fit Analysis
    Eddy Walther Hansen
    Applied Magnetic Resonance, 2024, 55 : 477 - 496
  • [38] Experimental evaluation of the extended Dytlewski-style dead time correction formalism for neutron multiplicity counting
    Lockhart, M.
    Henzlova, D.
    Croft, S.
    Cutler, T.
    Favalli, A.
    McGahee, Ch.
    Parker, R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 879 : 69 - 76
  • [39] THE MALONYL GRAMICIDIN CHANNEL - NMR-DERIVED RATE CONSTANTS AND COMPARISON OF CALCULATED AND EXPERIMENTAL SINGLE-CHANNEL CURRENTS
    URRY, DW
    VENKATACHALAM, CM
    SPISNI, A
    BRADLEY, RJ
    TRAPANE, TL
    PRASAD, KU
    JOURNAL OF MEMBRANE BIOLOGY, 1980, 55 (01): : 29 - 51
  • [40] COMPARISON OF SEVERAL METHODS PROPOSED FOR CORRECTION OF DEAD-TIME LOSSES IN GAMMA-RAY SPECTROMETRY OF VERY SHORT-LIVED NUCLIDES
    WIERNIK, M