Measurement of coronary blood flow and flow reserve using magnetic resonance imaging

被引:30
|
作者
Grist, TM
Polzin, JA
Bianco, JA
Foo, TKF
Bernstein, MA
Mistretta, CM
机构
[1] UNIV WISCONSIN,SCH MED,DEPT RADIOL,MADISON,WI
[2] UNIV WISCONSIN,SCH MED,DEPT CARDIOL,MADISON,WI
[3] UNIV WISCONSIN,SCH MED,DEPT MED PHYS,MADISON,WI
[4] GEN ELECT MED SYST,MILWAUKEE,WI
关键词
magnetic resonance; coronary blood flow;
D O I
10.1159/000177314
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: It was the purpose of this study to demonstrate the feasibility of performing coronary artery flow and coronary flow reserve (CFR) measurements in normal human volunteers using a magnetic resonance (MR) phase contrast technique. Materials and Methods: Coronary flow rate, flow velocity, peak flow and CFR were determined at rest and during pharmacologically induced hyperemia in 10 healthy volunteers, The flow measurements were obtained during a single breath-hold by using a fast, prospectively gated, segmented k-space gradient-echo phase contrast acquisition with view sharing (FASTCARD PC) that was modified to improve sampling of the diastolic flow. Data were processed using the standard phase difference (PD) processing techniques as well as a new complex difference (CD) flow measurement method intended to improve the accuracy of flow measurements in small vessels. Results: Mean hyperemic flow velocity (40 +/- 16 cm/s) and blood flow (3.9 +/- 1.5 ml/s) rates differed significantly from resting velocity (13 +/- 6.6 cm/s) and flow (1.1 +/- 0.4 ml/s) measurements (p < 0.0001), PD methods consistently measured larger flow rates at rest (24% larger, p < 0.0005) and stress (29% larger, p < 0.0001), CFR, calculated as the ratio of the mean PD flows (4.7 +/- 2.8), was higher than CFR calculated as the ratio of mean CD flows (4.2 +/- 1.8); however, the differences did not reach statistical significance (p = 0.07). Flow measurements performed in adjacent slices of the same vessel correlated well (r = 0.88). Conclusions: Coronary flow and CFR measurements using the MR techniques are feasible and are similar to those reported in the literature for healthy volunteers.
引用
收藏
页码:80 / 89
页数:10
相关论文
共 50 条
  • [41] Assessment of coronary flow reserve with fast cine phase contrast magnetic resonance imaging: Comparison with measurement by Doppler guide wire
    Shibata, M
    Sakuma, H
    Isaka, N
    Takeda, K
    Higgins, CB
    Nakano, T
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 1999, 10 (04) : 563 - 568
  • [42] Assessment of coronary arterial restenosis with phase-contrast magnetic resonance imaging measurements of coronary flow reserve
    Hundley, WG
    Hillis, LD
    Hamilton, CA
    Applegate, RJ
    Herrington, DM
    Clarke, GD
    Braden, GA
    Thomas, MS
    Lange, RA
    Peshock, RM
    Link, KM
    CIRCULATION, 2000, 101 (20) : 2375 - 2381
  • [43] Blood Oxygen Level-Dependent Magnetic Resonance Imaging in Comparison to Fractional Flow Reserve for the Detection of Coronary Artery Stenosis
    Voehringer, Matthias
    Flewitt, Jacqueline A.
    Green, Jordin D.
    Tyberg, John V.
    Friedrich, Matthias G.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (10) : A284 - A284
  • [44] FRACTIONAL FLOW RESERVE CORRELATES WITH BLOOD OXYGEN LEVEL-DEPENDENT (BOLD) MAGNETIC RESONANCE IMAGING IN CORONARY ARTERY DISEASE
    Bernhardt, Peter
    Rottbauer, Wolfgang
    Woehrle, Jochen
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E1068 - E1068
  • [45] Measuring cerebral blood flow using magnetic resonance imaging techniques
    Calamante, F
    Thomas, DL
    Pell, GS
    Wiersma, J
    Turner, R
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1999, 19 (07): : 701 - 735
  • [46] THERMODILUTION FLOW MEASUREMENT UNDERESTIMATES CORONARY FLOW RESERVE
    ROSSEN, JD
    STENBERG, RG
    BRAUN, P
    MARCUS, ML
    WINNIFORD, MD
    CLINICAL RESEARCH, 1989, 37 (04): : A887 - A887
  • [47] MEASUREMENT OF TISSUE BLOOD-FLOW USING INTRAVASCULAR RELAXATION AGENTS AND MAGNETIC-RESONANCE-IMAGING
    GORE, JC
    MAJUMDAR, S
    MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (02) : 242 - 248
  • [48] MEASUREMENT OF ABSOLUTE EPICARDIAL CORONARY-ARTERY FLOW AND FLOW RESERVE WITH BREATH-HOLD CINE PHASE-CONTRAST MAGNETIC-RESONANCE-IMAGING
    CLARKE, GD
    ECKELS, R
    CHANEY, C
    SMITH, D
    DITTRICH, J
    HUNDLEY, WG
    NESSAIVER, M
    LI, HF
    PARKEY, RW
    PESHOCK, RM
    CIRCULATION, 1995, 91 (10) : 2627 - 2634
  • [49] Magnetic Resonance Perfusion or Fractional Flow Reserve in Coronary Disease REPLY
    Nagel, Eike
    Berry, Colin
    NEW ENGLAND JOURNAL OF MEDICINE, 2019, 381 (23): : 2277 - 2278
  • [50] VISUALIZATION AND MEASUREMENT OF FLOW WITH MAGNETIC-RESONANCE IMAGING
    BARTH, K
    DEIMLING, M
    FRITSCHY, P
    LENZ, G
    MULLER, E
    REINHARDT, ER
    BIOMEDIZINISCHE TECHNIK, 1985, 30 (1-2): : 12 - 17