The totally implantable hearing aid

被引:0
|
作者
Zenner, HP [1 ]
机构
[1] Univ Tubingen, Klin Hals Nasen & Ohrenheilkunde, D-72076 Tubingen, Germany
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Since several years, implantable hearing aids are available to overcome shortcomings of conventional hearing aids. Hearing aids have fundamental disadvantages: (1) stigmatization of the patient; (2) the sound is often found to be unsatisfactory due to the limited frequency range and undesired distortion; (3) in many patients, the ear canal fitting device generally necessary leads to an occlusion effect; (4) acoustic feedback when amplification is high. Conventional hearing aids transmit sound into the ear canal via a small microphone. Sound has the disadvantage of requiring high output sound pressure levels for its transmission. This along with the necessary miniaturization of the loudspeaker as well as the resonances and reflections in the closed ear canal contribute to the disadvantages mentioned. Implantable hearing aids do not make sound signals but micromechanical vibrations. An implantable hearing aid has an electromechanical transducer instead of the loudspeaker of a conventional hearing aid. The hearing signal does not leave the transducer as sound but as a mechanical vibration which is directly coupled to the auditory system bypassing the air. The totally implantable hearing aid TICA(R) is either coupled to the ossicular chain or the perilymph of the inner ear.
引用
收藏
页码:251 / +
页数:6
相关论文
共 50 条
  • [31] Design of a Totally Implantable Artificial Cochlea Mimicking the Human Hearing Mechanism
    Kim, W. D.
    Lee, J. H.
    Choi, H. S.
    Hur, S.
    Park, J. S.
    EKC 2010: PROCEEDINGS OF THE EU-KOREA CONFERENCE ON SCIENCE AND TECHNOLOGY, 2011, 138 : 67 - 75
  • [32] Profound High-Frequency Sensorineural Hearing Loss Treatment With a Totally Implantable Hearing System
    Shohet, Jack A.
    Kraus, Eric M.
    Catalano, Peter J.
    OTOLOGY & NEUROTOLOGY, 2011, 32 (09) : 1428 - 1431
  • [33] THE EFFICACY OF A PIEZOELECTRIC CERAMIC VIBRATOR FOR THE IMPLANTABLE HEARING-AID
    KODERA, K
    YAMANE, H
    SUZUKI, K
    ARAKI, H
    ARTIFICIAL ORGANS, 1981, 5 (03) : 339 - 339
  • [34] In vivo experiments in the cat with an implantable piezoelectric hearing aid transducer
    Plinkert, PK
    Baumann, JW
    Lenarz, T
    Keiner, S
    Leysieffer, H
    Zenner, HP
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2000, 257 (06) : 304 - 313
  • [35] THE ROUND WINDOW ELECTROMAGNETIC IMPLANTABLE HEARING-AID APPROACH
    SPINDEL, JH
    LAMBERT, PR
    RUTH, RA
    OTOLARYNGOLOGIC CLINICS OF NORTH AMERICA, 1995, 28 (01) : 189 - 205
  • [36] Animal experiments with a piezoelectrical implantable hearing aid transducer in the cat
    Plinkert, PK
    Baumann, JW
    Lenarz, T
    Keiner, S
    Leysieffer, H
    Zenner, HP
    HNO, 1997, 45 (10) : 828 - 839
  • [37] In vitro model for intraoperative adjustments in an implantable hearing aid (MET)
    Jorge, JR
    Pfister, M
    Zenner, HP
    Zalaman, IM
    Maassen, MM
    LARYNGOSCOPE, 2006, 116 (03): : 473 - 481
  • [38] IMPLANTABLE HEARING-AID IN 14 PATIENTS WITH MIXED DEAFNESS
    YANAGIHARA, N
    GYO, K
    SATO, H
    YAMANAKA, E
    SAIKI, T
    ACTA OTO-LARYNGOLOGICA, 1988, : 90 - 94
  • [39] In vivo experiments in the cat with an implantable piezoelectric hearing aid transducer
    P. K. Plinkert
    Joachim W. Baumann
    Thomas Lenarz
    Sabine Keiner
    Hans Leysieffer
    Hans Peter Zenner
    European Archives of Oto-Rhino-Laryngology, 2000, 257 : 304 - 313
  • [40] An implantable hearing aid for sensorineural hearing loss: first implantation of microphone and transducer in patients
    Zenner, HP
    Maassen, MM
    Lehner, RL
    Baumann, JW
    Leysieffer, H
    HNO, 1997, 45 (10) : 872 - 880