Quantitative Elastography Versus Fine-needle Aspiration by Endoscopic Ultrasound for the Assessment of Pancreatic Solid Masses

被引:1
|
作者
Hernandez Mondragon, Oscar V. [1 ]
Velez Resendiz, Juan M. [2 ,3 ]
Ruiz, Rodolfo R. [4 ]
机构
[1] Natl Med Ctr Century XXI, Specialties Hosp, Div Endoscopy, Cuauhtemoc Ave 330, Mexico City 06700, DF, Mexico
[2] Med Univ, Natl Politech Inst, Nanomed Multidisciplinary Lab, Mexico City, DF, Mexico
[3] Med Univ, Natl Politech Inst, Cardiovasc Pharmacol Res & Grad Study Sect, Mexico City, DF, Mexico
[4] Natl Med Ctr Century XXI, Coordinat Res Hlth, Training Ctr Clin Invest, Mexico City, DF, Mexico
关键词
quantitative elastography; fine-needle aspiration; pancreatic solid masses; strain ratio; sensitivity; EUS-GUIDED FNA; DIFFERENTIAL-DIAGNOSIS; STRAIN RATIO; ACCURACY; ULTRASONOGRAPHY; LESIONS; BENIGN; YIELD;
D O I
10.1097/MCG.0000000000001017
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and Aims: Pancreatic solid masses (PSM) are difficult to assess; endoscopic ultrasound with fine-needle aspiration (FNA) enables tissue acquisition, but has high false-negative rates. Quantitative elastography (QE) predicts diagnosis on the basis of the strain ratio (SR). We aimed to compare both methods to evaluate PSM. Materials and Methods: This prospective study, carried out between January and December 2016, included suspected PSM cases; those with advanced disease and cystic components were excluded. Both procedures were performed; histologic information was obtained for the final diagnoses. Diagnostic tests and receiver-operating characteristic curve were calculated. PResults: We included 134 patients (53% women; mean, 53 +/- 16.2 y). The median tumor size was 30 (10 to 78) mm, with 69.4% and 30.6% malignant and benign tumors (median SR: 19.5 vs. 7.5; P=0.000), respectively, and 87% were pancreatic adenocarcinoma. QE with SR cutoff >= 10 showed similar parameters to FNA in both PSM types: sensitivity, 94% in both; specificity, 85% versus 87%; positive predictive value, 93% versus 94%; negative predictive value, 87% in both; and accuracy, 92% for malignant and sensitivity, 85% versus 87%; specificity, 94% in both; positive predictive value, 87% in both; negative predictive value, 93% versus 94%; and accuracy, 92% for benign. The area under the curve was 0.96 (P<0.000; 95% confidence interval, 0.940-0.995). New classifications on the basis of positive likelihood ratio were grouped as follows: A <= 8.7 (benign tumor); B >8.7 to <15.5 (indeterminate); and C >= 15.5 (malignant). Conclusions: QE has similar capacity to FNA in PSM evaluation. However, the former can be used potentially as a substitute of the latter in certain cases on the basis of these new SR cutoff-based classifications.
引用
收藏
页码:E261 / E268
页数:8
相关论文
共 50 条
  • [31] Endoscopic ultrasound guided fine-needle aspiration and biopsy of pancreatic cysts
    Girotra, Mohit
    Park, Walter G.
    [J]. TECHNIQUES IN GASTROINTESTINAL ENDOSCOPY, 2018, 20 (01) : 39 - 45
  • [32] Endoscopic ultrasound-guided fine-needle aspiration for the diagnosis of solid pancreatic masses: the impact on patient-management strategy
    Touchefeu, Y.
    Le Rhun, M.
    Coron, E.
    Alamdari, A.
    Heymann, M. F.
    Mosnier, J. F.
    Matysiak, T.
    Galmiche, J. P.
    [J]. ALIMENTARY PHARMACOLOGY & THERAPEUTICS, 2009, 30 (10) : 1070 - 1077
  • [33] Impact of inconclusive endoscopic ultrasound-guided fine-needle aspiration results in the management and outcome of patients with solid pancreatic masses
    Sun, Bo
    Yang, Xiujiang
    Ping, Bo
    He, Yiping
    Zhang, Zhaozhen
    [J]. DIGESTIVE ENDOSCOPY, 2015, 27 (01) : 130 - 136
  • [34] Endoscopic ultrasound guided fine needle aspiration versus endoscopic ultrasound guided fine needle biopsy in sampling pancreatic masses A meta-analysis
    Wang, Jing
    Zhao, Shulei
    Chen, Yong
    Jia, Ruzhen
    Zhang, Xiaohua
    [J]. MEDICINE, 2017, 96 (28)
  • [35] Assessment of endoscopic ultrasound guided fine needle aspiration biopsy in the evaluation of pancreatic masses.
    Harewood, GC
    Clain, JE
    Wang, KK
    Yacavone, RF
    Wiersema, MJ
    [J]. GASTROINTESTINAL ENDOSCOPY, 2000, 51 (04) : AB168 - AB168
  • [36] Cutting edge of endoscopic ultrasound-guided fine-needle aspiration for solid pancreatic lesions
    Takuya Ishikawa
    Kentaro Yamao
    Yasuyuki Mizutani
    Tadashi Iida
    Hiroki Kawashima
    [J]. Journal of Medical Ultrasonics, 2024, 51 : 209 - 217
  • [37] Cutting edge of endoscopic ultrasound-guided fine-needle aspiration for solid pancreatic lesions
    Ishikawa, Takuya
    Yamao, Kentaro
    Mizutani, Yasuyuki
    Iida, Tadashi
    Kawashima, Hiroki
    [J]. JOURNAL OF MEDICAL ULTRASONICS, 2024, 51 (02) : 209 - 217
  • [38] Endoscopic ultrasound-guided fine-needle aspiration in the evaluation of gallbladder masses
    Varadarajulu, S
    Eloubeidi, MA
    [J]. ENDOSCOPY, 2005, 37 (08) : 751 - 754
  • [39] Harmonic Contrast-Enhanced Endoscopic Ultrasonography for the Guidance of Fine-Needle Aspiration in Solid Pancreatic Masses
    Seicean, Andrada
    Badea, Radu
    Moldovan-Pop, Anca
    Vultur, Simona
    Botan, Emil Claudiu
    Zaharie, Teodor
    Saftoiu, Adrian
    Mocan, Teodora
    Iancu, Cornel
    Graur, Florin
    Sparchez, Zeno
    Seicean, Radu
    [J]. ULTRASCHALL IN DER MEDIZIN, 2017, 38 (02): : 174 - 182
  • [40] Endoscopic ultrasound elastography-guided fine needle aspiration for solid pancreatic lesions: Down but not out!
    Rai, Praveer
    [J]. INDIAN JOURNAL OF GASTROENTEROLOGY, 2024,