Optical coherence tomography of macular thickness after biaxial vs coaxial microincision clear corneal cataract surgery

被引:8
|
作者
Kurz, Sabine [1 ]
Krummenauer, Frank [2 ]
Thieme, Hagen [1 ]
Dick, H. Burkhard [3 ]
机构
[1] Johannes Gutenberg Univ Mainz, Dept Ophthalmol, D-55101 Mainz, Germany
[2] Tech Univ Dresden, Clin Epidemiol & Hlth Econ Unit, Dresden, Germany
[3] Ruhr Univ Bochum, Dept Ophthalmol, Bochum, Germany
关键词
Biaxial phacoemulsification; Microincision cataract surgery; Optical coherence tomography; Retinal thickness; VISUAL-ACUITY; UNCOMPLICATED PHACOEMULSIFICATION; ULTRAHIGH-RESOLUTION; WOUND-TEMPERATURE; RETINAL THICKNESS; HOLE FORMATION; MM INCISION; EDEMA; WHITESTAR; MICROPHACOEMULSIFICATION;
D O I
10.1177/112067210901900615
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To evaluate macular thickness changes after biaxial microincision versus coaxial small incision cataract surgery using optical coherence tomography (OCT). METHODS. This prospective, randomized, marked study comprised 70 patients (70 eyes) undergoing biaxial microincision surgery or conventional coaxial phacoemulsification. Patients were evaluated by Stratus OCT preoperatively and 1 day, 4 weeks, and 8 weeks postoperatively. Best-corrected visual acuity (BCVA), phacoemulsification power, and effective phacoemulsification time (EPT) were evaluated. RESULTS. In the biaxial group, median foveal thickness changed from 160 mu m preoperatively to 168 mu m 8 weeks postoperatively (p=0.018), while median macular volume increased from 2.43 mm(3) to 2.57 mm(3) (p<0.001). In the coaxial group, median foveal thickness increased from 164 mu m preoperatively to 170 mu m 8 weeks postoperatively (p=0.082), while median macular volume changed from 2.45 mm(3) to 2.55 mm(3) (p<0.001). No significant differences in the intraindividual increase of foveal thickness and macular volume were found between groups at 8 weeks. A statistically significant difference between groups was found in median foveal thickness at day 1 postoperatively (p=0.027). No significant differences between groups in median macular volume were found at day 1 or at 4 and 8 weeks postoperatively. Median phacoemulsification power was 7.1% and EPT 2.4 seconds in the biaxial group versus 10.6% and 3.2 seconds in the coaxial group (p<0.001 and p=0.078). CONCLUSIONS. No clinically relevant differences in foveal thickness or macular volume were observed after biaxial microincision and coaxial small incision clear corneal cataract surgery. The blood-retinal barrier did not seem to be influenced by either procedure. (Eur J Ophthalmol 2009; 19: 990-7)
引用
收藏
页码:990 / 997
页数:8
相关论文
共 50 条
  • [1] Optical coherence tomography of macular thickness after cataract surgery
    Sourdille, P
    Santiago, PY
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (02): : 256 - 261
  • [2] Optical coherence tomography of clear corneal incisions for cataract surgery
    Schallhorn, Julie M.
    Tang, Maolong
    Li, Yan
    Song, Jonathan C.
    Huang, David
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (09): : 1561 - 1565
  • [3] Incisions for biaxial and coaxial microincision cataract surgery
    Mueller, M.
    Kohnen, T.
    [J]. OPHTHALMOLOGE, 2010, 107 (02): : 108 - +
  • [4] Macular thickness after uneventful cataract surgery determined by optical coherence tomography
    von Jagow, Burkhard
    Ohrloff, Christian
    Kohnen, Thomas
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2007, 245 (12) : 1765 - 1771
  • [5] Macular thickness after uneventful cataract surgery determined by optical coherence tomography
    Burkhard von Jagow
    Christian Ohrloff
    Thomas Kohnen
    [J]. Graefe's Archive for Clinical and Experimental Ophthalmology, 2007, 245 : 1765 - 1771
  • [6] Biaxial microincision versus coaxial small-incision clear cornea cataract surgery
    Kurz, Sabine
    Krummenauer, Frank
    Gabriel, Pia
    Pfeiffer, N.
    Dick, H. Burkhard
    [J]. OPHTHALMOLOGY, 2006, 113 (10) : 1818 - 1826
  • [7] Evaluation of macular thickness after uncomplicated cataract surgery using optical coherence tomography
    Giansanti, Fabrizio
    Bitossi, Alice
    Giacomelli, Giovanni
    Virgili, Gianni
    Pieretti, Giulia
    Giuntoli, Matteo
    Abbruzzese, Giacomo
    Menchini, Ugo
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2013, 23 (05) : 751 - 756
  • [8] Effect of biaxial versus coaxial microincision cataract surgery on optical quality of the cornea
    Eliwa, Tamer Fahmy
    Elsamkary, Mahmoud A.
    Hamza, Ismail
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2015, 63 (06) : 487 - 490
  • [9] Standard coaxial phaco vs microincision cataract surgery: a corneal endothelium study
    Franchini, Alessandro
    Frosini, Saverio
    Boddi, Vieri
    [J]. INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2008, 1 (04) : 344 - 350
  • [10] Anterior segment optical coherence tomography evaluation and comparison of main clear corneal incisions in microcoaxial and biaxial cataract surgery
    Can, Izzet
    Bayhan, Hasan Ali
    Celik, Hale
    Ceran, Basak Bostanci
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (03): : 490 - 500