Experimental Investigation of the Transpired Solar Air Collectors and Metal Corrugated Packing Solar Air Collectors

被引:12
|
作者
Zheng, Wandong [1 ,3 ]
Zhang, Huan [1 ]
You, Shijun [1 ]
Fu, Yindan [1 ,2 ]
机构
[1] Tianjin Univ, Sch Environm Sci & Technol, Tianjin 300072, Peoples R China
[2] Tianjin Univ, Coll Management & Econ, Tianjin 300072, Peoples R China
[3] China Acad Bldg Res, State Key Lab Bldg Safety & Built Environm, Beijing 100013, Peoples R China
基金
中国博士后科学基金;
关键词
solar air collector; cold and severe cold regions; thermal performance; experimental study; THERMOHYDRAULIC PERFORMANCE; HEATERS; PLATE; FLOW;
D O I
10.3390/en10030302
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The thermal performance of three novel solar air collectors with perforating corrugated plate, slit-perforated plate, and corrugated packing were experimentally studied in this paper. Experiments were conducted in Tianjin to study the thermal and dynamic performance of the collectors in cold and severe cold regions. A chamber with a PID (Proportion Integration Differentiation) temperature controller was designed to control the inlet air temperature of the three collectors. Effects of radiation intensity, inlet air temperature, and flow rate on the thermal efficiency and outlet air temperature were experimentally studied. The results indicated that the thermal efficiency of the three collectors in severe cold regions could be much higher than 50% and the collector with perforating corrugated plate had the highest thermal efficiency. The inlet air flow rate had significant effects on the thermal comfort of buildings in cold and severe cold regions and it should be lower than 45 m(3)/h. The results indicated that the pressure drops of collectors with perforating corrugated plate were a little larger than the collectors with slit-perforated plate, but the thermal efficiency and outlet air temperature was higher. Therefore, the collector with perforating corrugated plate was more suitable to use in cold and severe cold regions.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Testing solar air-heating collectors
    Kramer, Korbinian S.
    Thoma, Christoph
    Mehnert, Stefan
    Fahr, Sven
    [J]. PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON SOLAR HEATING AND COOLING FOR BUILDINGS AND INDUSTRY (SHC 2013), 2014, 48 : 137 - 144
  • [22] NEW INVESTIGATIONS IN SOLAR AIR HEATING COLLECTORS
    Ruskis, Guntis
    Aboltins, Aivars
    Palabinskis, Janis
    [J]. 11TH INTERNATIONAL SCIENTIFIC CONFERENCE ON ENGINEERING FOR RURAL DEVELOPMENT, VOL 11, 2012, : 527 - 531
  • [23] BARE-PLATE SOLAR AIR COLLECTORS
    不详
    [J]. ENERGY ENGINEERING, 1983, 80 (05) : 34 - 35
  • [24] Solar air heaters with two collectors in series
    Yeh, HM
    Lin, TT
    [J]. ENERGY, 1997, 22 (09) : 933 - 936
  • [25] Development of solar air collectors for drying applications
    Karim, MA
    Hawlader, MNA
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2004, 45 (03) : 329 - 344
  • [26] EXPERIMENTATION OF SOLAR AIR COLLECTORS WITH POROUS ABSORBERS
    RAUZIER, E
    [J]. REVUE DE PHYSIQUE APPLIQUEE, 1980, 15 (03): : 411 - 415
  • [27] AGRICULTURAL SOLAR AIR COLLECTORS - DESIGN AND PERFORMANCES
    FOHR, JP
    FIGUEIREDO, AR
    [J]. SOLAR ENERGY, 1987, 38 (05) : 311 - 321
  • [28] Application of folded sheet metal in flat bed solar air collectors
    El-Sawi, A. M.
    Wifi, A. S.
    Younan, M. Y.
    Elsayed, E. A.
    Basily, B. B.
    [J]. APPLIED THERMAL ENGINEERING, 2010, 30 (8-9) : 864 - 871
  • [29] Comparative study on the performances of solar air collectors with trapezoidal corrugated and flat absorber plates
    Selçuk Darici
    Anil Kilic
    [J]. Heat and Mass Transfer, 2020, 56 : 1833 - 1843
  • [30] Efficiency of Recycling Double-Pass V-Corrugated Solar Air Collectors
    Ho, Chii-Dong
    Hsiao, Ching-Fang
    Chang, Hsuan
    Tien, Yi-En
    Hong, Zih-Syuan
    [J]. ENERGIES, 2017, 10 (07):