A fast, accurate, and automatic 2D-3D image registration for image-guided cranial radiosurgery

被引:81
|
作者
Fu, Dongshan [1 ]
Kuduvalli, Gopinath [1 ]
机构
[1] Accuray Incorp, Sunnyvale, CA 94089 USA
关键词
2D-3D image registration; x-ray images; pattern intensity; patient tracking; image-guided radiosurgery; cranial radiosurgery; CyberKnife((R));
D O I
10.1118/1.2903431
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The authors developed a fast and accurate two-dimensional (2D)-three-dimensional (3D) image registration method to perform precise initial patient setup and frequent detection and correction for patient movement during image-guided cranial radiosurgery treatment. In this method, an approximate geometric relationship is first established to decompose a 3D rigid transformation in the 3D patient coordinate into in-plane transformations and out-of-plane rotations in two orthogonal 2D projections. Digitally reconstructed radiographs are generated offline from a preoperative computed tomography volume prior to treatment and used as the reference for patient position. A multiphase framework is designed to register the digitally reconstructed radiographs with the x-ray images periodically acquired during patient setup and treatment. The registration in each projection is performed independently; the results in the two projections are then combined and converted to a 3D rigid transformation by 2D-3D geometric backprojection. The in-plane transformation and the out-of-plane rotation are estimated using different search methods, including multiresolution matching, steepest descent minimization, and one-dimensional search. Two similarity measures, optimized pattern intensity and sum of squared difference, are applied at different registration phases to optimize accuracy and computation speed. Various experiments on an anthropomorphic head-and-neck phantom showed that, using fiducial registration as a gold standard, the registration errors were 0.33 +/- 0.16 mm (s.d.) in overall translation and 0.29 degrees +/- 0.11 degrees (s.d.) in overall rotation. The total targeting errors were 0.34 +/- 0.16 mm (s.d.), 0.40 +/- 0.2 mm (s.d.), and 0.51 +/- 0.26 mm (s.d.) for the targets at the distances of 2, 6, and 10 cm from the rotation center, respectively. The computation time was less than 3 s on a computer with an Intel Pentium 3.0 GHz dual processor. (c) 2008 American Association of Physicists in Medicine.
引用
收藏
页码:2180 / 2194
页数:15
相关论文
共 50 条
  • [1] Assessment of spline-based 2D-3D registration for image-guided spine surgery
    Zhang, Xuan
    Zheng, Guoyan
    Langlotz, Frank
    Nolte, Lutz-Peter
    [J]. MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2006, 15 (03) : 193 - 199
  • [2] Automatic Masking for Robust 3D-2D Image Registration in Image-Guided Spine Surgery
    Ketcha, M. D.
    De Silva, T.
    Uneri, A.
    Kleinszig, G.
    Vogt, S.
    Wolinsky, J. -P.
    Siewerdsen, J. H.
    [J]. MEDICAL IMAGING 2016: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2016, 9786
  • [3] Augmented reality based on fast deformable 2D-3D registration for image guided surgery
    Scheuering, M
    Rezk-Salama, C
    Barfuss, H
    Schneider, A
    Greiner, G
    [J]. MEDICAL IMAGING 2002: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2002, 4681 : 436 - 445
  • [4] Fast 2D-3D point-based registration using GPU-based preprocessing for image-guided surgery
    Hong, Helen
    Kim, Kyehyun
    Park, Seongjin
    [J]. PROGRESS IN PATTERN RECOGNITION, IMAGE ANALYSIS AND APPLICATIONS, PROCEEDINGS, 2006, 4225 : 218 - 226
  • [5] Fast 2D-3D marker-based registration of CT and X-ray fluoroscopy images for image-guided surgery
    Hong, Helen
    Kim, Kyehyun
    Park, Sungjin
    [J]. MEDICAL IMAGING 2006: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2006, 6141
  • [6] Automatic and Fast Registration Method for Image-Guided Surgery
    Wen, Xi
    Wang, Hong
    Zhai, Weiming
    [J]. 2014 IEEE INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICINE (BIBM), 2014,
  • [7] Location constraint based 2D-3D registration of fluoroscopic images and CT volumes for image-guided EP procedures
    Liao, Rui
    Xu, Ning
    Sun, Yiyong
    [J]. MEDICAL IMAGING 2008: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, PTS 1 AND 2, 2008, 6918
  • [8] Progressive attenuation fields: Fast 2D-3D image registration without precomputation
    Rohlfing, T
    Russakoff, DB
    Denzler, J
    Maurer, CR
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2004, PT 1, PROCEEDINGS, 2004, 3216 : 631 - 638
  • [9] Progressive attenuation fields: Fast 2D-3D image registration without precomputation
    Rohlfing, T
    Russakoff, DB
    Denzler, J
    Mori, K
    Maurer, CR
    [J]. MEDICAL PHYSICS, 2005, 32 (09) : 2870 - 2880
  • [10] An Open Platform for 2D-3D Image Registration Experiments
    Balter, J.
    Long, Y.
    Folkerts, M.
    Sharp, G.
    Bortfeld, T.
    Fessler, J.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)