Figulla ASD Occluder versus Amplatzer Septal Occluder: A Comparative Study on Validation of a Novel Device for Percutaneous Closure of Atrial Septal Defects

被引:44
|
作者
Pac, Aysenur [1 ]
Polat, Tugcin Bora [1 ]
Cetin, Ilker [1 ]
Oflaz, Mehmet Burhan [1 ]
Balli, Sevket [1 ]
机构
[1] TurkiyeYuksek Ihtisas Educ & Res Hosp, Clin Pediat Cardiol, TR-06100 Ankara, Turkey
关键词
TRANSCATHETER CLOSURE; NONOPERATIVE CLOSURE; OCCLUSION; COMPLICATIONS; EXPERIENCE;
D O I
10.1111/j.1540-8183.2009.00497.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Interventions: Between December 2005 and February 2009, 75 patients diagnosed with secundum atrial septal defects underwent transcatheter closure. The FSO device was used in 33 patients, and the ASO was used in 42. Results: Patient characteristics, stretch size of the defect, device left disc size, procedure, and fluoroscopy time were similar between the groups. However, the difference between device waist size and stretched diameter of the defect was significantly higher, and device delivery sheath was significantly larger in FSO group and device left disc size was significantly lower in the FSO group. In all subjects, the residual shunt was small to trivial during follow-up and the reduction in prevalence of residual shunt with time was similar in both groups (P = 0.68). We found no differences in complication rate between the two devices; however, device embolization to the pulmonary bifurcation in one patient was recorded as major complication in FSO device group. Conclusions: Both devices are clinically safe and effective in ASD closure. FSO device has similar outcomes when compared to ASO device. Difficulties in selecting the correct device size in larger defects and larger venous sheath requirement need to be evaluated in further studies. (J Interven Cardiol 2009;22:489-495).
引用
收藏
页码:489 / 495
页数:7
相关论文
共 50 条
  • [31] Clinical results of percutaneous closure of large secundum atrial septal defects in children using the Amplatzer septal occluder
    Huang, Ta Cheng
    Hsieh, Kai-Sheng
    Lin, Chu-Chun
    Lee, Cheng-Liang
    HEART AND VESSELS, 2008, 23 (03) : 187 - 192
  • [32] Clinical results of percutaneous closure of large secundum atrial septal defects in children using the Amplatzer septal occluder
    Ta Cheng Huang
    Kai-Sheng Hsieh
    Chu-Chun Lin
    Cheng-Liang Lee
    Heart and Vessels, 2008, 23 : 187 - 192
  • [33] Reliability of transthoracic echocardiography in estimating the size of Amplatzer septal occluder and guiding percutaneous closure of atrial septal defects
    Li Gui-shuang
    Kong Guang-ming
    Ji Qiu-shang
    Li Ji-fu
    Chen Yu-guo
    You Bei-an
    Zhang Yun
    CHINESE MEDICAL JOURNAL, 2008, 121 (11) : 973 - 976
  • [34] Reliability of transthoracic echocardiography in estimating the size of Amplatzer septal occluder and guiding percutaneous closure of atrial septal defects
    LI GuishuangKONG GuangmingJI QiushangLI JifuCHEN YuguoYOU Beian and ZHANG Yun Key Laboratory of Cardiovascular Remodeling and Function ResearchChinese Ministry of Education and Chinese Ministry of Health Department of Emergency Medicine
    Department of Geriatrics Qilu HospitalShandong UniversityJinanShandong China
    中华医学杂志(英文版), 2008, (11) : 973 - 976
  • [35] Percutaneous closure of two atrial septal defects with individual septal occluder devices
    Ilkay, Erdogan
    Firat, Sakine
    Dagli, Necati
    Ozeke, Ozcan
    TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2010, 38 (01): : 41 - 43
  • [36] Displacement of Amplatzer septal occluder in a patient with atrial septal defects and an atrial septal aneurysm
    Oda, Takeshi
    Kato, Seiya
    Suda, Kenji
    CARDIOLOGY IN THE YOUNG, 2016, 26 (07) : 1430 - 1431
  • [37] Atrial septal defect closure with the Amplatzer-Septal-Occluder in adults
    Majunke, Nicolas
    Bialkowski, Jacek
    Wilson, Neil
    Skutnik, Malgorzata
    Baranowski, Jacek
    Kusa, Jacek
    Baranowski, Andreas
    Heinisch, Corinna
    Leetz, Michaela
    Fischer, Evelyn
    Taaffe, Margaret
    Reschke, Madlen
    Bayard, Yves
    Stermayer, Stefan
    Hein, Ralph
    Buschek, Franziska
    Billinger, Kai
    Trepels, Thomas
    Lang, Klaus
    Wunderlich, Nina
    Sievert, Horst
    AMERICAN JOURNAL OF CARDIOLOGY, 2006, 98 (8A): : 227M - 227M
  • [38] Percutaneous successful closure of dual atrial septal defect with two Amplatzer septal occluder devices
    Hamza Duygu
    Halit Acet
    Ugur Kocabas
    Zehra Ilke Akyildiz
    Cem Nazli
    Oktay Ergene
    Clinical Research in Cardiology, 2010, 99 : 329 - 331
  • [39] Percutaneous successful closure of dual atrial septal defect with two Amplatzer septal occluder devices
    Duygu, Hamza
    Acet, Halit
    Kocabas, Ugur
    Akyildiz, Zehra Ilke
    Nazli, Cem
    Ergene, Oktay
    CLINICAL RESEARCH IN CARDIOLOGY, 2010, 99 (05) : 329 - 331
  • [40] Amplatzer® septal occluder device for closure of aortic pseudoaneurysms
    Jolly, Neeraj
    Garg, Ravi Kumar
    Raman, Jaishankar
    Hijazi, Ziyad M.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2007, 70 (04) : 619 - 620