High-resolution optical coherence tomography visualization of LASIK flap displacement

被引:15
|
作者
Salaroli, Camila Haydee Rosas
Li, Yan
Huang, David
机构
[1] Univ So Calif, Keck Sch Med, Dept Ophthalmol, Los Angeles, CA 90033 USA
[2] Univ So Calif, Doheny Eye Inst, Ctr Ophthalm Opt & Lasers, Los Angeles, CA USA
来源
关键词
IN-SITU KERATOMILEUSIS; PHOTOTHERAPEUTIC KERATECTOMY; CORNEAL STRIAE; MANAGEMENT;
D O I
10.1016/j.jcrs.2009.04.025
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Uneventful myopic laser in situ keratomileusis (LASIK) was performed in both eyes of a 33-year-old woman. Two weeks after LASIK, examination of the left eye revealed flap striae radiating inferonasally from the superior hinge. The flap was relifted and repositioned to remove the irregular astigmatism and reduce the striae. Before the flap was relifted, Fourier-domain optical coherence tomography (FD-OCT) showed the gap at the temporal flap, which had not been detected by biomicroscopy. After the flap was relifted, FD-OCT documented that the gap was closed. High-resolution FD-OCT was helpful in the visualization and management of flap displacement.
引用
收藏
页码:1640 / 1642
页数:3
相关论文
共 50 条
  • [42] High Resolution Optical Coherence Tomography
    Ge, Xin
    Chen, Shufen
    Chen, Si
    Liu, Linbo
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2021, 39 (12) : 3824 - 3835
  • [43] LASIK anatomy by optical coherence tomography
    Huang, D
    Seffo, F
    Eshbaugh, CG
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S689 - S689
  • [44] Optical design of a dynamic focus catheter for high-resolution endoscopic optical coherence tomography
    Meemon, Panomsak
    Lee, Kye-Sung
    Murali, Supraja
    Rolland, Jannick
    APPLIED OPTICS, 2008, 47 (13) : 2452 - 2457
  • [45] Reproducibility of high-resolution optical coherence tomography measurements of the nerve fibre layer with the new Heidelberg Spectralis optical coherence tomography
    Serbecic, N.
    Beutelspacher, S. C.
    Aboul-Enein, F. C.
    Kircher, K.
    Reitner, A.
    Schmidt-Erfurth, U.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2011, 95 (06) : 804 - 810
  • [46] Hyperreflective sign in resolved cotton wool spots using high-resolution optical coherence tomography and optical coherence tomography ophthalmoscopy
    Kozak, Igor
    Bartsch, Dirk-Uwe
    Cheng, Lingyun
    Freeman, William R.
    OPHTHALMOLOGY, 2007, 114 (03) : 537 - 543
  • [47] High-Speed High-Resolution Optical Coherence Tomography at 800 and 1060 nm
    Povazay, B.
    Hofer, B.
    Hermann, B.
    Torti, C.
    Kajic, V.
    Unterhuber, A.
    Drexler, W.
    1ST CANTERBURY WORKSHOP ON OPTICAL COHERENCE TOMOGRAPHY AND ADAPTIVE OPTICS, 2008, 7139
  • [48] Microarchitecture of the Vitreous Body: A High-Resolution Optical Coherence Tomography Study Reply
    Uji, Akihito
    Yoshimura, Nagahisa
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2016, 170 : 244 - 244
  • [49] High-resolution endoscopic imaging of the GI tract using optical coherence tomography
    Sivak, MV
    Kobayashi, K
    Izatt, JA
    Rollins, AM
    Ung-runyawee, R
    Chak, A
    Wong, RCK
    Isenberg, GA
    Willis, J
    GASTROINTESTINAL ENDOSCOPY, 2000, 51 (04) : 474 - 479
  • [50] Controls of spectral shape and dispersion mismatch for high-resolution optical coherence tomography
    Hsu, IJ
    Sun, CW
    Lu, CW
    Yang, CC
    Chiang, CP
    Lin, CW
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE VII, 2003, 4956 : 115 - 119