MicroED with the Falcon III direct electron detector

被引:36
|
作者
Hattne, Johan [1 ]
Martynowycz, Michael W. [1 ]
Penczek, Pawel A. [2 ]
Gonen, Tamir [1 ,3 ]
机构
[1] Univ Calif Los Angeles, David Geffen Sch Med, Dept Biol Chem, Howard Hughes Med Inst, Los Angeles, CA 90095 USA
[2] Univ Texas Houston, McGovern Med Sch, Dept Biochem & Mol Biol, Houston, TX 77030 USA
[3] Univ Calif Los Angeles, David Geffen Sch Med, Dept Physiol, Howard Hughes Med Inst, Los Angeles, CA 90095 USA
来源
IUCRJ | 2019年 / 6卷
关键词
microcrystal electron diffraction; MicroED; Falcon III; direct electron detectors; RADIATION-DAMAGE; DATA-COLLECTION; DIFFRACTION; CRYSTALLOGRAPHY; CRYSTALS;
D O I
10.1107/S2052252519010583
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Microcrystal electron diffraction (MicroED) combines crystallography and electron cryo-microscopy (cryo-EM) into a method that is applicable to high-resolution structure determination. In MicroED, nanosized crystals, which are often intractable using other techniques, are probed by high-energy electrons in a transmission electron microscope. Diffraction data are recorded by a camera in movie mode: the nanocrystal is continuously rotated in the beam, thus creating a sequence of frames that constitute a movie with respect to the rotation angle. Until now, diffraction-optimized cameras have mostly been used for MicroED. Here, the use of a direct electron detector that was designed for imaging is reported. It is demonstrated that data can be collected more rapidly using the Falcon III for MicroED and with markedly lower exposure than has previously been reported. The Falcon III was operated at 40 frames per second and complete data sets reaching atomic resolution were recorded in minutes. The resulting density maps to 2.1 angstrom resolution of the serine protease proteinase K showed no visible signs of radiation damage. It is thus demonstrated that dedicated diffraction-optimized detectors are not required for MicroED, as shown by the fact that the very same cameras that are used for imaging applications in electron microscopy, such as single-particle cryo-EM, can also be used effectively for diffraction measurements.
引用
收藏
页码:921 / 926
页数:6
相关论文
共 50 条
  • [41] A simple, static and stage mounted direct electron detector based electron backscatter diffraction system
    Zhang, Tianbi
    Ben Britton, T.
    MICRON, 2024, 178
  • [42] MicroED: Three Dimensional Electron Crystallography of Protein Micro-Crystals
    Gonen, T.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2014, 70 : C1063 - C1063
  • [43] Microcrystal Electron Diffraction (MicroED) for Small-Molecule Structure Determination
    Kunde, Tom
    Schmidt, Bernd M.
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2019, 58 (03) : 666 - 668
  • [44] Publisher Correction: The cryo-EM method microcrystal electron diffraction (MicroED)
    Brent L. Nannenga
    Tamir Gonen
    Nature Methods, 2021, 18 (5) : 574 - 574
  • [45] The 4D Camera: An 87 kHz Direct Electron Detector for Scanning/Transmission Electron Microscopy
    Ercius, Peter
    Johnson, Ian J.
    Pelz, Philipp
    Savitzky, Benjamin H.
    Hughes, Lauren
    Brown, Hamish G.
    Zeltmann, Steven E.
    Hsu, Shang-Lin
    Pedroso, Cassio C. S.
    Cohen, Bruce E.
    Ramesh, Ramamoorthy
    Paul, David
    Joseph, John M.
    Stezelberger, Thorsten
    Czarnik, Cory
    Lent, Matthew
    Fong, Erin
    Ciston, Jim
    Scott, Mary C.
    Ophus, Colin
    Minor, Andrew M.
    Denes, Peter
    MICROSCOPY AND MICROANALYSIS, 2024, 30 (05) : 903 - 912
  • [46] Direct single electron detection with a CMOS detector for electron microscopy (vol 546, pg 170, 2005)
    Faruqi, A. R.
    Henderson, R.
    Pryddetch, M.
    Allport, P.
    Evans, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 566 (02): : 770 - 770
  • [47] Performance of a silicon-on-insulator direct electron detector in a low-voltage transmission electron microscope
    Ishida, Takafumi
    Shinozaki, Akira
    Kuwahara, Makoto
    Miyoshi, Toshinobu
    Saitoh, Koh
    Arai, Yasuo
    MICROSCOPY, 2021, 70 (03) : 321 - 325
  • [48] Experimental observation of the improvement in MTF from backthinning a CMOS direct electron detector
    McMullan, G.
    Faruqi, A. R.
    Henderson, R.
    Guerrini, N.
    Turchetta, R.
    Jacobs, A.
    van Hoften, G.
    ULTRAMICROSCOPY, 2009, 109 (09) : 1144 - 1147
  • [49] New Approaches to Direct Bandgap III-V Materials for LWIR Detector Applications
    Sarney, W. L.
    Svensson, S. P.
    Hier, H.
    Donetsky, D.
    Wang, D.
    Shterengas, L.
    Suchalkin, S.