A Robust Fractional-Order PID Controller Based Load Frequency Control Using Modified Hunger Games Search Optimizer

被引:20
|
作者
Fathy, Ahmed [1 ]
Yousri, Dalia [2 ]
Rezk, Hegazy [3 ,4 ]
Thanikanti, Sudhakar Babu [5 ]
Hasanien, Hany M. [6 ]
机构
[1] Jouf Univ, Fac Engn, Elect Engn Dept, Sakaka 42421, Saudi Arabia
[2] Fayoum Univ, Fac Engn, Dept Elect Engn, Al Fayyum 63514, Egypt
[3] Prince Sattam Bin Abdulaziz Univ, Coll Engn Wadi Addawaser, Al Kharj 11942, Saudi Arabia
[4] Minia Univ, Fac Engn, Elect Engn Dept, Al Minya 61519, Egypt
[5] Chaitanya Bharathi Inst Technol CBIT, Dept Elect & Elect Engn, Hyderabad 500075, India
[6] Ain Shams Univ, Fac Engn, Elect Power & Machines Dept, Cairo 11517, Egypt
关键词
multi-interconnected system; load frequency control; FOPID; hunger games search optimizer; renewable energy plants; AUTOMATIC-GENERATION CONTROL; MULTI-INTERCONNECTED PLANTS; DAMPED WAVE ALGORITHM; POWER-SYSTEMS; ELECTRIC VEHICLES; DESIGN; AGC;
D O I
10.3390/en15010361
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this article, a recent modified meta-heuristic optimizer named the modified hunger games search optimizer (MHGS) is developed to determine the optimal parameters of a fractional-order proportional integral derivative (FOPID) based load frequency controller (LFC). As an interconnected system's operation requires maintaining the tie-line power and frequency at their described values without permitting deviations in them, an enhanced optimizer is developed to identify the controllers' parameters efficiently and rapidly. Therefore, the non-uniform mutation operator is proposed to strengthen the diversity of the solutions and discover the search landscape of the basic hunger games search optimizer (HGS), aiming to provide a reliable approach. The considered fitness function is the integral time absolute error (ITAE) comprising the deviations in tie-line power and frequencies. The analysis is implemented in two networks: the 1st network comprises a photovoltaic (PV) plant connected to the thermal plant, and the 2nd network has four connected plants, which are PV, wind turbine (WT), and 2 thermal units with generation rate constraints and governor dead-band. Two different load disturbances are imposed for two studied systems: static and dynamic. The results of the proposed approach of MHGS are compared with the marine predators algorithm (MPA), artificial ecosystem based optimization (AEO), equilibrium optimizer (EO), and Runge-Kutta based optimizer (RUN), as well as movable damped wave algorithm (DMV) results. Moreover, the performance specifications of the time responses of frequencies and tie-line powers' violations comprising rise time, settling time, minimum/maximum setting values, overshoot, undershoot, and the peak level besides its duration are calculated. The proposed MHGS shows its reliability in providing the most efficient values for the FOPID controllers' parameters that achieve the lowest fitness of 0.89726 in a rapid decaying. Moreover, the MHGS based system becomes stable the most quickly as it has the shortest settling time and is well constructed as it has the smallest peak, overshoots at early times, and then the system becomes steady. The results confirmed the competence of the proposed MHGS in designing efficient FOPID-LFC controllers that guarantee reliable operation in case of load disturbances.
引用
收藏
页数:25
相关论文
共 50 条
  • [31] Robust Position Control of PMSM Using Fractional-Order Sliding Mode Controller
    Huang, Jiacai
    Li, Hongsheng
    Chen, YangQuan
    Xu, Qinghong
    ABSTRACT AND APPLIED ANALYSIS, 2012,
  • [32] Equilibrium optimizer-tuned cascade fractional-order 3DOF-PID controller in load frequency control of power system having renewable energy resource integrated
    Guha, Dipayan
    Roy, Provas K.
    Banerjee, Subrata
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2021, 31 (01)
  • [33] Fractional order PID controller for load frequency control in a deregulated hybrid power system using Aquila Optimization
    Gupta, Deepak Kumar
    Dei, Geetanjali
    Soni, Ankit Kumar
    V. Jha, Amitkumar
    Appasani, Bhargav
    Bizon, Nicu
    Srinivasulu, Avireni
    Nsengiyumva, Philibert
    RESULTS IN ENGINEERING, 2024, 23
  • [34] Enhanced MPPT-Based Fractional-Order PID for PV Systems Using Aquila Optimizer
    Tadj, Mohammed
    Chaib, Lakhdar
    Choucha, Abdelghani
    Aldaoudeyeh, Al-Motasem
    Fathy, Ahmed
    Rezk, Hegazy
    Louzazni, Mohamed
    El-Fergany, Attia
    MATHEMATICAL AND COMPUTATIONAL APPLICATIONS, 2023, 28 (05)
  • [35] Implementation of Fractional-Order PID Controller in an Industrial Distributed Control System
    El-Shafei, Mohamed A. K.
    El-Hawwary, Mohamed I.
    Emara, Hassan M.
    2017 14TH INTERNATIONAL MULTI-CONFERENCE ON SYSTEMS, SIGNALS & DEVICES (SSD), 2017, : 713 - 718
  • [36] Implementation of Simplified Fractional-Order PID Controller Based on Modified Oustaloup’s Recursive Filter
    Li J.
    Liu Y.
    Shan C.
    Dai C.
    Journal of Shanghai Jiaotong University (Science), 2020, 25 (01) : 44 - 50
  • [37] Optimal fractional order PID controller design using Ant Lion Optimizer
    Pradhan, Rosy
    Majhi, Santosh Kumar
    Pradhan, Jatin Kumar
    Pati, Bibhuti Bhusan
    AIN SHAMS ENGINEERING JOURNAL, 2020, 11 (02) : 281 - 291
  • [38] Grouped grey wolf optimizer based optimal passive fractional-order PID control of photovoltaic inverters
    Yang B.
    Shu H.-C.
    Zhu D.-N.
    Qiu D.-L.
    Yu T.
    Kongzhi yu Juece/Control and Decision, 2020, 35 (03): : 593 - 603
  • [39] Load Frequency Control with Considering Impact of Wind Turbine Using a Fractional PID Controller
    Nouri, Navid
    Zamani, Abbas Ali
    Barakati, S. Masoud
    2018 SMART GRID CONFERENCE (SGC), 2018, : 353 - +
  • [40] Analysis of grey wolf optimizer based fractional order PID controller in speed control of DC motor
    Agarwal, Jeetendra
    Parmar, Girish
    Gupta, Rajeev
    Sikander, Afzal