Risk factors for loosening of cemented glenoid components in anatomical shoulder arthroplasty

被引:0
|
作者
Raiss, Patric [1 ]
Loew, Markus [2 ]
Bruckner, Thomas [3 ]
Favard, Luc [4 ]
Boileau, Pascal [5 ]
Walch, Gilles [6 ]
机构
[1] OCM Klin Munchen, Steinerstr 6, D-81369 Munich, Germany
[2] ATOS Clin Heidelberg, Dept Shoulder & Elbow Surg, Heidelberg, Germany
[3] Heidelberg Univ, Inst Med Biometry & Informat, Heidelberg, Germany
[4] CHU Trousseau, Orthopedie 1, Tours, France
[5] Hop Pasteur 2, Nice, France
[6] Ctr Orthoped Santy, Lyon, France
关键词
Shoulder arthroplasty; Reaming; Arthroplasty; Glenohumeral mismatch; Shoulder replacement; PRIMARY OSTEOARTHRITIS; FLAT-BACK; BONE; MULTICENTER; FAILURE;
D O I
10.1007/s11678-019-0535-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction Several risk factors leading to loosening of the glenoid have been described; however, there is no detailed information available on the exact numbers or percentages for each patient-related risk factor, implant-related risk factor, or risk factors related to surgical technique. Therefore, the aim of this multicenter study was to analyze these risk factors in a large cohort of patients treated with a 3rd-generation cemented total shoulder arthroplasty. Methods Four-hundred seventy-one shoulder arthroplasties with a mean follow-up of 8.1 years were included. There were 318 women and 153 men. The mean age at the time of arthroplasty was 68 (range 35-90) years. The dominant shoulder was treated in 294 cases and the nondominant in 177. The following risk factors for loosening of the cemented keeled glenoid component were examined: gender, age, hand dominance, glenoid morphology, reaming on the glenoid side (reaming down the complete subchondral bone layer), glenohumeral mismatch, glenoid component design, and fatty degeneration of the rotator cuff. Results No influence on radiographic glenoid loosening was found for patient age at surgery, gender, hand dominance, preparation technique on the glenoid side, or fatty degeneration of the rotator cuff (p> 0.067). Excessive reaming on the native glenoid led to a 3.7-fold higher risk for glenoid component loosening (p< 0.001). A glenohumeral mismatch <6mm was associated with higher radiographic loosening rates (p< 0.03). The use of a flat-back glenoid component led to a 3.1-fold higher risk for radiographic loosening compared to convex-back glenoids (p< 0.001). B2 glenoids had a higher risk for radiographic loosening compared to A1 (2.3-fold), A2 (3.6-fold), and B1 (2.7-fold) glenoids (p< 0.001). Conclusion Based on a large and homogenous cohort of patients, this study has shown several risk factors for loosening of a cemented glenoid component in the midterm and long term. The loosening rates of cemented keeled glenoid components in primary osteoarthritis could possibly be reduced by optimizing surgical technique, implant configuration, and patient selection. Further long-term studies are necessary to confirm these findings.
引用
收藏
页码:197 / 201
页数:5
相关论文
共 50 条
  • [1] Factors affecting cemented glenoid component loosening in total shoulder arthroplasty
    Szabo, Istvan
    Walch, Gilles
    [J]. INTERNATIONAL JOURNAL OF SHOULDER SURGERY, 2007, 1 (01): : 23 - 29
  • [2] Risk factors for loosening of cemented glenoid components in anatomical shoulder arthroplasty; [Risikofaktoren für die Glenoidlockerung zementierter Pfannen in der anatomischen Schulterendoprothetik]
    Raiss P.
    Loew M.
    Bruckner T.
    Favard L.
    Boileau P.
    Walch G.
    [J]. Obere Extremität, 2019, 14 (3) : 197 - 201
  • [3] Can convertible metal-backed glenoid components replace cemented polyethylene glenoid components in anatomical total shoulder arthroplasty?
    Myung-Sun Kim
    Yeong-Seub Ahn
    Sun-Ho Lee
    Hyeon Jang Jeong
    Young Kyu Kim
    Joo Han Oh
    [J]. BMC Surgery, 23
  • [4] Can convertible metal-backed glenoid components replace cemented polyethylene glenoid components in anatomical total shoulder arthroplasty?
    Kim, Myung-Sun
    Ahn, Yeong-Seub
    Lee, Sun-Ho
    Jeong, Hyeon Jang
    Kim, Young Kyu
    Oh, Joo Han
    [J]. BMC SURGERY, 2023, 23 (01)
  • [5] Glenoid loosening and failure in anatomical total shoulder arthroplasty: is revision with a reverse shoulder arthroplasty a reliable option?
    Melis, Barbara
    Bonnevialle, Nicolas
    Neyton, Lionel
    Levigne, Christophe
    Favard, Luc
    Walch, Gilles
    Boileau, Pascal
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2012, 21 (03) : 342 - 349
  • [6] Loosening rates of cemented, pegged glenoid components in total shoulder arthroplasty before and after change of type of cement and radius of glenoid curvature
    Hasler, Anita
    Dietrich, Tobias
    Farshad, Mazda
    Gerber, Christian
    [J]. SWISS MEDICAL WEEKLY, 2015, 145 : 34S - 34S
  • [7] Unacceptably high loosening and revision rate after anatomical total shoulder arthroplasty with cemented pegged polyethylene glenoid component
    Kraus, Moritz
    Illner, Johanna
    Audige, Laurent
    Scheibel, Markus
    [J]. SWISS MEDICAL WEEKLY, 2023, 153 : 64S - 65S
  • [8] Glenoid loosening and migration in reverse shoulder arthroplasty
    Laedermann, A.
    Schwitzguebel, A. J.
    Edwards, T. B.
    Godeneche, A.
    Favard, L.
    Walch, G.
    Sirveaux, F.
    Boileau, P.
    Gerber, C.
    [J]. BONE & JOINT JOURNAL, 2019, 101B (04): : 461 - 469
  • [9] Glenoid Loosening and Migration in Reverse Shoulder Arthroplasty
    Ladermann, Alexandre
    Schwitzguebel, Adrien
    Walch, Gilles
    Gerber, Christian
    [J]. SWISS MEDICAL WEEKLY, 2015, 145 : 33S - 34S
  • [10] Revision shoulder arthroplasty for glenoid component loosening
    Cheung, Emilie V.
    Sperling, John W.
    Cofield, Robert H.
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2008, 17 (03) : 371 - 375