Validation of two-fluid boiling flow model on the DEBORA benchmark experimental data

被引:0
|
作者
Gajsek, Aljosa [1 ]
Koncar, Bostjan [1 ]
Tekavcic, Matej [1 ]
Prosek, Andrej [1 ]
机构
[1] Jozef Stefan Inst, Reactor Engn Div, Jamova Cesta 39, Ljubljana 1000, Slovenia
关键词
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this work simulations of 4 DEBORA experiments have been performed with ANSYS Fluent code in Eulerian two-fluid framework, using the standard wall boiling model. The cases varied by their inlet sub-cooling and consequently represented different boiling flow regimes. Temperature, void fraction, Sauter mean diameter and velocity profiles were compared with the experimental data. Preliminary analysis showed qualitatively good agreement of simulated-temperature and velocity profiles with DEBORA experiments, while more detailed study of boiling and inter-phase transfer parameters will be needed to better match the void fraction profiles and bubble diameter profiles. Mainly the simulated Sauter mean diameters also significantly over-estimated the measured values in the near-wall regions.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] CFD simulation of upward subcooled boiling flow of refrigerant-113 using the two-fluid model
    Chen, Erfeng
    Li, Yanzhong
    Cheng, Xianghua
    APPLIED THERMAL ENGINEERING, 2009, 29 (11-12) : 2508 - 2517
  • [22] A two-fluid model for two-phase flow in PEMFCs
    He, Guangli
    Ming, Pingwen
    Zhao, Zongchang
    Abudula, Abuliti
    Xiao, Yu
    JOURNAL OF POWER SOURCES, 2007, 163 (02) : 864 - 873
  • [23] Rethinking the two-fluid model of two-phase flow
    Clausse, Alejandro
    NUCLEAR ENGINEERING AND DESIGN, 2024, 425
  • [24] Benchmark DEBORA: Assessment of MCFD compared to high-pressure boiling pipe flow measurements
    Bois, G.
    Fillion, P.
    Francois, F.
    Burlot, A.
    Ali, A. Ben Hadj
    Khaware, A.
    Sanyal, J.
    Rehm, M.
    Farges, B.
    Vinauger, F.
    Ding, W.
    Gajsek, A.
    Tekavcic, M.
    Koncar, B.
    Le Corre, J. -m.
    Li, H.
    Harlin, R.
    Jaseliunaite, J.
    Baglietto, E.
    Brewster, R.
    Ding, A.
    Vlcek, D.
    Sato, Y.
    Xiong, J.
    Wang, H.
    Luo, H.
    Vyskocil, L.
    Hovi, V.
    INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2024, 179
  • [25] A fully conservative model for compressible two-fluid flow
    Wackers, J
    Koren, B
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN FLUIDS, 2005, 47 (10-11) : 1337 - 1343
  • [26] TWO-FLUID MODEL FOR PREDICTION OF WET STEAM FLOW
    Dykas, S.
    Wroblewski, W.
    10TH EUROPEAN CONFERENCE ON TURBOMACHINERY: FLUID DYNAMICS AND THERMODYNAMICS, 2013,
  • [27] Two-fluid model for adiabatic laminar bubbly flow
    Song, Q., 2001, Chemical Industry Press (52):
  • [28] A two-fluid thermally stable cooling flow model
    Cen, RY
    ASTROPHYSICAL JOURNAL, 2005, 620 (01): : 191 - 196
  • [29] Modeling of slug flow using the two-fluid model
    Cazarez-Candia, Octavio
    Benitez-Centeno, Omar Christian
    Moya-Acosta, Sara Lilia
    INGENIERIA HIDRAULICA EN MEXICO, 2008, 23 (01): : 113 - 125
  • [30] Validation of two-fluid model of urban traffic for arterial streets
    Jones, EG
    Farhat, W
    CALIBRATION AND VALIDATION OF SIMULATION MODELS 2004, 2004, (1876): : 132 - 141