Examination of Solar Simulators Used for the Determination of Sunscreen UVA Efficacy

被引:4
|
作者
Sayre, Robert M. [1 ,2 ]
Dowdy, John C. [1 ]
机构
[1] Rapid Precis Testing Lab, Cordova, TN USA
[2] Univ Tennessee, Ctr Hlth Sci, Dept Med, Div Dermatol, Memphis, TN 38163 USA
关键词
PIGMENT DARKENING PPD; RADIATION; SPECTRUM;
D O I
10.1111/j.1751-1097.2009.00633.x
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The U.S. FDA recently proposed both in vivo and in vitro UVA efficacy tests for sunscreen products with the lower result used to establish the sunscreen's labeled UVA protection claim. The FDA stated their rationale for dual tests was concern that the in vivo test method overemphasizes UVA-2 (320-340 nm) photoprotection. We attribute FDA's observation to the relative lack, compared to sunlight, of UVA-1 (340-400 nm) radiation in the current JCIA UVA solar simulator specification, allowing the method to generate higher UVA protection factors than sunscreens will provide in sunlight. Our work is based upon comparisons of Air Mass 1.0 sunlight to variously filtered UVA solar simulators. Sources near the JCIA UVA-2/UVA limits (8-20%) had a goodness of fit to solar UVA of only 67-79%. We propose that instead of using ratios of UVA-2 to UVA the standard should be a goodness of fit to the UVA region of an Air Mass 1 solar reference spectrum. As the spectral distribution of solar UVA varies much less than UVB, sunlight of reasonable zenith angles of < 60 degrees will have similar spectral shapes and approximate risk spectrum. Goodness of fit to this spectrum will produce UVA protection values predictive to those actually achieved in sunlight of different zenith angles.
引用
收藏
页码:162 / 167
页数:6
相关论文
共 50 条
  • [41] CLINICAL-EVALUATION OF THE EFFICACY OF A ELECTRONIC METHOD METHOD USED AT ROOT-CANAL LENGTH DETERMINATION
    NISHIYAMA, CK
    [J]. JOURNAL OF DENTAL RESEARCH, 1995, 74 (03) : 798 - 798
  • [42] Determination of the residual efficacy of carbamate and organophosphate insecticides used for indoor residual spraying for malaria control in Ethiopia
    Yewhalaw, Delenasaw
    Balkew, Meshesha
    Shililu, Josephat
    Suleman, Sultan
    Getachew, Alemayehu
    Ashenbo, Gedeon
    Chibsa, Sheleme
    Dissanayake, Gunawardena
    George, Kristen
    Dengela, Dereje
    Ye-Ebiyo, Yemane
    Irish, Seth R.
    [J]. MALARIA JOURNAL, 2017, 16
  • [43] Determination of the residual efficacy of carbamate and organophosphate insecticides used for indoor residual spraying for malaria control in Ethiopia
    Delenasaw Yewhalaw
    Meshesha Balkew
    Josephat Shililu
    Sultan Suleman
    Alemayehu Getachew
    Gedeon Ashenbo
    Sheleme Chibsa
    Gunawardena Dissanayake
    Kristen George
    Dereje Dengela
    Yemane Ye-Ebiyo
    Seth R. Irish
    [J]. Malaria Journal, 16
  • [44] Evaluation of the efficacy of a sunscreen containing ultra-long UVA1 and other UVR broad-spectrum filters on skin barrier protection and melanin content reduction in Chinese adults: A single-center study
    Zhang, Xianghua
    Tao, Han
    Zhang, Zhongxing
    Wang, Wenna
    Steel, Andrew
    Fang, Xiaofeng
    He, Xiaofeng
    [J]. HEALTH SCIENCE REPORTS, 2024, 7 (02)
  • [45] Determination of efficacy of physical examination in the diagnosis diaphragmatic injuries due to stab wound to lower thoracic area confirmed with thoracoscopy
    Khazaei, Alireza
    Dahmardehei, Mostafa
    Narouie, Behzad
    Toosi, Arash Beiraghi
    [J]. LIFE SCIENCE JOURNAL-ACTA ZHENGZHOU UNIVERSITY OVERSEAS EDITION, 2012, 9 (03): : 1527 - 1531
  • [46] LIQUID-CHROMATOGRAPHIC DETERMINATION OF EFFICACY OF INCORPORATION OF TRIMETHOPRIM AND SULFAMETHOXAZOLE IN BRINE SHRIMP (ARTEMIA SPP) USED FOR PROPHYLACTIC CHEMOTHERAPY OF FISH
    NELIS, HJ
    LEGER, F
    SORGELOOS, P
    DELEENHEER, AP
    [J]. ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 1991, 35 (12) : 2486 - 2489
  • [47] Practical method for determination of air kerma by use of an ionization chamber toward construction of a secondary X-ray field to be used in clinical examination rooms
    Maehata I.
    Hayashi H.
    Kimoto N.
    Takegami K.
    Okino H.
    Kanazawa Y.
    Tominaga M.
    [J]. Radiological Physics and Technology, 2016, 9 (2) : 193 - 201
  • [48] Application of ICP-OES to the determination of CuIn1-xGaxSe2 thin films used as absorber materials in solar cell devices
    Fernández-Martínez, R
    Caballero, R
    Guillén, C
    Gutiérrez, MT
    Rucandio, MI
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 382 (02) : 466 - 470
  • [49] Results of the Self-efficacy Stimulative Scale used for e-learning by Physical Therapy Vocational School Students-Examination by Exploratory Factor Analysis-
    Onuki, Mutsumi
    Maruyama, Hitoshi
    [J]. JOURNAL OF PHYSICAL THERAPY SCIENCE, 2011, 23 (01) : 81 - 84
  • [50] Application of ICP-OES to the determination of CuIn1−xGaxSe2 thin films used as absorber materials in solar cell devices
    Rodolfo Fernández-Martínez
    Raquel Caballero
    Cecilia Guillén
    María Teresa Gutiérrez
    María Isabel Rucandio
    [J]. Analytical and Bioanalytical Chemistry, 2005, 382 : 466 - 470