Co-Heating method for thermal performance evaluation of closed refrigerated display cabinets

被引:2
|
作者
Mansson, Tommie [1 ]
Kalagasidis, Angela Sasic [1 ]
Ostermeyer, York [1 ]
机构
[1] Chalmers Univ Technol, Bldg Technol Architecture & Civil Engn, Gothenburg, Sweden
关键词
Refrigerated display cabinet; Thermal performance; Experiment; Condensate; Co-Heating;
D O I
10.1016/j.ijrefrig.2020.10.011
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this study, an application of the adapted Co-Heating methodology for thermal performance evaluation of closed refrigerated display cabinets (RDCs) has been presented. A novel test series comprising three experiments has been developed and demonstrated on a commercial RDC with four doors to evaluate the envelope heat transfer coefficient, thermal inertia, infiltration at idle state and dynamic infiltration caused by door operations. The latter two experiments were conducted in parallel with the condensate collection method for validation of the results for infiltration. It was concluded with good (<10%) conformance between the methods that the infiltration at idle state for the tested RDC is approximately 0.022 kg/s and that one 15 s door opening causes approximately 0.94 kg of ambient indoor air to infiltrate. Additionally, the time, equipment and associated costs for running the tests were compared, and it was concluded that the adapted Co-Heating methodology could substitute the condensate collection method for the evaluation of infiltration while providing additional results on the thermal performance. (C) 2020 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/)
引用
收藏
页码:51 / 60
页数:10
相关论文
共 50 条
  • [1] PERFORMANCE EVALUATION METHOD OF CO2 HEAT PUMP DRIVEN REFRIGERATED DISPLAY CABINETS
    Redo, Mark Anthony
    Giannetti, Niccolo
    Tojo, Kenji
    Ohno, Keisuke
    Yamaguchi, Seiichi
    Saito, Kiyoshi
    [J]. 13TH IIR GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS: NATURAL REFRIGERANT SOLUTIONS FOR WARM CLIMATE COUNTRIES, 2018, : 1061 - 1068
  • [2] PERFORMANCE EVALUATION METHOD OF HEAT PUMP DRIVEN REFRIGERATED DISPLAY CABINETS
    Ohno, Keisuke
    Redo, Mark Anthony
    Giannetti, Niccolo
    Yamaguchi, Seiichi
    Saito, Kiyoshi
    [J]. 5TH IIR INTERNATIONAL CONFERENCE ON SUSTAINABILITY AND THE COLD CHAIN, 2018, : 294 - 301
  • [3] Seasonal performance evaluation of CO2 open refrigerated display cabinets
    Redo, Mark Anthony
    Ohno, Keisuke
    Giannetti, Niccolo
    Yamaguchi, Seiichi
    Saito, Kiyoshi
    [J]. APPLIED THERMAL ENGINEERING, 2019, 163
  • [4] CERTIFICATION OF PERFORMANCE OF REFRIGERATED DISPLAY CABINETS
    Marinhas, S.
    [J]. 23RD IIR INTERNATIONAL CONGRESS OF REFRIGERATION, 2011, 23 : 24 - 29
  • [5] Hygro-thermal model for estimation of demand response flexibility of closed refrigerated display cabinets
    Mansson, Tommie
    Kalagasidis, Angela Sasic
    Ostermeyer, York
    [J]. APPLIED ENERGY, 2021, 284
  • [6] Experimental and numerical investigation of the performance of retail refrigerated display cabinets
    Chaomuang, Nattawut
    Flick, Denis
    Laguerre, Onrawee
    [J]. TRENDS IN FOOD SCIENCE & TECHNOLOGY, 2017, 70 : 95 - 104
  • [7] The Design of the Performance Test Laboratory of Open Refrigerated Display Cabinets Based on Enthalpy Potential Method
    Li, Shuai
    Li, Lei
    [J]. PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON INTELLIGENT SYSTEMS RESEARCH AND MECHATRONICS ENGINEERING, 2015, 121 : 1599 - 1602
  • [8] THE DESIGN OF MEDICAL OPEN REFRIGERATED DISPLAY CABINETS LABORATORY WITH THE PERFORMANCE TEST
    Chen, J. B.
    Kong, X. S.
    [J]. BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2016, 118 : 114 - 114
  • [9] Thermal processing of silicon wafers with microwave co-heating
    Zohm, H
    Kasper, E
    Mehringer, P
    Müller, GA
    [J]. MICROELECTRONIC ENGINEERING, 2000, 54 (3-4) : 247 - 253
  • [10] Simulation of the performance of single jet air curtains for vertical refrigerated display cabinets
    Ge, YT
    Tassou, SA