Comparative evaluation of the ARCHITECT Toxo IgG, IgM, and IgG Avidity assays for anti-Toxoplasma antibodies detection in pregnant women sera

被引:44
|
作者
Gay-Andrieu, Francoise [1 ,2 ]
Fricker-Hidalgo, Helene [3 ]
Sickinger, Eva [4 ]
Espern, Anne [1 ,2 ]
Brenier-Pinchart, Marie-Pierre [3 ,5 ]
Braun, Hans-Bertram [4 ]
Pelloux, Herve [3 ,5 ]
机构
[1] CHU Nantes, Inst Biol, Lab Parasitol Mycol, F-44093 Nantes 1, France
[2] Univ Nantes, Nantes Atlantique Univ, Dept Parasitol & Mycol Med, IICiMED,EA 155, F-44093 Nantes 1, France
[3] CHU Grenoble, Lab Parasitol Mycol, Dept Agents Infect, F-38043 Grenoble 9, France
[4] Abbott GmbH & Co KG, D-65205 Wiesbaden, Germany
[5] Univ Grenoble 1, CNRS, Inst J Roget, Lab Adaptat & Pathogenie Microorganismes,UMR 5163, Grenoble 9, France
关键词
Toxoplasmosis; Toxoplasma gondii; Diagnosis; Serology; IgG; IgM; Avidity; Pregnant women; IMMUNOGLOBULIN-G IGG; TOXOPLASMA-GONDII INFECTION; DIAGNOSIS; MULTICENTER; MATURATION; TESTS;
D O I
10.1016/j.diagmicrobio.2009.07.013
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
We assessed the performance of the ARCHITECT Toxo IgG, IgM, and IgG Avidity assays against corresponding assays on AxSYM and Vidas using 730 sera from pregnant women. The ARCHITECT Toxo IgG and IgM assays showed a relative sensitivity of 97.5% and 89.9% and a relative specificity of 99.1% and 99.8%, respectively. If IgM sensitivity is calculated only for sera drawn less than 4 months after infection, the relative sensitivity rises to 98.1%. Correlation between the ARCHITECT and Vidas Avidity assays was 0.87 (n = 103). Testing 86 IgG-positive specimens from recent infection (<4 months), we never obtained high avidity results, but 2 specimens were in the gray zone, whereas sera from past infections (>4 months) exhibited high avidity results in 72.5% (137/189) of cases. The method can be used reliably to exclude recent infections in sera with concurrently positive results for IgM and IgG (IgG, >3 IU/mL). (C) 2009 Elsevier Inc. All rights reserved.
引用
收藏
页码:279 / 287
页数:9
相关论文
共 50 条
  • [41] A technique for dating toxoplasmosis in pregnancy and comparison with the Vidas anti-toxoplasma IgG avidity test
    Flori, P.
    Bellete, B.
    Crampe, C.
    Maudry, A.
    Patural, H.
    Chauleur, C.
    Hafid, J.
    Raberin, H.
    Sung, R. Tran Manh
    [J]. CLINICAL MICROBIOLOGY AND INFECTION, 2008, 14 (03) : 242 - 249
  • [42] IgG avidity assay: A tool for excluding acute toxoplasmosis in prolonged IgM titer sera from pregnant women
    Emelia, O.
    Rahana, A. R.
    Firdaus, Mohamad A.
    Cheng, H. S.
    Nursyairah, M. S.
    Fatinah, A. S.
    Azmawati, M. N.
    Siti, N. A. M.
    Aisah, M. Y.
    [J]. TROPICAL BIOMEDICINE, 2014, 31 (04) : 633 - 640
  • [43] Anti-Toxoplasma IgG assays: What performances for what purpose? A systematic review
    Robert-Gangneux, Florence
    Guegan, Helene
    [J]. PARASITE, 2021, 28
  • [44] DETECTION OF REAGINS,IGG,IGA AND IGM ANTIBODIES IN HUMAN SERA
    PARISH, WE
    [J]. INTERNATIONAL ARCHIVES OF ALLERGY AND APPLIED IMMUNOLOGY, 1969, 36 (03): : 245 - &
  • [45] Detection of anti-toxoplasma immunoglobulin M in pregnant women
    Pelloux, H
    FrickerHidalgo, H
    GoullierFleuret, A
    AmbroiseThomas, P
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1997, 35 (08) : 2187 - 2187
  • [46] ELISA METHOD (ENZYME-LINKED IMMUNOSORBENT-ASSAY) IN THE ANTI-TOXOPLASMA IGG AND IGM DETECTION
    BROCCHI, E
    GENZINI, E
    VALCAVI, P
    SCHITO, GC
    [J]. BOLLETTINO DELL ISTITUTO SIEROTERAPICO MILANESE, 1981, 60 (06): : 498 - 507
  • [47] Development of Fully Automated Determination of Marker-Specific Immunoglobulin G (IgG) Avidity Based on the Avidity Competition Assay Format: Application for Abbott Architect Cytomegalovirus and Toxo IgG Avidity Assays
    Curdt, Ingo
    Praast, Gerald
    Sickinger, Eva
    Schultess, Jan
    Herold, Iris
    Braun, Hans Bertram
    Bernhardt, Stephanie
    Maine, Gregory T.
    Smith, Darwin D.
    Hsu, Stephen
    Christ, Heike M.
    Pucci, Dominick
    Hausmann, Michael
    Herzogenrath, Joerg
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2009, 47 (03) : 603 - 613
  • [48] Clinical evaluation of automated cytomegalovirus IgG, IgM and IgG avidity assays for the LIAISON XL® analyser platform
    Pavia, C.
    Moroni, A.
    Chiereghin, A.
    Piccirilli, G.
    Gabrielli, L.
    Lazzarotto, T.
    [J]. JOURNAL OF CLINICAL VIROLOGY, 2015, 70 : S67 - S67
  • [49] COMPARISON OF THE RESULTS OF CMV IGG AVIDITY AND CMV Igm TESTS IN PREGNANT WOMEN
    Yucel, Aysegul
    Buyrukcu, Bugra Adil
    Bozdayi, Gulendam
    Rota, Seyyal
    [J]. GAZI MEDICAL JOURNAL, 2006, 17 (01): : 34 - 38
  • [50] ANTI-TOXOPLASMA GONDII IGG DETECTION IN SALIVA FOR TOXOPLASMOSIS EPIDEMIOLOGICAL STUDIES
    Sampaio, Barbara F.
    Andrade, Heitor Franco
    Meireles, Luciana Regina
    [J]. AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2015, 93 (04): : 349 - 349