Early glaucoma detection using the Humphrey Matrix perimeter, GDx VCC, stratus OCT, and retinal nerve fiber layer photography

被引:41
|
作者
Hong, Samin [1 ]
Ahn, Hyunseok [1 ]
Ha, Seung Joo [1 ]
Yeom, Ho Yeop [1 ]
Seong, Gong Je [1 ]
Hong, Young Jae [1 ]
机构
[1] Yonsei Univ, Coll Med, Dept Ophthalmol, Inst Vis Res, Seoul 120752, South Korea
关键词
D O I
10.1016/j.ophtha.2006.09.021
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the effectiveness of Humphrey Matrix perimetry, GDx VCC, Stratus OCT, and retinal nerve fiber layer (RNFL) photography using the Heidelberg Retina Angiograph 1 (HRA1) for early glaucoma detection. Design: Cross-sectional comparative study. Participants: Seventy-two primary open-angle glaucoma patients with early-stage visual field defects and 48 healthy controls were included. Methods: Measurements using Humphrey Matrix perimetry, GDx VCC, Stratus OCT, and RNFL photography using HRA1, as well as standard automated perimetry, were obtained. We constructed receiver operating characteristic (ROC) curves for all available parameters and calculated the area under the ROC curves (AUC) to seek the best discriminating parameter of each test. Subsequently, the ROC curves were calculated for the combinations of the best discriminating parameters of each test to seek the most effective combination for early glaucoma detection. Main Outcome Measure: The AUC for various parameters of Humphrey Matrix perimetry, GDx VCC, Stratus OCT, and RNFL photography using HRA1. Results: The AUCs of Humphrey Matrix perimetry, GDx VCC, Stratus OCT, and RNFL photography using HRA1 with the best discriminating parameter were 0.990, 0.906, 0.794, and 0.751, respectively. The AUC of the following best combination was 0.972, more than 5 points depressed below the level of 5% on the pattern deviation plot from Humphrey Matrix perimetry, and the nerve fiber indicator was larger than 20 from GDx VCC. Conclusions: The AUC of the Humphrey Matrix perimetry was greater than that of the GDx VCC, Stratus OCT, and RNFL photography using HRA1.
引用
收藏
页码:210 / 215
页数:6
相关论文
共 50 条
  • [31] Assessment of peripapillary retinal nerve fiber layer thickness using scanning laser polarimetry (GDx VCC) in normal Indian children
    Khamar, Mayuri B.
    Vasavada, Vaishali
    Shah, Sajani K.
    Trivedi, Rupal H.
    Thomas, Ravi
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2013, 61 (12) : 728 - 733
  • [32] Comparison of the OCT fast retinal nerve fiber layer thickness and fast optic disc algorithms for detection of early glaucoma
    Manassakorn, A
    Nouri-Mahdavi, K
    Caprioli, J
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [33] Peripapillary Retinal Nerve Fiber Layer Thickness Analysis With Scanning Laser Polarimetry (GDx VCC) in Normal Children
    Salvetat, Maria Letizia
    Zeppieri, Marco
    Felletti, Mirella
    Parisi, Lucia
    Brusini, Paolo
    [J]. JOURNAL OF GLAUCOMA, 2010, 19 (01) : 51 - 57
  • [34] Retinal Blood Vessel Distribution Correlates With the Peripapillary Retinal Nerve Fiber Layer Thickness Profile as Measured With GDx VCC and ECC
    Resch, Hemma
    Pereira, Ivania
    Weber, Stephanie
    Holzer, Stephan
    Fischer, Georg
    Vass, Clemens
    [J]. JOURNAL OF GLAUCOMA, 2015, 24 (05) : 389 - 395
  • [35] Intersession reproducibility of retinal nerve fiber layer thickness measurements by GDx-VCC in healthy and glaucomatous eyes
    Iacono, Pierluigi
    Da Pozzo, Stefano
    Fuser, Mirko
    Marchesan, Roberta
    Ravalico, Giuseppe
    [J]. OPHTHALMOLOGICA, 2006, 220 (04) : 266 - 271
  • [36] Detection of retinal nerve fiber layer defects on retinal fundus images for early diagnosis of glaucoma
    Muramatsu, Chisako
    Hayashi, Yoshinori
    Sawada, Akira
    Hatanaka, Yuji
    Hara, Takeshi
    Yamamoto, Tetsuya
    Fujita, Hiroshi
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2010, 15 (01)
  • [37] CORRELATION BETWEEN THE RETINAL NERVE FIBRE LAYER (RNFL) PARAMETERS MEASURED USING STRATUS OPTICAL COHERENCE TOMOGRAPHY AND GDx VCC (SCANNING LASER POLARIMETRY) IN ESTABLISHED GLAUCOMA PATIENTS IN SOUTH INDIAN POPULATION
    Suma, Elangovan
    Sanjeev, Puri K.
    [J]. INTERNATIONAL JOURNAL OF MEDICAL RESEARCH & HEALTH SCIENCES, 2013, 2 (03): : 603 - 608
  • [38] Relationship of brain MRI measures and retinal nerve fiber layer thickness, as assessed by OCT and GDx
    Zivadinov, R.
    Frohman, T.
    Cox, J. L.
    Dwyer, M. G.
    Hossein, S.
    Salter, A.
    Conger, A.
    Frohman, E. M.
    [J]. MULTIPLE SCLEROSIS, 2007, 13 : S85 - S86
  • [39] Influence of pupil size and cataract on retinal nerve fiber layer thickness measurements by stratus OCT
    Savini, Giacomo
    Zanini, Maurizio
    Barboni, Piero
    [J]. JOURNAL OF GLAUCOMA, 2006, 15 (04) : 336 - 340
  • [40] Comparison of scanning laser polarimetry using variable corneal compensation and retinal nerve fiber layer photography for detection of glaucoma
    Medeiros, FA
    Zangwill, LM
    Bowd, C
    Mohammadi, K
    Weinreb, RN
    [J]. ARCHIVES OF OPHTHALMOLOGY, 2004, 122 (05) : 698 - 704