Investigation of radiation doses in open space using TLD detectors

被引:10
|
作者
Reitz, G [1 ]
Facius, R
Bilski, P
Olko, P
机构
[1] DLR, Cologne, Germany
[2] Inst Nucl Phys, Krakow, Poland
关键词
D O I
10.1093/oxfordjournals.rpd.a005930
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The low energy component of the cosmic radiation field is strongly modified by the shielding of the spacecraft and it is time and location dependent. Thermoluminescent lithium fluoride detectors have been applied to determine the radiation doses inside the ESA-Facility BIOPAN. The BIOPAN facility was mounted outside and launched on a Felon spacecraft and opened to space to allow exposure of several experiments to open space. Standard TLD-600, TLD-700 chips, two layers MTS-Ns sintered pellets with different effective thickness of the sensitive layer and MTS-N of different thickness have been exposed with different shielding thicknesses in front of them. The Measured TL signal in the 0.1 mm thick detector just shielded by an aluminised Kapton foil of 25 mum thickness in front yielded a dose of 29.8 Gy (calibrated with Cs-137 gaming rays) for an exposure time of 12.7 days: after 2.5 g.cm(-2) shielding the doses dropped to 3 mGy. The monitoring of radiation doses and its depth dose distribution outside the spacecraft are of great interest for radiation protection of astronauts working in open space. The knowledge of depth-dose distribution is a prerequisite to determine the organ doses an astronaut will receive during an extravehicular activity (EVA). The BIOPAN experiments are to be continued in the future.
引用
收藏
页码:533 / 536
页数:4
相关论文
共 50 条
  • [1] Investigation of radiation doses in open space using TLD detectors
    Reitz, G
    Facius, R
    Bilski, P
    Olko, P
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : 533 - 536
  • [2] PROBLEMS IN DETERMINING RADIATION-DOSES ON BOARD OF SPACE STATIONS USING THERMOLUMINESCENT DETECTORS
    SCHMIDT, P
    DORSCHEL, B
    FELLINGER, J
    ZEITSCHRIFT FUR KLINISCHE MEDIZIN-ZKM, 1989, 44 (20): : 1729 - 1731
  • [3] Investigation of the Radiation Effect on BOTDR Under Low Space Radiation Doses
    Li, Mi
    Zhang, Yizhuo
    Chen, Zhang
    Zhang, Yuexing
    Song, Yuejiang
    Zhang, Xuping
    IEEE PHOTONICS JOURNAL, 2020, 12 (06):
  • [4] SPACE RADIATION-DOSIMETRY USING BUBBLE DETECTORS
    ING, H
    MORTIMER, A
    LIFE SCIENCES AND SPACE RESEARCH XXV(2): RADIATION BIOLOGY, 1994, 14 (10): : 73 - 76
  • [5] Investigation of Space Radiation-Induced Effects on the Performance of CCD Detectors Using Radiation Monitors In-Flight Measurements
    Serief, Chahira
    Meguenni, Mohammed
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2025, 72 (02) : 110 - 117
  • [6] RADIATION DETECTORS IN SPACE.
    Glasow, Peter
    Siemens review, 1986, 53 (05): : 36 - 38
  • [7] SATELLITE MEASUREMENTS OF SPACE RADIATION DOSES
    GLASS, RA
    GAINES, EE
    HOLLISTER, WL
    RADIATION RESEARCH, 1963, 19 (01) : 202 - &
  • [8] COMPARISON OF IN VIVO BRACHYTHERAPY DOSES EVALUATED USING TLD RODS AND TLD "PIN WORMS": A CASE STUDY
    Urbonavicius, Benas Gabrielis
    Jakstas, Karolis
    Adliene, Diana
    Ruzele, Paulius
    Kaskonas, Paulius
    MEDICAL PHYSICS IN THE BALTIC STATES, 2015, : 149 - 152
  • [9] Radiation tolerance investigation of XAMPS detectors
    Carini, G. A.
    Kuczewski, A. J.
    Siddons, D. P.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 474 - 476
  • [10] FURTHER STUDY ON THE TL STABILITY OF TLD-900 AT LOW RADIATION-DOSES
    FURETTA, C
    GENNAI, P
    RADIATION EFFECTS LETTERS, 1980, 57 (1-2): : 55 - 58