MicroED with the Falcon III direct electron detector

被引:36
|
作者
Hattne, Johan [1 ]
Martynowycz, Michael W. [1 ]
Penczek, Pawel A. [2 ]
Gonen, Tamir [1 ,3 ]
机构
[1] Univ Calif Los Angeles, David Geffen Sch Med, Dept Biol Chem, Howard Hughes Med Inst, Los Angeles, CA 90095 USA
[2] Univ Texas Houston, McGovern Med Sch, Dept Biochem & Mol Biol, Houston, TX 77030 USA
[3] Univ Calif Los Angeles, David Geffen Sch Med, Dept Physiol, Howard Hughes Med Inst, Los Angeles, CA 90095 USA
来源
IUCRJ | 2019年 / 6卷
关键词
microcrystal electron diffraction; MicroED; Falcon III; direct electron detectors; RADIATION-DAMAGE; DATA-COLLECTION; DIFFRACTION; CRYSTALLOGRAPHY; CRYSTALS;
D O I
10.1107/S2052252519010583
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Microcrystal electron diffraction (MicroED) combines crystallography and electron cryo-microscopy (cryo-EM) into a method that is applicable to high-resolution structure determination. In MicroED, nanosized crystals, which are often intractable using other techniques, are probed by high-energy electrons in a transmission electron microscope. Diffraction data are recorded by a camera in movie mode: the nanocrystal is continuously rotated in the beam, thus creating a sequence of frames that constitute a movie with respect to the rotation angle. Until now, diffraction-optimized cameras have mostly been used for MicroED. Here, the use of a direct electron detector that was designed for imaging is reported. It is demonstrated that data can be collected more rapidly using the Falcon III for MicroED and with markedly lower exposure than has previously been reported. The Falcon III was operated at 40 frames per second and complete data sets reaching atomic resolution were recorded in minutes. The resulting density maps to 2.1 angstrom resolution of the serine protease proteinase K showed no visible signs of radiation damage. It is thus demonstrated that dedicated diffraction-optimized detectors are not required for MicroED, as shown by the fact that the very same cameras that are used for imaging applications in electron microscopy, such as single-particle cryo-EM, can also be used effectively for diffraction measurements.
引用
收藏
页码:921 / 926
页数:6
相关论文
共 50 条
  • [1] MicroED with a direct electron detector
    Hattne, Johan
    Martynowycz, Michael
    Clabbers, Max
    Gonen, Tamir
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2021, 77 : A258 - A258
  • [2] Electron counting with direct electron detectors in MicroED
    Hattne, Johan
    Clabbers, Max T. B.
    Martynowycz, Michael W.
    Gonen, Tamir
    STRUCTURE, 2023, 31 (12) : 1504 - 1509.e1
  • [3] Capabilities of the Falcon III detector for single-particle structure determination
    Song Boyuan
    Lenhart, Julian
    Flegler, Vanessa Judith
    Makbul, Cihan
    Rasmussen, Tim
    Boettcher, Bettina
    ULTRAMICROSCOPY, 2019, 203 : 145 - 154
  • [4] Calibration of the Falcon Solid-state Energetic Electron Detector (SEED)
    Cress, R.
    Maldonado, C. A.
    Coulter, M.
    Haak, K.
    Balthazor, R. L.
    Mcharg, M. G.
    Barton, D.
    Greene, K.
    Lindstrom, C. D.
    SPACE WEATHER-THE INTERNATIONAL JOURNAL OF RESEARCH AND APPLICATIONS, 2020, 18 (05):
  • [5] High-Resolution Structure Determination At 100kv Enabled by New Falcon-C Direct Electron Detector
    Koh, Adrian
    Yang, Wen
    Karia, Dimple
    Yu, Lingbo
    Lengyel, Jeffrey
    Kotecha, Abhay
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2023, 79 : A140 - A140
  • [6] Electron-counting MicroED data with the K2 and K3 direct electron detectors
    Clabbers, Max T. B.
    Martynowycz, Michael W.
    Hattne, Johan
    Nannenga, Brent L.
    Gonen, Tamir
    JOURNAL OF STRUCTURAL BIOLOGY, 2022, 214 (04)
  • [7] An Overview of Microcrystal Electron Diffraction (MicroED)
    Mu, Xuelang
    Gillman, Cody
    Nguyen, Chi
    Gonen, Tamir
    ANNUAL REVIEW OF BIOCHEMISTRY, VOL 90, 2021, 2021, 90 : 431 - 450
  • [8] Direct single electron detection with a CMOS detector for electron microscopy
    Faruqi, AR
    Henderson, R
    Pryddetch, M
    Allport, P
    Evans, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 546 (1-2): : 170 - 175
  • [9] Data collection and processing with a direct electron detector
    Hattne, Johan
    Martynowycz, Michael W.
    Gonen, Tamir
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2019, 75 : A388 - A388
  • [10] Hot-electron direct detector for radioastronomy
    Karasik, B.S.
    McGrath, W.R.
    LeDuc, H.G.
    Gershenson, M.E.
    Superconductor Science and Technology, 1999, 12 (11): : 745 - 747