Radiation exposure during endovascular aneurysm repair

被引:96
|
作者
Weerakkody, R. A. [1 ]
Walsh, S. R. [1 ]
Cousins, C. [2 ]
Goldstone, K. E. [3 ]
Tang, T. Y. [1 ]
Gaunt, M. E. [1 ]
机构
[1] Cambridge Univ Hosp NHS Fdn Trust, Addenbrookes Hosp, Dept Vasc Surg, Cambridge CB2 0QQ, England
[2] Cambridge Univ Hosp NHS Fdn Trust, Addenbrookes Hosp, Dept Intervent Radiol, Cambridge CB2 0QQ, England
[3] Cambridge Univ Hosp NHS Fdn Trust, Addenbrookes Hosp, Dept Med Phys, Cambridge CB2 0QQ, England
关键词
D O I
10.1002/bjs.6229
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Endovascular stent-grafting is an established option for the repair of abdominal aortic aneurysm (AAA) that can involve prolonged manipulation under radiological control. The aim was to determine the average radiation exposure sustained during endovascular aneurysm repair (EVAR) and the first year of postoperative surveillance. Methods: Prospective radiation dose data were recorded and used to calculate dose area product (DAP) values for 96 patients undergoing EVAR. The DAP data were then used to determine the entrance skin dose (ESD), an indicator of potential skin damage, and the effective dose, an indicator of long-term cancer risk, for each patient. Results: The median ESD during EVAR was 0.85 (interquartile range 0.51-3-74) Gy. The threshold for possible radiation-induced skin damage of 2 Gy was exceeded in 29 per cent: of procedures. The effective dose of radiation in the first year following EVAR was 79 mSv. Conclusion: Radiation doses administered during EVAR were higher than previously thought, with a potential risk of radiation-induced skin damage and later malignancy.
引用
收藏
页码:699 / 702
页数:4
相关论文
共 50 条
  • [31] Quality control during endovascular aneurysm repair
    Loftus, IM
    Thompson, MM
    Lennard, N
    Steele, S
    Smith, J
    Treharne, G
    Fishwick, G
    Bell, PRF
    BRITISH JOURNAL OF SURGERY, 1998, 85 (04) : 568 - 568
  • [32] Editor's Choice - Estimated Radiation Dose to the Operator During Endovascular Aneurysm Repair
    Harbron, Richard W.
    Abdelhalim, Mohamed A.
    Ainsbury, Elizabeth A.
    Eakins, Jonathan S.
    Modarai, Bijan
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2023, 66 (02) : 178 - 185
  • [33] Early In Vivo Analysis of an Endovascular Stapler during Endovascular Aneurysm Repair
    Murphy, Erin H.
    Arko, Frank R.
    VASCULAR, 2009, 17 : S105 - S110
  • [34] Regarding "Endovascular management of iliac rupture during endovascular aneurysm repair"
    Semel, Lawrence
    Zaman, Syed N.
    Carlin, Robert E.
    McGurrin, Mark A.
    Riley, J. Timothy
    JOURNAL OF VASCULAR SURGERY, 2010, 52 (02) : 533 - 533
  • [35] Totally Percutaneous Aneurysm Sac Embolization During Endovascular Aneurysm Repair
    Ferretto, Luca
    Irsara, Sandro
    JOURNAL OF ENDOVASCULAR THERAPY, 2017, 24 (01) : 68 - 71
  • [36] Endovascular aneurysm repair
    Lindholt, JS
    LANCET, 2004, 364 (9437): : 818 - 820
  • [37] Endovascular Aneurysm Repair
    Hong, Kee Chun
    Kim, Jang Yong
    Jeon, Yong Sun
    JOURNAL OF THE KOREAN MEDICAL ASSOCIATION, 2006, 49 (06): : 542 - 552
  • [38] Endovascular aneurysm repair
    Fujitani, RM
    WESTERN JOURNAL OF MEDICINE, 1998, 168 (01): : 35 - 36
  • [39] Measurement and Optimization of Patient Radiation Doses in Endovascular Aneurysm Repair
    Walsh, C.
    O'Callaghan, A.
    Moore, D.
    O'Neill, S.
    Madhavan, P.
    Colgan, M. P.
    Haider, S. N.
    O'Reilly, A.
    O'Reilly, G.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2012, 43 (05) : 534 - 539
  • [40] Radiation exposure during endovascular procedures
    Lekovic, Gregory P.
    Kim, Louis J.
    Gonzalez, L. Fernando
    Bice, Alden
    Albuquerque, Felipe C.
    McDougall, Cameron G.
    NEUROSURGERY, 2008, 63 (01) : 81 - 85