Optical coherence tomography of clear corneal incisions for cataract surgery

被引:39
|
作者
Schallhorn, Julie M. [1 ,2 ]
Tang, Maolong [1 ,2 ]
Li, Yan [1 ,2 ,3 ]
Song, Jonathan C. [1 ,2 ]
Huang, David [1 ,2 ]
机构
[1] Univ So Calif, Keck Sch Med, Dept Ophthalmol, Los Angeles, CA 90033 USA
[2] Univ So Calif, Doheny Eye Inst, Los Angeles, CA 90033 USA
[3] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
来源
关键词
D O I
10.1016/j.jcrs.2008.05.026
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To study the architecture of clear corneal incisions for phacoemulsification cataract surgery using optical coherence tomography (OCT). SETTING: Doheny Eye Institute and Department of Ophthalmology, Keck School of Medicine of the University of Southern California, Los Angeles, California, USA. METHODS: This prospective study comprised 20 eyes of 20 patients 1 month after cataract surgery performed by 1 of 2 experienced surgeons. Temporal clear corneal single-plane incisions were made with 3.0 mm metal keratomes. Each eye was scanned before and 1 month after surgery with a prototype high-speed anterior segment OCT system (Carl Zeiss Meditec, Inc.). The OCT scans were repeated 3 times during the same visit. The length of the corneal incision, thickness of the cornea, and position of the incision (distance from external wound edge to scleral spur) were measured using a computer caliper, The angle of the incision relative to the corneal surface was then calculated. RESULTS: The mean corneal incision length was 1.81 mm +/- 0.27 (SD), the mean corneal thickness at the incision was 747 +/- 67 mu m, and the mean distance between the incision and the scleral spur was 1.46 +/- 0.24 mm. The mean angle of the incision was 26.8 +/- 5.5 degrees. The measurements were repeatable to within +/- 0.072 mm (pooled standard deviation) for the incision length, +/- 11 mu m for the corneal thickness, and 0.042 mm for the position of the incision. CONCLUSIONS: Optical coherence tomography allowed excellent evaluation of corneal incisions in cataract surgery postoperatively. Measurements of wound dimensions using OCT were highly repeatable.
引用
收藏
页码:1561 / 1565
页数:5
相关论文
共 50 条
  • [1] In-vitro optical coherence tomography of clear corneal cataract incisions
    Rao, B
    Zhang, J
    McDonnell, PJ
    Taban, M
    Chen, ZP
    [J]. LASERS IN SURGERY AND MEDICINE, 2003, : 4 - 4
  • [2] Visualizing morphological changes of clear corneal cataract incisions with optical coherence tomography
    Rao, B
    Zhang, J
    Taban, M
    McDonnell, PJ
    Chen, ZP
    [J]. OPHTHALMIC TECHNOLOGIES XIV, 2004, 5314 : 112 - 118
  • [3] Profile of clear corneal cataract incisions demonstrated by ocular coherence tomography
    Fine, I. Howard
    Hoffman, Richard S.
    Packer, Mark
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (01): : 94 - 97
  • [4] Anterior segment optical coherence tomography evaluation and comparison of main clear corneal incisions in microcoaxial and biaxial cataract surgery
    Can, Izzet
    Bayhan, Hasan Ali
    Celik, Hale
    Ceran, Basak Bostanci
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (03): : 490 - 500
  • [5] Architecture evaluation of the main clear corneal incisions in femtosecond laser-assisted cataract surgery by optical coherence tomography imaging
    Pereira Dias Chaves, Mario Augusto
    de Medeiros, Andre Lins
    Cortez Vilar, Cesar Martins
    Pereira Magalhaes, Klayne Rafaella
    Goncalves, Michelle Rodrigues
    de Moraes Tzelikis, Patrick Frenzel
    Hida, Wilson Takashi
    Carricondo, Pedro Carlos
    Alves, Milton Ruiz
    [J]. CLINICAL OPHTHALMOLOGY, 2019, 13 : 365 - 372
  • [6] Sealing clear corneal incisions in cataract surgery
    Kaur, Manpreet
    Tomar, Ankit
    Shaikh, Farin
    Falera, Ruchita
    Bageshwar, Lalit M. S.
    Titiyal, Jeewan S.
    [J]. EXPERT REVIEW OF OPHTHALMOLOGY, 2018, 13 (01) : 47 - 55
  • [7] Evaluation of Femtosecond Laser Versus Manual Clear Corneal Incisions in Cataract Surgery Using Spectral-Domain Optical Coherence Tomography
    Wang, Xiaogang
    Zhang, Zhe
    Li, Xiaoyan
    Xie, Lisha
    Zhang, Haining
    Koch, Douglas D.
    Wang, Li
    Zhang, Suhua
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2018, 34 (01) : 17 - 22
  • [8] Healing changes in clear corneal cataract incisions evaluated using Fourier-domain optical coherence tomography
    Wang, Li
    Dixit, Lena
    Weikert, Mitchell P.
    Jenkins, Richard B.
    Koch, Douglas D.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (04): : 660 - 665
  • [9] SUTURELESS CLEAR CORNEAL INCISIONS COMBINED WITH CORNEAL RELAXING INCISIONS IN CATARACT-SURGERY
    JOHNSON, DE
    GILLS, JP
    ROWSEY, JJ
    SANDERS, DR
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1994, 35 (04) : 1435 - 1435
  • [10] Imaging and investigating the effects of incision angle of clear corneal cataract surgery with optical coherence tomography
    Rao, B
    Zhang, J
    Taban, M
    McDonnell, PJ
    Chen, ZP
    [J]. OPTICS EXPRESS, 2003, 11 (24): : 3254 - 3261